Feasibility of ultra low-dose thallium stress-redistribution protocol including prone imaging in obese patients using CZT camera.

Vladimír Kincl1,2, Milan Kamínek3,4, Jiří Vašina3,5, Roman Panovský3,6, Martin Havel4.   

Abstract

High efficiency cadmium-zinc-telluride (CZT) cameras provide an opportunity to lower the injected activities of radiopharmaceuticals for single photon emission tomography (SPECT) myocardial perfusion imaging (MPI). The limits for reducing activities of thallium have not been determined, particularly in obese patients. After an injection of 0.7 megabecquerel (MBq) of thallium/kg, we collected an average 1.5 million counts for the 10-min acquisition in a pilot cohort of ten patients. After extrapolation, we reduced the administered activity to 0.5 MBq/kg to obtain the expected 1 million counts. We studied the image quality in 124 patients (86 men, 43 obese with body mass index over 30 kg/m2) referred for MPI. The quality of images was assessed by a number of recorded counts and visually by a four-grade scale (one-poor quality, four-excellent quality). In non-obese and obese patients, the average number of recorded counts was 1.1 vs. 1.07 million counts for the 10-min stress acquisition, 1.04 vs. 1.06 million counts for the 13-min rest acquisition, and the average quality score was 3.97 vs. 3.90, respectively (p = NS).The mean administered activity was 39.2 ± 7 MBq for non-obese and 48.7 ± 6 for obese patients (p < 0.0001), and the calculated effective dose was 4.0 ± 0.7 and 4.9 ± 0.6 mSv respectively (p < 0.0001). The ultra-low-dose thallium stress-redistribution protocol, including post-stress prone imaging, provides good quality of images with a low radiation burden, even in obese patients.

Entities:  

Keywords:  Cadmium–zinc–telluride; Myocardial perfusion imaging; Obese patients; Prone imaging; Thallium; Ultra low-dose

Mesh:

Substances:

Year:  2016        PMID: 27250348     DOI: 10.1007/s10554-016-0919-8

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  20 in total

Review 1.  Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart. A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association.

Authors:  Manuel D Cerqueira; Neil J Weissman; Vasken Dilsizian; Alice K Jacobs; Sanjiv Kaul; Warren K Laskey; Dudley J Pennell; John A Rumberger; Thomas Ryan; Mario S Verani
Journal:  Circulation       Date:  2002-01-29       Impact factor: 29.690

2.  Low-dose thallium-201 protocol with a cadmium-zinc-telluride cardiac camera.

Authors:  Bernard Songy; Mohamed Guernou; David Lussato; Mathieu Queneau; Ricardo Geronazzo
Journal:  Nucl Med Commun       Date:  2012-05       Impact factor: 1.690

3.  Early image acquisition using a solid-state cardiac camera for fast myocardial perfusion imaging.

Authors:  J Wells Askew; Todd D Miller; Royce L Ruter; Lennon G Jordan; David O Hodge; Raymond J Gibbons; Michael K O'Connor
Journal:  J Nucl Cardiol       Date:  2011-07-12       Impact factor: 5.952

4.  Quantitative high-efficiency cadmium-zinc-telluride SPECT with dedicated parallel-hole collimation system in obese patients: results of a multi-center study.

Authors:  Ryo Nakazato; Piotr J Slomka; Mathews Fish; Ronald G Schwartz; Sean W Hayes; Louise E J Thomson; John D Friedman; Mark Lemley; Maria L Mackin; Benjamin Peterson; Arielle M Schwartz; Jesse A Doran; Guido Germano; Daniel S Berman
Journal:  J Nucl Cardiol       Date:  2014-11-12       Impact factor: 5.952

5.  Comparison of the diagnostic accuracies of very low stress-dose with standard-dose myocardial perfusion imaging: Automated quantification of one-day, stress-first SPECT using a CZT camera.

Authors:  Tali Sharir; Marina Pinskiy; Abraham Pardes; Arik Rochman; Vitali Prokhorov; Gil Kovalski; Konstantine Merzon; Andrzej Bojko; Boris Brodkin
Journal:  J Nucl Cardiol       Date:  2015-05-27       Impact factor: 5.952

6.  Diagnostic performance of a novel cadmium-zinc-telluride gamma camera system assessed using fractional flow reserve.

Authors:  Hirokazu Tanaka; Taishiro Chikamori; Nobuhiro Tanaka; Satoshi Hida; Yuko Igarashi; Jun Yamashita; Masashi Ogawa; Chie Shiba; Yasuhiro Usui; Akira Yamashina
Journal:  Circ J       Date:  2014-09-22       Impact factor: 2.993

7.  Comparison of the myocardial uptake of a technetium-labeled isonitrile analogue and thallium.

Authors:  J A Leppo; D J Meerdink
Journal:  Circ Res       Date:  1989-09       Impact factor: 17.367

8.  Compared performance of high-sensitivity cameras dedicated to myocardial perfusion SPECT: a comprehensive analysis of phantom and human images.

Authors:  Laetitia Imbert; Sylvain Poussier; Philippe R Franken; Bernard Songy; Antoine Verger; Olivier Morel; Didier Wolf; Alain Noel; Gilles Karcher; Pierre-Yves Marie
Journal:  J Nucl Med       Date:  2012-11-08       Impact factor: 10.057

9.  Novel solid-state-detector dedicated cardiac camera for fast myocardial perfusion imaging: multicenter comparison with standard dual detector cameras.

Authors:  Fabio P Esteves; Paolo Raggi; Russell D Folks; Zohar Keidar; J Wells Askew; Shmuel Rispler; Michael K O'Connor; Liudmilla Verdes; Ernest V Garcia
Journal:  J Nucl Cardiol       Date:  2009-08-18       Impact factor: 5.952

10.  Effective dose to adult patients from 338 radiopharmaceuticals estimated using ICRP biokinetic data, ICRP/ICRU computational reference phantoms and ICRP 2007 tissue weighting factors.

Authors:  Martin Andersson; Lennart Johansson; David Minarik; Sigrid Leide-Svegborn; Sören Mattsson
Journal:  EJNMMI Phys       Date:  2014-09-29
View more
  2 in total

1.  Tl-201 dosing for CZT SPECT: More new information.

Authors:  M J Henzlova; W L Duvall
Journal:  J Nucl Cardiol       Date:  2017-02-07       Impact factor: 5.952

2.  Cardiovascular imaging 2016 in the International Journal of Cardiovascular Imaging.

Authors:  Johan H C Reiber; Johan De Sutter; Paul Schoenhagen; Arthur E Stillman; Nico R L Vande Veire
Journal:  Int J Cardiovasc Imaging       Date:  2017-06       Impact factor: 2.357

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.