N Mohd-Taufek1, D Cartwright2,3, M Davies2,3, A K Hewavitharana1, P Koorts2,3, H McConachy2, P N Shaw1, R Sumner4, K Whitfield1,2. 1. School of Pharmacy, The University of Queensland, Brisbane, QLD, Australia. 2. Grantley Stable Neonatal Unit, Royal Brisbane and Women's Hospital, Metro North Health Services District, Herston, QLD, Australia. 3. Department of Paediatrics & Child Health, The University of Queensland, Brisbane, QLD, Australia. 4. Inorganic Chemistry Laboratory, Queensland Health Forensic and Scientific Services, Coopers Plains, Brisbane, QLD, Australia.
Abstract
OBJECTIVE: Premature infants often receive pasteurized donor human milk when mothers are unable to provide their own milk. This study aims to establish the effect of the pasteurization process on a range of trace elements in donor milk. STUDY DESIGN: Breast milk was collected from 16 mothers donating to the milk bank at the Royal Brisbane and Women's Hospital. Samples were divided into pre- and post-pasteurization aliquots and were Holder pasteurized. Inductively coupled plasma mass spectrometry was used to analyze the trace elements zinc (Zn), copper (Cu), selenium (Se), manganese (Mn), iodine (I), iron (Fe), molybdenum (Mo) and bromine (Br). Differences in trace elements pre- and post-pasteurization were analyzed. RESULTS: No significant differences were found between the trace elements tested pre- and post-pasteurization, except for Fe (P<0.05). The median (interquartile range, 25 to 75%; μg l(-1)) of trace elements for pre- and post- pasteurization aliquots were-Zn: 1639 (888-4508), 1743 (878-4143), Cu: 360 (258-571), 367 (253-531), Se: 12.34 (11.73-17.60), 12.62 (11.94-16.64), Mn: (1.48 (1.01-1.75), 1.49 (1.11-1.75), I (153 (94-189), 158 (93-183), Fe (211 (171-277), 194 (153-253), Mo (1.46 (0.37-2.99), 1.42 (0.29-3.73) and Br (1066 (834-1443), 989 (902-1396). CONCLUSIONS: Pasteurization had minimal effect on several trace elements in donor breast milk but high levels of inter-donor variability of trace elements were observed. The observed decrease in the iron content of pasteurized donor milk is, however, unlikely to be clinically relevant.
OBJECTIVE: Premature infants often receive pasteurized donorhuman milk when mothers are unable to provide their own milk. This study aims to establish the effect of the pasteurization process on a range of trace elements in donor milk. STUDY DESIGN: Breast milk was collected from 16 mothers donating to the milk bank at the Royal Brisbane and Women's Hospital. Samples were divided into pre- and post-pasteurization aliquots and were Holder pasteurized. Inductively coupled plasma mass spectrometry was used to analyze the trace elements zinc (Zn), copper (Cu), selenium (Se), manganese (Mn), iodine (I), iron (Fe), molybdenum (Mo) and bromine (Br). Differences in trace elements pre- and post-pasteurization were analyzed. RESULTS: No significant differences were found between the trace elements tested pre- and post-pasteurization, except for Fe (P<0.05). The median (interquartile range, 25 to 75%; μg l(-1)) of trace elements for pre- and post- pasteurization aliquots were-Zn: 1639 (888-4508), 1743 (878-4143), Cu: 360 (258-571), 367 (253-531), Se: 12.34 (11.73-17.60), 12.62 (11.94-16.64), Mn: (1.48 (1.01-1.75), 1.49 (1.11-1.75), I (153 (94-189), 158 (93-183), Fe (211 (171-277), 194 (153-253), Mo (1.46 (0.37-2.99), 1.42 (0.29-3.73) and Br (1066 (834-1443), 989 (902-1396). CONCLUSIONS: Pasteurization had minimal effect on several trace elements in donor breast milk but high levels of inter-donor variability of trace elements were observed. The observed decrease in the iron content of pasteurized donor milk is, however, unlikely to be clinically relevant.
Authors: C Dani; E Martelli; G Bertini; M Pezzati; M Rossetti; G Buonocore; P Paffetti; F F Rubaltelli Journal: Arch Dis Child Fetal Neonatal Ed Date: 2004-09 Impact factor: 5.747
Authors: Mariana M Oliveira; Davi C Aragon; Vanessa S Bomfim; Tânia M B Trevilato; Larissa G Alves; Anália R Heck; Francisco E Martinez; José S Camelo Journal: PLoS One Date: 2019-02-20 Impact factor: 3.240
Authors: Min Hyung Kim; Kyu Seok Shim; Dae Yong Yi; In Seok Lim; Soo Ahn Chae; Sin Weon Yun; Na Mi Lee; Su Yeong Kim; Seung Kim Journal: Pediatr Gastroenterol Hepatol Nutr Date: 2019-04-23