Literature DB >> 2726600

Complex congenital cardiovascular anomalies evaluated by continuous-rotation computed tomography in children.

T Yamada1, J Harada, S Tada.   

Abstract

The slip ring and nutate/rotate configuration of the new, fourth-generation, computed tomography (CT) (TCT-900S, Toshiba Medical Company) makes it possible to scan consecutively 25 slices every 75 s. This scanner also rapidly provides hemodynamic and multiplanar reconstruction images. Studies were performed on 13 children with various forms of complex congenital cardiovascular anomalies. The findings correlated very well with those by angiocardiography and echocardiography. But the cardiac valves were difficult to scan, and combined use with echocardiography was considered to be indispensable. The rapid multiplanar reconstruction imaging is very effective in depicting coarctation of the aortic isthmus, ductus arteriosus, and hypoplasia of the great arteries in newborns and infants who have small target regions. Cine-displays of such images can clearly show ventricular and atrial septal defects. This new CT system proved effective in diagnosing complex congenital cardiovascular anomalies even in young infants.

Entities:  

Mesh:

Year:  1989        PMID: 2726600     DOI: 10.1007/BF02309917

Source DB:  PubMed          Journal:  Pediatr Cardiol        ISSN: 0172-0643            Impact factor:   1.655


  9 in total

1.  Computed tomography in congenital heart disease.

Authors:  D W Farmer; M J Lipton; W R Webb; H Ringertz; C B Higgins
Journal:  J Comput Assist Tomogr       Date:  1984-08       Impact factor: 1.826

2.  Left and right ventricular morphology in complex congenital heart disease defined by two dimensional echocardiography.

Authors:  R Foale; L Stefanini; A Rickards; J Somerville
Journal:  Am J Cardiol       Date:  1982-01       Impact factor: 2.778

3.  Congenital heart malformations: sequential angiographic analysis.

Authors:  J G Arciniegas; B Soto; H C Coghlan; L M Bargeron
Journal:  AJR Am J Roentgenol       Date:  1981-10       Impact factor: 3.959

4.  Cross-sectional echocardiographic assessment of coarctation in the sick neonate and infant.

Authors:  J F Smallhorn; J C Huhta; P A Adams; R H Anderson; J L Wilkinson; F J Macartney
Journal:  Br Heart J       Date:  1983-10

5.  Coarctation of the aorta: MR imaging.

Authors:  G K von Schulthess; S M Higashino; S S Higgins; D Didier; M R Fisher; C B Higgins
Journal:  Radiology       Date:  1986-02       Impact factor: 11.105

6.  Congenital heart disease: gated MR imaging in 72 patients.

Authors:  D Didier; C B Higgins; M R Fisher; L Osaki; N H Silverman; M D Cheitlin
Journal:  Radiology       Date:  1986-01       Impact factor: 11.105

7.  Two-dimensional echocardiographic assessment of dextrocardia: a segmental approach.

Authors:  J C Huhta; D J Hagler; J B Seward; A J Tajik; P R Julsrud; D G Ritter
Journal:  Am J Cardiol       Date:  1982-12       Impact factor: 2.778

8.  Gated magnetic resonance imaging of congenital cardiac malformations.

Authors:  B D Fletcher; M D Jacobstein; A D Nelson; T A Riemenschneider; R J Alfidi
Journal:  Radiology       Date:  1984-01       Impact factor: 11.105

9.  Evaluation of coarctation of the aorta by computed tomography.

Authors:  J D Godwin; R J Herfkens; B H Brundage; M J Lipton
Journal:  J Comput Assist Tomogr       Date:  1981-04       Impact factor: 1.826

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.