Bone Quality at the Sites of Loosened Screws in Mandibular Reconstruction Plates.

Takashi Nuri1, Koichi Ueda1, Masashi Okada1, Yuki Otsuki1, Hiroyuki Iwanaga1.   

Abstract

Entities:  

Year:  2016        PMID: 27257589      PMCID: PMC4874303          DOI: 10.1097/GOX.0000000000000646

Source DB:  PubMed          Journal:  Plast Reconstr Surg Glob Open        ISSN: 2169-7574


× No keyword cloud information.

Sir,

Although the osteocutaneous free flap is the best choice for mandibular reconstruction, it cannot be chosen sometimes because of the patient’s condition. Then, a metal reconstruction plate is chosen. However, some complications associated are reported.[1-3] Plate exposure is the most common complication. Another complication is dislocation of the plate caused by loosening of the screws. The dislocation may cause plate exposure. We believe loosening of the screws is affected by the quality of mandibular bone. The purpose of this study is to investigate the quality of mandibular bone at the sites of loosened screws. Therefore, we retrospectively studied bone quality at the fixation sites using multidetector row computed tomography images. We studied a total of 46 fixation screw sites in 6 patients—1 woman and 5 men with a mean age of 70 years (range, 54–78 years)—with cancer. They had been treated with titanium reconstruction plates (Walter Lorenz, Jacksonville, Fla., 2.4 mm locking reconstructive plates) wrapped with rectus abdominis myocutaneous free flaps. They all had undergone multidetector row computed tomography imaging (Aquilion One, 16 and 32; Toshiba). There were a mean of 3.8 (range, 3–6) fixation screws at each location. The mean follow-up was 22.6 months (range, 6–42). Bone quality was assessed by measuring the thickness of the mandible, the thickness of the outer and inner tables of the cortical bone, and the cancellous bone density measured in average computed tomography values (Hounsfield units) in a region of interest that had been shown by pretreatment multidetector row computed tomography to be closely related to hydroxyapatite concentration[4] (Fig. 1). The computed tomography values were accommodated between each unit. All analyses were performed using a software (INTAGE Realia).
Fig. 1.

Preoperative computed tomography of fixation screw sites. A, Sites of 4 fixation screws; B, Thickness of the mandible (a), inner table (b), and outer table (c) of cortical bone; C, Hounsfield units measured in a region of interest.

Preoperative computed tomography of fixation screw sites. A, Sites of 4 fixation screws; B, Thickness of the mandible (a), inner table (b), and outer table (c) of cortical bone; C, Hounsfield units measured in a region of interest. A total of 9 screws were loosened at both sides of the plate. Comparative studies were performed on these patients’ mandibular bones at sites where loosening did and did not occur. There were significant differences in the thickness of the lateral table of the cortical bone (P < 0.05) and in cancellous bone density (P < 0.05) at various sites (Table 1). However, no significant differences were recognized in the full thickness and inner table thickness of the mandible.
Table 1.

Results of Comparative Studies of Bone Quality

Results of Comparative Studies of Bone Quality These results indicate that cancellous bone density affects the stability of the fixation screws and also suggest that the thickness of the outer table of the mandibular bone affects plate stability. In patients with a mandibular reconstruction plate, biting force applied to the mandibular bone is transmitted to the contralateral mandible via the metal plate. When mechanical energy is considered, the inner table of the mandibular bone becomes a pivot point for the force, and the outer table is the point of loading (Fig. 2). The thickness of the outer table can influence the intensity at the point of loading. Our study suggests that patients with a thin outer table require supplemental fixation.
Fig. 2.

Application of force on the mandible via a plate. The inner table of the mandibular bone is the pivot point of the force. The mandibular bone outer table is the point of the load.

Application of force on the mandible via a plate. The inner table of the mandibular bone is the pivot point of the force. The mandibular bone outer table is the point of the load.

DISCLOSURE

The authors have no financial interest to declare in relation to the content of this article. The article processing charge was paid for by the authors.
  4 in total

1.  Increased plate and osteosynthesis related complications associated with postoperative concurrent chemoradiotherapy in oral cancer.

Authors:  Rajeev Sharan; Subramania Iyer; Shilpa S Chatni; Jacob Samuel; Karimassery R Sundaram; Richard F Cohen; Keechilat Pavithran; Moni Abraham Kuriakose
Journal:  Head Neck       Date:  2008-11       Impact factor: 3.147

2.  Quantitative computed tomography in measurement of vertebral trabecular bone mass. A modified method.

Authors:  M Nilsson; O Johnell; K Jonsson; I Redlund-Johnell
Journal:  Acta Radiol       Date:  1988 Nov-Dec       Impact factor: 1.990

3.  The free flap and plate in oromandibular reconstruction: long-term review and indications.

Authors:  J B Boyd; R S Mulholland; J Davidson; P J Gullane; L E Rotstein; D H Brown; J E Freeman; J C Irish
Journal:  Plast Reconstr Surg       Date:  1995-05       Impact factor: 4.730

4.  Complications after reconstruction by plate and soft-tissue free flap in composite mandibular defects and secondary salvage reconstruction with osteocutaneous flap.

Authors:  Fu-Chan Wei; Naci Celik; Wen-Guei Yang; I-How Chen; Yang-Ming Chang; Hung-Chi Chen
Journal:  Plast Reconstr Surg       Date:  2003-07       Impact factor: 4.730

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.