Literature DB >> 27247058

Quantification of vaginal motion associated with daily endorectal balloon placement during whole pelvis radiotherapy for gynecologic cancers.

Nicolette Taku1, Joseph Dise1, Owen Kenton1, Lingshu Yin1, Boon-Keng Kevin Teo1, Lilie L Lin2.   

Abstract

BACKGROUND AND
PURPOSE: To quantify intra-treatment vaginal motion in women treated with daily endorectal balloon (ERB) placement and external beam radiotherapy for gynecologic cancers.
MATERIALS AND METHODS: Eighteen post-hysterectomy women with gynecologic cancers underwent computed tomography (CT) simulation scans and daily treatment with ERB. Fiducial markers were placed at the vaginal apex prior to simulation and patients were counseled on a pre-treatment bladder filling protocol. Weekly to biweekly verification CT scans were used to calculate the intra-treatment change in bladder volumes, rectal volumes, and fiducial coordinates along all axes. The planning target volume (PTV) margins required to encompass 95% of intra-treatment fiducial movement were calculated using the van Herk margin recipe.
RESULTS: The median bladder volume was 223 (range, 29-879)cc for verification CT scans. Mean intra-treatment fiducial displacements were 1.7 (range, 0-9.1)mm, 2.9 (range, 0-15.5)mm, and 2.5 (range, 0-11.8)mm along the left-right (L/R), superior-inferior (S/I), and anterior-posterior (A/P) axes, respectively. The van Herk PTV margins were 3mm (L/R), 10mm (S/I) and 7mm (A/P).
CONCLUSION: When compared to existing studies, the use of daily ERB with post-hysterectomy radiotherapy reduces vaginal motion along the A/P axis. The impact of variable bladder filling on vaginal motion is most evident along the S/I axis.
Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Keywords:  Bladder filling; Endorectal balloon; External beam radiation; Gynecologic cancer; Vaginal movement

Mesh:

Year:  2016        PMID: 27247058     DOI: 10.1016/j.radonc.2016.05.005

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  2 in total

1.  Does ITV vaginal procedure ensure dosimetric coverage during IMRT of post-operative gynaecological tumours without instructions concerning rectal filling?

Authors:  Ramona Verges; Alexandra Giraldo; Alejandro Seoane; Elisabet Toral; M Carmen Ruiz; Ariadna Pons; Jordi Giralt
Journal:  Rep Pract Oncol Radiother       Date:  2018-03-02

2.  Geometric and dosimetric evaluation of the differences between rigid and deformable registration to assess interfraction motion during pelvic radiotherapy.

Authors:  Ingrid White; Dualta McQuaid; Helen McNair; Alex Dunlop; Steven Court; Naomi Hopkins; Karen Thomas; David Dearnaley; Shree Bhide; Susan Lalondrelle
Journal:  Phys Imaging Radiat Oncol       Date:  2019-04-05
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.