Optimization of Centrifugal Pump Characteristic Dimensions for Mechanical Circulatory Support Devices.

Theodosios Korakianitis1, Mohammad A Rezaienia, Gordon M Paul, Akbar Rahideh, Martin T Rothman, Sahand Mozafari.   

Abstract

The application of artificial mechanical pumps as heart assist devices impose power and size limitations on the pumping mechanism, and therefore requires careful optimization of pump characteristics. Typically new pumps are designed by relying on the performance of other previously designed pumps of known performance using concepts of fluid dynamic similarity. Such data are readily available for industrial pumps, which operate in Reynolds numbers region of 10. Heart assist pumps operate in Reynolds numbers of 10. There are few data available for the design of centrifugal pumps in this characteristic range. This article develops specific speed versus specific diameter graphs suitable for the design and optimization of these smaller centrifugal pumps concentrating in dimensions suitable for ventricular assist devices (VADs) and mechanical circulatory support (MCS) devices. A combination of experimental and numerical techniques was used to measure and analyze the performance of 100 optimized pumps designed for this application. The data are presented in the traditional Cordier diagram of nondimensional specific speed versus specific diameter. Using these data, nine efficient designs were selected to be manufactured and tested in different operating conditions of flow, pressure, and rotational speed. The nondimensional results presented in this article enable preliminary design of centrifugal pumps for VADs and MCS devices.

Mesh:

Year:  2016        PMID: 27258221     DOI: 10.1097/MAT.0000000000000393

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  3 in total

1.  Hemolytic Performance in Two Generations of the Sputnik Left Ventricular Assist Device: A Combined Numerical and Experimental Study.

Authors:  Alexandra N Romanova; Alexander A Pugovkin; Maxim V Denisov; Ivan A Ephimov; Dmitry V Gusev; Marian Walter; Thomas Groth; Olga L Bockeria; Tatyana G Le; Anna S Satyukova; Sergey V Selishchev; Dmitry V Telyshev
Journal:  J Funct Biomater       Date:  2022-01-12

2.  Optimization of Axial Pump Characteristic Dimensions and Induced Hemolysis for Mechanical Circulatory Support Devices.

Authors:  Theodosios Korakianitis; Mohammad Amin Rezaienia; Gordon Paul; Eldad Avital; Martin Rothman; Sahand Mozafari
Journal:  ASAIO J       Date:  2018 Nov/Dec       Impact factor: 2.872

3.  Computational Parametric Study of the Axial and Radial Clearances in a Centrifugal Rotary Blood Pump.

Authors:  Mohammad Amin Rezaienia; Gordon Paul; Eldad Avital; Martin Rothman; Theodosios Korakianitis
Journal:  ASAIO J       Date:  2018 Sep/Oct       Impact factor: 2.872

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.