Literature DB >> 27257881

Comparison between Dual Arc VMAT and 7F-IMRT in the protection of hippocampus for patients during whole brain radiotherapy.

Jun Li1,2,3, Xiao-Bin Tang1,3, Bu-Hai Wang2,4, Xue-Mei Chen2, Da Chen1,3, Lei Chai1,3.   

Abstract

PURPOSE: The purpose of this study was to compare the dosimetric characteristics for protection of the hippocampus between dual arc VMAT (volumetric modulated arc therapy) and 7 fields intensity-modulated radiation therapy (7F-IMRT) for patients with brain metastases from lung cancer under the whole brain radiotherapy.
METHODS: Based on ten cases with brain metastases from lung cancer, two types of radiotherapy plans were designed, namely, dual arc VMAT and 7F-IMRT. Provided that the clinical requirements were satisfied, the comparisons of target dose distribution, conformity index (CI), homogeneity index (HI), dose of organs at risk (OARs), monitor units (MU) and treatment time between dual arc VMAT and 7F-IMRT were investigated for their dosimetric difference.
RESULTS: Both treatment plans met the requirements of clinical treatments. However, the PTV-HA conformity and homogeneity of dual arc VMAT were superior to those of 7F-IMRT (P < 0.05). As to OARs, the mean maximum doses (Dmax) of hippocampus, eyes and optic nerves in the dual arc VMAT plan were all lower than those in 7F-IMRT plan (P < 0.05), but the result had no statistical significance (P < 0.05) for the maximum dose of lens. Compared with 7F-IMRT, dual arc VMAT reduced the average number of MU by 67% and the average treatment time by 74%. Therefore, treatment time was shortened by dual arc VMAT.
CONCLUSION: With regards to the patients with brain metastases from lung cancer under the whole brain radiotherapy, the PTV-HA conformity and homogeneity of dual arc VMAT were superior to those of 7F-IMRT under the precise of meeting the clinical requirements. In addition, dual arc VMAT remarkably reduced the irradiation dose to OARs (hippocampus, eyes and optic nerves), MU and treatment time, as well, guaranteed patients with better protection.

Entities:  

Keywords:  7F-IMRT; Brain metastases from lung cancer; dosimetry parameter comparison; dual arc VMAT; hippocampus protection

Mesh:

Year:  2016        PMID: 27257881     DOI: 10.3233/XST-160561

Source DB:  PubMed          Journal:  J Xray Sci Technol        ISSN: 0895-3996            Impact factor:   1.535


  2 in total

1.  Non-coplanar VMAT plans for postoperative primary brain tumour to reduce dose to hippocampus, temporal lobe and cochlea: a planning study.

Authors:  Eva Yi Wah Cheung; Kevin Ho Yuen Lee; Wilson Tin Long Lau; Amy Pik Yan Lau; Pak Ying Wat
Journal:  BJR Open       Date:  2021-07-05

2.  Evaluation of Hybrid Arc and Volumetric-Modulated Arc Therapy Treatment Plans for Fractionated Stereotactic Intracranial Radiotherapy.

Authors:  Jun Li; David To; Vickie Gunn; Wenyin Shi; Yan Yu; Haisong Liu
Journal:  Technol Cancer Res Treat       Date:  2018-01-01
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.