Literature DB >> 27232886

Stability and Degradation Mechanisms of Radiation-Grafted Polymer Electrolyte Membranes for Water Electrolysis.

Albert Albert1, Tim Lochner1, Thomas J Schmidt1,2, L Gubler1.   

Abstract

Radiation-grafted membranes are a promising alternative to commercial membranes for water electrolyzers, since they exhibit lower hydrogen crossover and area resistance, better mechanical properties, and are of potentially lower cost than perfluoroalkylsulfonic acid membranes, such as Nafion. Stability is an important factor in view of the expected lifetime of 40 000 h or more of an electrolyzer. In this study, combinations of styrene (St), α-methylstyrene (AMS), acrylonitrile (AN), and 1,3-diisopropenylbenzene (DiPB) are cografted into 50 μm preirradiated poly(ethylene-co-tetrafluoroethylene) (ETFE) base film, followed by sulfonation to produce radiation-grafted membranes. The stability of the membranes with different monomer combinations is compared under an accelerated stress test (AST), and the degradation mechanisms are investigated. To mimic the conditions in an electrolyzer, in which the membrane is always in contact with liquid water at elevated temperature, the membranes are immersed in water for 5 days at 90 °C, so-called thermal stress test (TST). In addition to testing in air atmosphere tests are also carried out under argon to investigate the effect of the absence of oxygen. The water is analyzed with UV-vis spectroscopy and ion chromatography. The ion exchange capacity (IEC), swelling degree, and Fourier transform infrared (FTIR) spectra of the membranes are compared before and after the test. Furthermore, energy-dispersive X-ray (EDX) spectroscopic analysis of the membrane cross-section is performed. Finally, the influence of the TST to the membrane area resistance and hydrogen crossover is measured. The stability increases along the sequence St/AN, St/AN/DiPB, AMS/AN, and AMS/AN/DiPB grafted membrane. The degradation at the weak-link, oxygen-induced degradation, and hydrothermal degradation are proposed in addition to the "swelling-induced detachment" reported in the literature. By mitigating the possible paths of degradation, the AMS/AN/DiPB grafted membrane is shown to be the most stable membrane and, therefore, it is a promising candidate for a membrane to be used in a water electrolyzer.

Entities:  

Keywords:  degradation; electrolyzer; fuel cell; hydrogen crossover; polymer electrolyte; radiation-grafted membranes; resistance; stability

Year:  2016        PMID: 27232886     DOI: 10.1021/acsami.6b03050

Source DB:  PubMed          Journal:  ACS Appl Mater Interfaces        ISSN: 1944-8244            Impact factor:   9.229


  3 in total

1.  Preparation and Characterization of PVA Alkaline Solid Polymer Electrolyte with Addition of Bamboo Charcoal.

Authors:  Lidan Fan; Mengyue Wang; Zhen Zhang; Gang Qin; Xiaoyi Hu; Qiang Chen
Journal:  Materials (Basel)       Date:  2018-04-26       Impact factor: 3.623

2.  Anatomies for the thermal decomposition behavior and product rule of 5,5'-dinitro-2H,2H'-3,3'-bi-1,2,4-triazole.

Authors:  Ruiqi Lyu; Zhiyu Huang; Hongbo Deng; Yue Wei; Chuanlin Mou; Linyuan Wang
Journal:  RSC Adv       Date:  2021-12-17       Impact factor: 3.361

3.  Unveiling the multiscale morphology of chemically stabilized proton exchange membranes for fuel cells by means of Fourier and real space studies.

Authors:  Natacha Huynh; João Paulo Cosas Fernandes; Vincent H Mareau; Laurent Gonon; Stéphanie Pouget; Pierre-Henri Jouneau; Lionel Porcar; Hakima Mendil-Jakani
Journal:  Nanoscale Adv       Date:  2021-03-23
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.