Literature DB >> 27231953

Preparation of [(68)Ga]PSMA-11 for PET-CT imaging using a manual synthesis module and organic matrix based (68)Ge/(68)Ga generator.

Raviteja Nanabala1, Muhammed K Anees1, Arun Sasikumar1, Ajith Joy1, M R A Pillai2.   

Abstract

INTRODUCTION: [(68)Ga]PSMA-11 is a relatively recently introduced radiopharmaceutical for PET-CT imaging of prostate cancer patients. The availability of (68)Ge/(68)Ga generator and PSMA-11 ligand from commercial sources is facilitating the production of the radiopharmaceutical in-house. This paper describes our experience on the preparation of ~200 batches of [(68)Ga]PSMA-11 for conducting PET-CT imaging in patients suspected/suffering from prostate cancer.
METHODS: The radiosynthesis of [(68)Ga]PSMA-11 was done in a hospital based nuclear medicine department using (68)Ge/(68)Ga generator and a manual synthesis module, both supplied by Isotope Technologies Garching (ITG), Germany. The production involved the reaction of 5μg (5.3nmol) of PSMA-11 ligand in 1 ml of 0.25M sodium acetate buffer with 4ml of (68)GaCl3 in 0.05M HCl for 5min at 105°C; followed by purification in a C18 cartridge and collection through a 0.22μm pore size filter.
RESULTS: The radiochemical yields obtained were consistently high, 93.19%±3.76%, and there was hardly any batch failure. The radiochemical purity of the product was >99% and the product was stable for over 2h; however it was used in patients immediately after preparation. About 200 batches of [(68)Ga]PSMA-11 were prepared during the period and more than 300 patients received the tracer during the 14months of study. No adverse reaction was observed in any of the patients and the image qualities were consistent with literature reports.
CONCLUSION: [(68)Ga]PSMA-11 with high radiochemical and radionuclidic purity is conveniently prepared by using a (68)Ge/(68)Ga generator and manual synthesis module. The radiochemical yields are very high; and activity sufficient for 3-4 patients can be prepared in a single batch; multiple batches can be done on the same day and when needed after a gap of 1.5-2h.
Copyright © 2016 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  (68)Ga-PSMA-11; (68)Ge/(68)Ga generator; PET–CT imaging; PSMA inhibitor; Prostate cancer; Radiolabeling

Mesh:

Substances:

Year:  2016        PMID: 27231953     DOI: 10.1016/j.nucmedbio.2016.05.006

Source DB:  PubMed          Journal:  Nucl Med Biol        ISSN: 0969-8051            Impact factor:   2.408


  11 in total

1.  Head to head comparison performance of 99mTc-EDDA/HYNIC-iPSMA SPECT/CT and 68Ga-PSMA-11 PET/CT a prospective study in biochemical recurrence prostate cancer patients.

Authors:  Francisco Osvaldo García-Pérez; Jenny Davanzo; Sergio López-Buenrostro; Clara Santos-Cuevas; Guillermina Ferro-Flores; Miguel A Jímenez-Ríos; Anna Scavuzzo; Zael Santana-Ríos; Sevastián Medina-Ornelas
Journal:  Am J Nucl Med Mol Imaging       Date:  2018-10-20

2.  Synthesis and Initial Biological Evaluation of Boron-Containing Prostate-Specific Membrane Antigen Ligands for Treatment of Prostate Cancer Using Boron Neutron Capture Therapy.

Authors:  Sinan Wang; Charles Blaha; Raquel Santos; Tony Huynh; Thomas R Hayes; Denis R Beckford-Vera; Joseph E Blecha; Andrew S Hong; Miko Fogarty; Thomas A Hope; David R Raleigh; David M Wilson; Michael J Evans; Henry F VanBrocklin; Tomoko Ozawa; Robert R Flavell
Journal:  Mol Pharm       Date:  2019-08-16       Impact factor: 4.939

3.  Accuracy of 68Ga-PSMA-11 PET/CT and multiparametric MRI for the detection of local tumor and lymph node metastases in early biochemical recurrence of prostate cancer.

Authors:  Maija Radzina; Mara Tirane; Lilita Roznere; Liene Zemniece; Laura Dronka; Marika Kalnina; Edgars Mamis; Juergen Biederer; Vilnis Lietuvietis; Arvis Freimanis; Egils Vjaters
Journal:  Am J Nucl Med Mol Imaging       Date:  2020-04-15

4.  Diagnostic Accuracy of 68Ga-PSMA-11 PET/MRI Compared with Multiparametric MRI in the Detection of Prostate Cancer.

Authors:  Robert M Hicks; Jeffry P Simko; Antonio C Westphalen; Hao G Nguyen; Kirsten L Greene; Li Zhang; Peter R Carroll; Thomas A Hope
Journal:  Radiology       Date:  2018-09-18       Impact factor: 11.105

5.  Optimized Application of 68Ga-Prostate-Specific Membrane Antigen-617 Whole-Body PET/CT and Pelvic PET/MR in Prostate Cancer Initial Diagnosis and Staging.

Authors:  Chunxia Qin; Yongkang Gai; Qingyao Liu; Weiwei Ruan; Fang Liu; Fan Hu; Xiaoping Zhang; Xiaoli Lan
Journal:  Front Med (Lausanne)       Date:  2021-05-13

6.  Preparation of 68Ga-PSMA-11 with a Synthesis Module for Micro PET-CT Imaging of PSMA Expression during Prostate Cancer Progression.

Authors:  Yuebing Wang; Guoqiang Shao; Jianping Wu; Can Cui; Shimin Zang; Fan Qiu; Ruipeng Jia; Zizheng Wang; Feng Wang
Journal:  Contrast Media Mol Imaging       Date:  2018-04-26       Impact factor: 3.161

7.  Automated radiosynthesis of [68 Ga]Ga-PSMA-11 and [177 Lu]Lu-PSMA-617 on the iPHASE MultiSyn module for clinical applications.

Authors:  Christian W Wichmann; Uwe Ackermann; Stan Poniger; Kenneth Young; Benjamin Nguyen; Gordon Chan; John Sachinidis; Andrew M Scott
Journal:  J Labelled Comp Radiopharm       Date:  2020-11-02       Impact factor: 1.921

8.  Correlation between Intraprostatic PSMA Uptake and MRI PI-RADS of [68Ga]Ga-PSMA-11 PET/MRI in Patients with Prostate Cancer: Comparison of PI-RADS Version 2.0 and PI-RADS Version 2.1.

Authors:  Jing Zhao; Dilyana B Mangarova; Julia Brangsch; Avan Kader; Bernd Hamm; Winfried Brenner; Marcus R Makowski
Journal:  Cancers (Basel)       Date:  2020-11-26       Impact factor: 6.639

9.  Standardization of the [68Ga]Ga-PSMA-11 Radiolabeling Protocol in an Automatic Synthesis Module: Assessments for PET Imaging of Prostate Cancer.

Authors:  Leonardo L Fuscaldi; Danielle V Sobral; Ana Claudia R Durante; Fernanda F Mendonça; Ana Cláudia C Miranda; Marcelo L da Cunha; Luciana Malavolta; Jorge Mejia; Marycel F de Barboza
Journal:  Pharmaceuticals (Basel)       Date:  2021-04-21

10.  Scatter Artifact with Ga-68-PSMA-11 PET: Severity Reduced With Furosemide Diuresis and Improved Scatter Correction.

Authors:  Courtney Lawhn-Heath; Robert R Flavell; David E Korenchan; Timothy Deller; Spencer Lake; Peter R Carroll; Thomas A Hope
Journal:  Mol Imaging       Date:  2018 Jan-Dec       Impact factor: 4.488

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.