Literature DB >> 27256413

Reduction of radiation exposure in cryoballoon ablation procedures: a single-centre study applying intracardiac echocardiography and other radioprotective measures.

Vanessa Rubesch-Kütemeyer1, Stephan Molatta1, Jürgen Vogt2, Klaus-Jürgen Gutleben1, Dieter Horstkotte1, Georg Nölker1.   

Abstract

AIMS: The population treated with cryoballoon (CB) ablation is relatively young, and radiation protection is of major importance. We aimed to demonstrate that radiation exposure can be markedly reduced by intracardiac echocardiography (ICE) and optimized settings of the X-ray system. METHODS AND
RESULTS: We analysed 100 patients undergoing CB pulmonary vein isolation (PVI) for treatment of paroxysmal atrial fibrillation. In 50 consecutive patients (25 male, 59 ± 13 years; Group 1), we used ICE, skipped PV angiography prior to CB inflation, and avoided fluoroscopy whenever possible. Furthermore, we reduced the frame rate, minimized distance between patient and detector, and consequently applied collimation. These patients were compared with 50 similar preceding patients in Group 2 (29 male, 61 ± 12 years). Total fluoroscopy time was reduced from 18 ± 6 min in Group 2 to 12 ± 5 min in Group 1 (P < 0.001). Moreover, the dose area product was significantly lower (1555 ± 1219 vs. 4935 ± 2094 cGycm2, P < 0.001), total freezing time was significantly shortened (1855 ± 399 vs. 2121 ± 756 s, P = 0.031), and contrast media use was significantly reduced (66 ± 25 vs. 109 ± 27 mL, P < 0.001). At the same time, total procedure duration and complication rates did not differ significantly between both groups. After a 12 months follow-up, a similar percentage of patients was free from recurrences (74% in Group 1 vs. 78% in Group 2, P = 0.640).
CONCLUSION: Radiation exposure in CB PVI can be markedly reduced without prolonging procedure times, affecting the outcome or complication rates. Moreover, ICE seems to shorten total freezing time. Published on behalf of the European Society of Cardiology. All rights reserved.
© The Author 2016. For permissions please email: journals.permissions@oup.com.

Entities:  

Keywords:  Atrial fibrillation; Cryoablation; Intracardiac echocardiography; Pulmonary vein isolation; Radiation protection

Mesh:

Year:  2017        PMID: 27256413     DOI: 10.1093/europace/euw139

Source DB:  PubMed          Journal:  Europace        ISSN: 1099-5129            Impact factor:   5.214


  8 in total

1.  Visualization of isolated partially unroofed coronary sinus by intracardiac echocardiography.

Authors:  Naoko Sawada; Nobuhiko Ito; Osamu Harada
Journal:  J Echocardiogr       Date:  2017-03-01

2.  Cryoballoon ablation for atrial fibrillation without the use of a contrast medium: a combination of the intracardiac echocardiography and pressure wave monitoring guided approach.

Authors:  Yuichiro Makino; Yoshiaki Mizutani; Daiki Yamashita; Jun Yonekawa; Akinori Satake; Masanari Kurobe; Takatsugu Hiramatsu; Hitoshi Ichimiya; Yasuhiro Uchida; Junji Watanabe; Masaaki Kanashiro; Satoshi Ichimiya; Satoshi Yanagisawa; Yasuya Inden; Toyoaki Murohara
Journal:  Heart Vessels       Date:  2021-10-12       Impact factor: 2.037

Review 3.  [Update on radiation exposure in catheter ablation of atrial fibrillation].

Authors:  Tobias Schreiber; Nora Kähler; Verena Tscholl; Patrick Nagel; Ulf Landmesser; Martin Huemer; Philipp Attanasio
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2019-11-22

4.  JCS/JHRS 2021 guideline focused update on non-pharmacotherapy of cardiac arrhythmias.

Authors:  Akihiko Nogami; Takashi Kurita; Kengo Kusano; Masahiko Goya; Morio Shoda; Hiroshi Tada; Shigeto Naito; Teiichi Yamane; Masaomi Kimura; Tsuyoshi Shiga; Kyoko Soejima; Takashi Noda; Hiro Yamasaki; Yoshifusa Aizawa; Tohru Ohe; Takeshi Kimura; Shun Kohsaka; Hideo Mitamura
Journal:  J Arrhythm       Date:  2022-01-07

Review 5.  Strategies to Improve the Outcome of Cryoballoon Ablation in the Treatment of Atrial Fibrillation.

Authors:  Ying Huang; Yuehan Wang; Chenyu Song
Journal:  Biomed Res Int       Date:  2020-04-06       Impact factor: 3.411

6.  The use of intracardiac echocardiography catheters in endocardial ablation of cardiac arrhythmia: Meta-analysis of efficiency, effectiveness, and safety outcomes.

Authors:  Masahiko Goya; Diana Frame; Larry Gache; Yoko Ichishima; Daiane Oliveira Tayar; Laura Goldstein; Stephanie Hsiao Yu Lee
Journal:  J Cardiovasc Electrophysiol       Date:  2020-01-30

7.  Reducing radiation exposure in second-generation cryoballoon ablation without compromising clinical outcome.

Authors:  Marijn J Holl; Rohit E Bhagwandien; Mehran Firouzi; Wouter A de Ruiter; Tamas Szili-Torok; Sing-Chien Yap
Journal:  J Interv Card Electrophysiol       Date:  2020-04-13       Impact factor: 1.900

8.  Ablation for paroxysmal atrial fibrillation-real-life results from a middle-volume electrophysiology laboratory.

Authors:  Piotr Kulakowski; Agnieszka Sikorska; Roman Piotrowski; Tomasz Kryński; Jakub Baran
Journal:  J Interv Card Electrophysiol       Date:  2021-01-09       Impact factor: 1.900

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.