Literature DB >> 27255246

Relationship of corneal asphericity to intraocular lens power calculations after myopic laser in situ keratomileusis.

Yosai Mori1, Kimiya Shimizu1, Keiichiro Minami1, Kazutaka Kamiya1, Nobuyuki Shoji1, Kazunori Miyata2.   

Abstract

PURPOSE: To examine whether corneal asphericity affects underestimation in the SRK/T intraocular lens (IOL) power calculation after myopic laser in situ keratomileusis (LASIK) and to evaluate the predictability of IOL power underestimation using the asphericity.
SETTING: Kitasato University, Kanagawa, and Miyata Eye Hospital, Miyazaki, Japan.
DESIGN: Retrospective case series.
METHODS: The clinical records of eyes that had IOL implantation during cataract surgery after previous myopic LASIK between May 2008 and October 2014 were reviewed. For eyes with an available clinical history, the effect of manifest refraction spherical equivalent before LASIK, axial length, and the asphericity (Q value) on cataract surgery and the refractive error in the use of the SRK/T formula were examined using stepwise multiple regression analysis. Predictions with the resultant regression equation and significant factors were evaluated with Bland-Altman plots.
RESULTS: Fifty-four eyes of 37 patients were included. The mean duration from LASIK to cataract surgery was 9.1 years ± 3.5 (SD) (range 2 to 14 years). Multiple regression analysis using 22 eyes of 22 patients resulted in a significant factor, which was the Q value (P < .001, R(2) = 0.80). The refractive errors in 53 eyes were predicted with tolerances of 64.5% and 87.0% within ±0.5 diopter (D) and within ±1.0 D, respectively. Bland-Altman analysis showed that 95% of the limitation range was 2.59 D.
CONCLUSIONS: The corneal asphericity after myopic LASIK significantly correlated with the IOL power underestimation with use of the SRK/T formula. The refractive error could also be predicted well with the use of asphericity. FINANCIAL DISCLOSURE: None of the authors has a financial or proprietary interest in any material or method mentioned.
Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2016        PMID: 27255246     DOI: 10.1016/j.jcrs.2016.01.050

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  2 in total

1.  The influence of corneal ablation patterns on prediction error after cataract surgery in post-myopic-LASIK eyes.

Authors:  Yunqian Yao; Jing Zhao; Jifeng Yu; Wenwen He; Ling Wei; Xingtao Zhou; Yi Lu; Xiangjia Zhu
Journal:  Eye Vis (Lond)       Date:  2022-07-01

2.  Effect of the ratio of axial length to keratometry on SRK/T intraocular lens power calculations for eyes with long axial lengths.

Authors:  Yosai Mori; Keiichiro Minami; Shota Tokuda; Jinhee Lee; Kazunori Miyata
Journal:  Sci Rep       Date:  2019-12-20       Impact factor: 4.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.