Literature DB >> 27237438

Novel Cadmium Zinc Telluride Devices for Myocardial Perfusion Imaging-Technological Aspects and Clinical Applications.

Simona Ben-Haim1, John Kennedy2, Zohar Keidar2.   

Abstract

Myocardial perfusion imaging plays an important role in the assessment of patients with known or suspected coronary artery disease and is well established for diagnosis and for prognostic evaluation in these patients. The dedicated cardiac SPECT cameras with solid-state cadmium zinc telluride (CZT) detectors were first introduced a decade ago. A large body of evidence is building up, showing the superiority of the new technology compared with conventional gamma cameras. Not only the CZT detectors, but also new collimator geometries, the ability to perform focused imaging optimized for the heart and advances in data processing algorithms all contribute to the significantly improved sensitivity up to 8-10 times, as well as improved energy resolution and improved reconstructed spatial resolution compared with conventional technology. In this article, we provide an overview of the physical characteristics of the CZT cameras, as well as a review of the literature published so far, including validation studies in comparison with conventional myocardial perfusion imaging and with invasive coronary angiography, significant reduction in radiation dose, and new imaging protocols enabled by the new technology.
Copyright © 2016 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27237438     DOI: 10.1053/j.semnuclmed.2016.01.002

Source DB:  PubMed          Journal:  Semin Nucl Med        ISSN: 0001-2998            Impact factor:   4.446


  5 in total

1.  Update of the Brazilian Guideline on Nuclear Cardiology - 2020.

Authors:  Luiz Eduardo Mastrocola; Barbara Juarez Amorim; João Vicente Vitola; Simone Cristina Soares Brandão; Gabriel Blacher Grossman; Ronaldo de Souza Leão Lima; Rafael Willain Lopes; William Azem Chalela; Lara Cristiane Terra Ferreira Carreira; José Roberto Nolasco de Araújo; Cláudio Tinoco Mesquita; José Claudio Meneghetti
Journal:  Arq Bras Cardiol       Date:  2020-02       Impact factor: 2.000

2.  Feasibility study of a novel general purpose CZT-based digital SPECT camera: initial clinical results.

Authors:  Elinor Goshen; Leonid Beilin; Eli Stern; Tal Kenig; Ronen Goldkorn; Simona Ben-Haim
Journal:  EJNMMI Phys       Date:  2018-03-14

3.  Experimental evaluation of the GE NM/CT 870 CZT clinical SPECT system equipped with WEHR and MEHRS collimator.

Authors:  Toshimune Ito; Yohji Matsusaka; Masahisa Onoguchi; Hajime Ichikawa; Koichi Okuda; Takayuki Shibutani; Masaaki Shishido; Kozo Sato
Journal:  J Appl Clin Med Phys       Date:  2021-01-10       Impact factor: 2.102

Review 4.  Nuclear Imaging in Infective Endocarditis.

Authors:  Nidaa Mikail; Fabien Hyafil
Journal:  Pharmaceuticals (Basel)       Date:  2021-12-22

Review 5.  New Radionuclides and Technological Advances in SPECT and PET Scanners.

Authors:  Nicholas P van der Meulen; Klaus Strobel; Thiago Viana Miranda Lima
Journal:  Cancers (Basel)       Date:  2021-12-08       Impact factor: 6.639

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.