Pt@AuNPs integrated quantitative capillary-based biosensors for point-of-care testing application.

Ze Wu1, Qiangqiang Fu1, Shiting Yu1, Liangrong Sheng2, Meng Xu2, Cuize Yao1, Wei Xiao1, Xiuqing Li1, Yong Tang3.   

Abstract

Current diagnostic technologies primarily rely on bulky and costly analytical instruments. Therefore, cost-effective and portable diagnosis tools that can be used for point-of-care tests (POCT) are highly desirable. In this study, we report a cost-effective, portable capillary-based biosensor for quantitative detection of biomarkers by the naked eye. This capillary-based biosensor was tested by measuring the distance of blue ink movement, which was directly correlated with the oxygen (O2) produced by efficient core-shell Pt@Au nanoparticles (Pt@AuNPs) catalysts decomposed hydrogen peroxide (H2O2). By linking the Pt@AuNPs with antibodies, capillary-based biosensor sandwich immunoassays were constructed. The concentrations of the target proteins were positively correlated with the distances of ink movement. To demonstrate their performance, the biosensors were used to detect the cancer biomarker sprostate-specific antigen (PSA) and carcinoembryonic antigen (CEA). The linear detection range (LDR) of the capillary-based biosensor for detecting PSA was from 0.02 to 2.5ng/mL, and the limit of detection (LOD) was 0.017ng/mL. LDR of the biosensor for detecting CEA was from 0.063 to 16ng/mL, and the LOD was 0.044ng/mL. For detection of PSA and CEA in clinical serum samples, the detection results of the capillary-based biosensor were well correlate with the results from of chemiluminescence immunoassays (CLIAs). Thus, the capillary-based biosensor may potentially be a useful strategy for point-of-care testing, in addition to being portable and cost effective.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Capillary-based biosensor; Carcinoembryonicantigen; Core-shell Pt@Au nanoparticle; Point-of-care testing; Prostate-specific antigen

Mesh:

Substances:

Year:  2016        PMID: 27240013     DOI: 10.1016/j.bios.2016.05.074

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  3 in total

1.  Lateral flow assay ruler for quantitative and rapid point-of-care testing.

Authors:  Zhao Li; Hui Chen; Ping Wang
Journal:  Analyst       Date:  2019-04-10       Impact factor: 4.616

2.  Colorimetric determination of BCR/ABL fusion genes using a nanocomposite consisting of Au@Pt nanoparticles covered with a PAMAM dendrimer and acting as a peroxidase mimic.

Authors:  Yang Peng; Huawei Shen; Sitian Tang; Zhenglan Huang; Yixiong Hao; Zhenhong Luo; Fangzhu Zhou; Teng Wang; Wenli Feng
Journal:  Mikrochim Acta       Date:  2018-08-04       Impact factor: 5.833

3.  A simple and compact smartphone-based device for the quantitative readout of colloidal gold lateral flow immunoassay strips.

Authors:  Wei Xiao; Caihong Huang; Fei Xu; Junjie Yan; Hongfen Bian; Qiangqiang Fu; Kaixin Xie; Lei Wang; Yong Tang
Journal:  Sens Actuators B Chem       Date:  2018-03-20       Impact factor: 7.460