Literature DB >> 27243917

Intraday and Interday Reliability of Ultra-Short-Term Heart Rate Variability in Rugby Union Players.

Fábio Y Nakamura1, Lucas A Pereira, Michael R Esco, Andrew A Flatt, José E Moraes, Cesar C Cal Abad, Irineu Loturco.   

Abstract

Nakamura, FY, Pereira, LA, Esco, MR, Flatt, AA, Moraes, JE, Cal Abad, CC, and Loturco, I. Intraday and interday reliability of ultra-short-term heart rate variability in rugby union players. J Strength Cond Res 31(2): 548-551, 2017-The aim of this study was to examine the intraday and interday reliability of ultra-short-term vagal-related heart rate variability (HRV) in elite rugby union players. Forty players from the Brazilian National Rugby Team volunteered to participate in this study. The natural log of the root mean square of successive RR interval differences (lnRMSSD) assessments were performed on 4 different days. The HRV was assessed twice (intraday reliability) on the first day and once per day on the following 3 days (interday reliability). The RR interval recordings were obtained from 2-minute recordings using a portable heart rate monitor. The relative reliability of intraday and interday lnRMSSD measures was analyzed using the intraclass correlation coefficient (ICC). The typical error of measurement (absolute reliability) of intraday and interday lnRMSSD assessments was analyzed using the coefficient of variation (CV). Both intraday (ICC = 0.96; CV = 3.99%) and interday (ICC = 0.90; CV = 7.65%) measures were highly reliable. The ultra-short-term lnRMSSD is a consistent measure for evaluating elite rugby union players, in both intraday and interday settings. This study provides further validity to using this shortened method in practical field conditions with highly trained team sports athletes.

Mesh:

Year:  2017        PMID: 27243917     DOI: 10.1519/JSC.0000000000001514

Source DB:  PubMed          Journal:  J Strength Cond Res        ISSN: 1064-8011            Impact factor:   3.775


  10 in total

1.  The Accuracy of Acquiring Heart Rate Variability from Portable Devices: A Systematic Review and Meta-Analysis.

Authors:  Ward C Dobbs; Michael V Fedewa; Hayley V MacDonald; Clifton J Holmes; Zackary S Cicone; Daniel J Plews; Michael R Esco
Journal:  Sports Med       Date:  2019-03       Impact factor: 11.136

2.  Intra-Individual Variation of HRV during Orthostatic Challenge in Elite Male Field Hockey Players.

Authors:  Jason D Vescovi
Journal:  J Med Syst       Date:  2019-10-27       Impact factor: 4.460

3.  Minimal Window Duration for Accurate HRV Recording in Athletes.

Authors:  Nicolas Bourdillon; Laurent Schmitt; Sasan Yazdani; Jean-Marc Vesin; Grégoire P Millet
Journal:  Front Neurosci       Date:  2017-08-10       Impact factor: 4.677

4.  Match Fatigue Time-Course Assessment Over Four Days: Usefulness of the Hooper Index and Heart Rate Variability in Professional Soccer Players.

Authors:  Alireza Rabbani; Filipe Manuel Clemente; Mehdi Kargarfard; Karim Chamari
Journal:  Front Physiol       Date:  2019-02-19       Impact factor: 4.566

5.  Impact of heart rate on reproducibility of heart rate variability analysis in the supine and standing positions in healthy men.

Authors:  Carlos Janssen Gomes da Cruz; Luiz Guilherme Grossi Porto; Paloma da Silva Rolim; Deleon de Souza Pires; Giliard Lago Garcia; Guilherme Eckhardt Molina
Journal:  Clinics (Sao Paulo)       Date:  2019-08-12       Impact factor: 2.365

6.  Incorporating Internal and External Training Load Measurements in Clinical Decision Making After ACL Reconstruction: A Clinical Commentary.

Authors:  Jeffrey B Taylor; Kevin R Ford; Robin M Queen; Elizabeth C Owen; Angela Spontelli Gisselman
Journal:  Int J Sports Phys Ther       Date:  2021-04-02

7.  Inter- and Intra-Day Comparisons of Smartphone-Derived Heart Rate Variability across Resistance Training Overload and Taper Microcycles.

Authors:  Tyler D Williams; Michael R Esco; Michael V Fedewa; Phillip A Bishop
Journal:  Int J Environ Res Public Health       Date:  2020-12-29       Impact factor: 3.390

8.  On-Court Change of Direction Test: an Effective Approach To Assess COD Performance in Badminton Players.

Authors:  Jaime Fernandez-Fernandez; Irineu Loturco; Jose Luis Hernández-Davó; Fabio Y Nakamura; Vicente García-Tormo; Francisco Álvarez-Dacal; Jonathan Martinez-Maseda; Juan García-López
Journal:  J Hum Kinet       Date:  2022-04-26       Impact factor: 2.923

9.  Heart-Rate Variability Recording Time and Performance in Collegiate Female Rowers.

Authors:  Sara R Sherman; Clifton J Holmes; Bjoern Hornikel; Hayley V MacDonald; Michael V Fedewa; Michael R Esco
Journal:  Int J Sports Physiol Perform       Date:  2021-02-09       Impact factor: 4.010

10.  Validity of Smartphone Heart Rate Variability Pre- and Post-Resistance Exercise.

Authors:  Clifton J Holmes; Michael V Fedewa; Lee J Winchester; Hayley V MacDonald; Stefanie A Wind; Michael R Esco
Journal:  Sensors (Basel)       Date:  2020-10-09       Impact factor: 3.576

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.