Literature DB >> 27230474

Analysis of accuracy in optical motion capture - A protocol for laboratory setup evaluation.

Patric Eichelberger1, Matteo Ferraro2, Ursina Minder2, Trevor Denton3, Angela Blasimann2, Fabian Krause4, Heiner Baur2.   

Abstract

Validity and reliability as scientific quality criteria have to be considered when using optical motion capture (OMC) for research purposes. Literature and standards recommend individual laboratory setup evaluation. However, system characteristics such as trueness, precision and uncertainty are often not addressed in scientific reports on 3D human movement analysis. One reason may be the lack of simple and practical methods for evaluating accuracy parameters of OMC. A protocol was developed for investigating the accuracy of an OMC system (Vicon, volume 5.5×1.2×2.0m(3)) with standard laboratory equipment and by means of trueness and uncertainty of marker distances. The study investigated the effects of number of cameras (6, 8 and 10), measurement height (foot, knee and hip) and movement condition (static and dynamic) on accuracy. Number of cameras, height and movement condition affected system accuracy significantly. For lower body assessment during level walking, the most favorable setting (10 cameras, foot region) revealed mean trueness and uncertainty to be -0.08 and 0.33mm, respectively. Dynamic accuracy cannot be predicted based on static error assessments. Dynamic procedures have to be used instead. The significant influence of the number of cameras and the measurement location suggests that instrumental errors should be evaluated in a laboratory- and task-specific manner. The use of standard laboratory equipment makes the proposed procedure widely applicable and it supports the setup process of OCM by simple functional error assessment. Careful system configuration and thorough measurement process control are needed to produce high-quality data.
Copyright © 2016 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Accuracy; Measurement error; Optical motion capture; Precision; Uncertainty

Mesh:

Year:  2016        PMID: 27230474     DOI: 10.1016/j.jbiomech.2016.05.007

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  15 in total

1.  Step descent strategy is altered bilaterally despite unilateral muscle strength impairment after total knee arthroplasty.

Authors:  Paul W Kline; Cale A Jacobs; Stephen T Duncan; Brian Noehren
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2019-06-14       Impact factor: 4.114

2.  A new 2D-3D registration gold-standard dataset for the hip joint based on uncertainty modeling.

Authors:  Fabio D'Isidoro; Christophe Chênes; Stephen J Ferguson; Jérôme Schmid
Journal:  Med Phys       Date:  2021-08-17       Impact factor: 4.506

3.  Hardware in the Loop Performance Assessment of LIDAR-Based Spacecraft Pose Determination.

Authors:  Roberto Opromolla; Giancarmine Fasano; Giancarlo Rufino; Michele Grassi
Journal:  Sensors (Basel)       Date:  2017-09-24       Impact factor: 3.576

4.  EquiMoves: A Wireless Networked Inertial Measurement System for Objective Examination of Horse Gait.

Authors:  Stephan Bosch; Filipe Serra Bragança; Mihai Marin-Perianu; Raluca Marin-Perianu; Berend Jan van der Zwaag; John Voskamp; Willem Back; René van Weeren; Paul Havinga
Journal:  Sensors (Basel)       Date:  2018-03-13       Impact factor: 3.576

5.  Effectiveness of an interactive telerehabilitation system with home-based exercise training in patients after total hip or knee replacement: study protocol for a multicenter, superiority, no-blinded randomized controlled trial.

Authors:  Sarah Eichler; Sophie Rabe; Annett Salzwedel; Steffen Müller; Josefine Stoll; Nina Tilgner; Michael John; Karl Wegscheider; Frank Mayer; Heinz Völler
Journal:  Trials       Date:  2017-09-21       Impact factor: 2.279

6.  On the Noise Complexity in an Optical Motion Capture Facility.

Authors:  Przemysław Skurowski; Magdalena Pawlyta
Journal:  Sensors (Basel)       Date:  2019-10-13       Impact factor: 3.576

7.  Treadmill-to-Overground Mapping of Marker Trajectory for Treadmill-Based Continuous Gait Analysis.

Authors:  Woo Chang Jung; Jung Keun Lee
Journal:  Sensors (Basel)       Date:  2021-01-25       Impact factor: 3.576

8.  Examining Different Motor Learning Paradigms for Improving Balance Recovery Abilities Among Older Adults, Random vs. Block Training-Study Protocol of a Randomized Non-inferiority Controlled Trial.

Authors:  Hadas Nachmani; Inbal Paran; Moti Salti; Ilan Shelef; Itshak Melzer
Journal:  Front Hum Neurosci       Date:  2021-02-25       Impact factor: 3.169

9.  A minimal markerset for three-dimensional foot function assessment: measuring navicular drop and drift under dynamic conditions.

Authors:  Patric Eichelberger; Angela Blasimann; Nicole Lutz; Fabian Krause; Heiner Baur
Journal:  J Foot Ankle Res       Date:  2018-04-18       Impact factor: 2.303

10.  Moving system with action sport cameras: 3D kinematics of the walking and running in a large volume.

Authors:  Gustavo R D Bernardina; Tony Monnet; Pietro Cerveri; Amanda P Silvatti
Journal:  PLoS One       Date:  2019-11-12       Impact factor: 3.240

View more