Literature DB >> 2724380

Intrinsic problems with the external fixation device of Hoffmann-Vidal-Adrey: a critical evaluation of 117 patients with complex tibial shaft fractures.

P Rommens1, J Gielen, P Broos, J Gruwez.   

Abstract

In the 1978-1986 period, 117 patients with 119 fresh and complex fractures of the lower leg were secured primarily with a Hoffmann-Vidal-Adrey external fixation device. Ninety-five fractures could be followed until bony consolidation. In 12 fractures (12.7%) a pseudarthrosis developed, and a deep infection in four (4.2%). The external fixation device was attached for an average time of 25.0 weeks. Pin loosening was seen in seven patients (7.3%), minor pin-tract infection in nine (9.4%), and major pin-tract infection in three patients (3.1%). Fourteen fractures needed a secondary internal fixation; in 17 other fractures a secondary transplantation of cancellous bone autografts without internal fixation was carried out. After healing of the soft tissues, the tibial fracture can be regarded as a closed one and other therapeutic procedures to accelerate bony consolidation should be taken into account. The advantages and disadvantages of a second internal stabilization should be evaluated for every fracture with bone healing problems. The alteration from external to internal fixation makes an early removal of the external fixator possible and prevents in this way the intrinsic problems combined with this fixation type such as delayed union, nonunion, pin loosening, or pin-tract infection.

Entities:  

Mesh:

Year:  1989        PMID: 2724380     DOI: 10.1097/00005373-198905000-00018

Source DB:  PubMed          Journal:  J Trauma        ISSN: 0022-5282


  4 in total

1.  Antibacterial effect of 317L stainless steel contained copper in prevention of implant-related infection in vitro and in vivo.

Authors:  Hongwei Chai; Lei Guo; Xiantao Wang; Yuping Fu; Junlin Guan; Lili Tan; Ling Ren; Ke Yang
Journal:  J Mater Sci Mater Med       Date:  2011-08-26       Impact factor: 3.896

2.  Staged external and internal locked plating for open distal tibial fractures.

Authors:  Ching-Hou Ma; Shang-Won Yu; Yuan-Kun Tu; Cheng-Yo Yen; James Jih-Hsi Yeh; Chin-Hsien Wu
Journal:  Acta Orthop       Date:  2010-06       Impact factor: 3.717

3.  Unreamed intramedullary nailing in distal tibial fractures.

Authors:  Khaled Hamed Salem
Journal:  Int Orthop       Date:  2013-07-28       Impact factor: 3.075

4.  Seasonal Temperature and Pin Site Care Regimen Affect the Incidence of Pin Site Infection in Pediatric Supracondylar Humeral Fractures.

Authors:  Hsuan-Kai Kao; Mei-Chuan Chen; Wei-Chun Lee; Wen-E Yang; Chia-Hsieh Chang
Journal:  Biomed Res Int       Date:  2015-04-29       Impact factor: 3.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.