Radiation dose and diagnostic image quality associated with iterative reconstruction in coronary CT angiography: A systematic review.

Kamarul Amin Abdullah1,2, Mark F McEntee1, Warren Reed1, Peter L Kench1.   

Abstract

The aim of this systematic review is to evaluate the radiation dose reduction achieved using iterative reconstruction (IR) compared to filtered back projection (FBP) in coronary CT angiography (CCTA) and assess the impact on diagnostic image quality. A systematic search of seven electronic databases was performed to identify all studies using a developed keywords strategy. A total of 14 studies met the criteria and were included in a review analysis. The results showed that there was a significant reduction in radiation dose when using IR compared to FBP (P < 0.05). The mean and standard deviation (SD) difference of CTDIvol and dose-length-product (DLP) were 14.70 ± 6.87 mGy and 186 ± 120 mGy.cm respectively. The mean ± SD difference of effective dose (ED ) was 2.9 ± 1.7 mSv with the range from 1.0 to 5.0 mSv. The assessment of diagnostic image quality showed no significant difference (P > 0.05). The mean ± SD difference of image noise, signal-noise ratio (SNR) and contrast-noise ratio (CNR) were 1.05 ± 1.29 HU, 0.88 ± 0.56 and 0.63 ± 1.83 respectively. The mean ± SD percentages of overall image quality scores were 71.79 ± 12.29% (FBP) and 67.31 ± 22.96% (IR). The mean ± SD percentages of coronary segment analysis were 95.43 ± 2.57% (FBP) and 97.19 ± 2.62% (IR). In conclusion, this review analysis shows that CCTA with the use of IR leads to a significant reduction in radiation dose as compared to the use of FBP. Diagnostic image quality of IR at reduced dose (30-41%) is comparable to FBP at standard dose in the diagnosis of CAD.
© 2016 The Royal Australian and New Zealand College of Radiologists.

Entities:  

Keywords:  coronary CT angiography; coronary artery disease; dose reduction; filtered back projection; iterative reconstruction

Mesh:

Year:  2016        PMID: 27241506     DOI: 10.1111/1754-9485.12473

Source DB:  PubMed          Journal:  J Med Imaging Radiat Oncol        ISSN: 1754-9477            Impact factor:   1.735


  8 in total

1.  Use of a channelized Hotelling observer to assess CT image quality and optimize dose reduction for iteratively reconstructed images.

Authors:  Christopher P Favazza; Andrea Ferrero; Lifeng Yu; Shuai Leng; Kyle L McMillan; Cynthia H McCollough
Journal:  J Med Imaging (Bellingham)       Date:  2017-10-03

2.  Development of an organ-specific insert phantom generated using a 3D printer for investigations of cardiac computed tomography protocols.

Authors:  Kamarul A Abdullah; Mark F McEntee; Warren Reed; Peter L Kench
Journal:  J Med Radiat Sci       Date:  2018-04-30

3.  Influence of Contrast Agent Injection Scheme Customized by Dual-Source CT Based on Automatic Tube Voltage Technology on Image Quality and Radiation Dose of Coronary Artery Imaging.

Authors:  Weiling He; Xin Chen; Rui Hu; Wenjie Sun; Weili Tan
Journal:  Front Surg       Date:  2022-04-05

4.  Tradeoff between noise reduction and inartificial visualization in a model-based iterative reconstruction algorithm on coronary computed tomography angiography.

Authors:  Kenichiro Hirata; Daisuke Utsunomiya; Masafumi Kidoh; Yoshinori Funama; Seitaro Oda; Hideaki Yuki; Yasunori Nagayama; Yuji Iyama; Takeshi Nakaura; Daisuke Sakabe; Kenichi Tsujita; Yasuyuki Yamashita
Journal:  Medicine (Baltimore)       Date:  2018-05       Impact factor: 1.889

5.  Automatic tube potential selection with tube current modulation in coronary CT angiography: Can it achieve consistent image quality among various individuals?

Authors:  Xiao-Ping Wang; Xiao-Mei Zhu; Yin-Su Zhu; Wang-Yan Liu; Xiao-Han Yang; Wei-Wei Huang; Yi Xu; Li-Jun Tang
Journal:  Exp Ther Med       Date:  2018-05-11       Impact factor: 2.447

6.  Evaluation of an integrated 3D-printed phantom for coronary CT angiography using iterative reconstruction algorithm.

Authors:  Kamarul A Abdullah; Mark F McEntee; Warren Reed; Peter L Kench
Journal:  J Med Radiat Sci       Date:  2020-03-27

7.  Increasing iterative reconstruction strength at low tube voltage in coronary CT angiography protocols using 3D-printed and Catphan® 500 phantoms.

Authors:  Kamarul A Abdullah; Mark F McEntee; Warren M Reed; Peter L Kench
Journal:  J Appl Clin Med Phys       Date:  2020-07-13       Impact factor: 2.102

8.  Coronary computed tomography angiography using model-based iterative reconstruction algorithms in the detection of significant coronary stenosis: how the plaque type influences the diagnostic performance.

Authors:  Antonio Vizzuso; Riccardo Righi; Aldo Carnevale; Michela Zerbini; Giorgio Benea; Melchiore Giganti
Journal:  Pol J Radiol       Date:  2019-12-09
  8 in total