Literature DB >> 27255256

Assessing the in vitro optical quality of presbyopic solutions based on the axial modulation transfer function.

Eleni Papadatou1, Antonio J Del Águila-Carrasco2, José J Esteve-Taboada2, David Madrid-Costa2, Robert Montés-Micó2.   

Abstract

PURPOSE: To present a metric for assessing the in vitro optical quality of rotationally symmetrical optical elements based on volume calculation under the surface defined by the axial modulation transfer function (MTF).
SETTING: University of Valencia, Valencia, Spain.
DESIGN: Experimental study.
METHODS: The metric volume under the axial MTF was used to assess the optical quality of 2 rotationally symmetrical multifocal intraocular lenses (IOLs) within various defocus intervals (0.50 diopter [D], 0.75 D, and 1.00 D) and at various spatial frequency intervals (7.5 cycles per degree [cpd], 15.0 cpd, and 30.0 cpd).
RESULTS: The far focus of the bifocal IOL yielded higher volume values at all spatial frequencies and defocus intervals than the trifocal IOL. The results for the near focus were similar for both IOLs. In addition, the trifocal IOL provided a distinct focus for intermediate vision.
CONCLUSIONS: The volume under the axial MTF proved to be a useful tool for objective evaluation of multifocal IOLs. Moreover, it can be applied to evaluate the optical quality of every rotationally symmetrical IOL or optical element. FINANCIAL DISCLOSURE: None of the authors has a financial or proprietary interest in any material or method mentioned.
Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Mesh:

Year:  2016        PMID: 27255256     DOI: 10.1016/j.jcrs.2015.11.049

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  5 in total

1.  Temporal multiplexing with adaptive optics for simultaneous vision.

Authors:  Eleni Papadatou; Antonio J Del Águila-Carrasco; Iván Marín-Franch; Norberto López-Gil
Journal:  Biomed Opt Express       Date:  2016-09-15       Impact factor: 3.732

2.  Repeatability of in-vitro optical quality measurements of intraocular lenses with a deflectometry technique effect of the toricity.

Authors:  Teresa Ferrer-Blasco; Alberto Domínguez-Vicent; Santiago García-Lázaro; María Amparo Díez-Ajenjo; José F Alfonso; José J Esteve-Taboada
Journal:  Int J Ophthalmol       Date:  2018-07-18       Impact factor: 1.779

3.  Early outcomes of vision and objective visual quality analysis after cataract surgery with trifocal intraocular lens implantation.

Authors:  Mei-Fang Chu; Na Hui; Cong-Yi Wang; Lei Yu; Bo Ma; Yan Li; Cheng Pei
Journal:  Int J Ophthalmol       Date:  2019-10-18       Impact factor: 1.779

4.  Patient selection to optimize near vision performance with a low-addition trifocal lens.

Authors:  Joaquín Fernández; Manuel Rodríguez-Vallejo; Javier Martínez; Ana Tauste; David P Piñero
Journal:  J Optom       Date:  2019-11-01

5.  Trifocal versus Bifocal Diffractive Intraocular Lens Implantation after Cataract Surgery or Refractive Lens Exchange: a Meta-analysis.

Authors:  Chang Ho Yoon; In-Soo Shin; Mee Kum Kim
Journal:  J Korean Med Sci       Date:  2018-09-27       Impact factor: 2.153

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.