Literature DB >> 27230385

A user report on the trial use of gesture commands for image manipulation and X-ray acquisition.

Ellis Chun Fai Li1, Christopher Wai Keung Lai2.   

Abstract

Touchless environment for image manipulation and X-ray acquisition may enhance the current infection control measure during X-ray examination simply by avoiding any touch on the control panel. The present study is intended at designing and performing a trial experiment on using motion-sensing technology to perform image manipulation and X-ray acquisition function (the activities a radiographer frequently performs during an X-ray examination) under an experimental setup. Based on the author's clinical experience, several gesture commands were designed carefully to complete a single X-ray examination. Four radiographers were randomly recruited for the study. They were asked to perform gesture commands in front of a computer integrated with a gesture-based touchless controller. The translational movements of the tip of their thumb and index finger while performing different gesture commands were recorded for analysis. Although individual operators were free to decide the extent of movement and the speed at which their fingers and thumbs moved while performing these gesture commands, the result of our study demonstrated that all operators could perform our proposed gesture commands with good consistency, suggesting that motion-sensing technology could, in practice, be integrated into radiographic examinations. To summarize, although the implementation of motion-sensing technology as an input command in radiographic examination might inevitably slow down the examination throughput considering that extra procedural steps are required to trigger specific gesture commands in sequence, it is advantageous in minimizing the potential of the pathogen contamination during image operation and image processing that leads to cross infection.

Entities:  

Keywords:  Gesture command; Infection control; Motion-sensing technology; Radiology department

Mesh:

Year:  2016        PMID: 27230385     DOI: 10.1007/s12194-016-0358-1

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  9 in total

Review 1.  The severe acute respiratory syndrome.

Authors:  Joseph S M Peiris; Kwok Y Yuen; Albert D M E Osterhaus; Klaus Stöhr
Journal:  N Engl J Med       Date:  2003-12-18       Impact factor: 91.245

2.  Development of an image operation system with a motion sensor in dental radiology.

Authors:  Mitsuru Sato; Toshihiro Ogura; Yoshiaki Yasumoto; Yuta Kadowaki; Norio Hayashi; Kunio Doi
Journal:  Radiol Phys Technol       Date:  2015-04-21

3.  Development of a novel method for manipulation of angiographic images by use of a motion sensor in operating rooms.

Authors:  Toshihiro Ogura; Mitsuru Sato; Yuki Ishida; Norio Hayashi; Kunio Doi
Journal:  Radiol Phys Technol       Date:  2014-03-08

4.  Lack of care giver hand contamination with endemic bacterial pathogens in a nursing home.

Authors:  E Larson; L Bobo; R Bennett; S Murphy; S T Seng; J T Choo; J Sisler
Journal:  Am J Infect Control       Date:  1992-02       Impact factor: 2.918

5.  Additional direct medical costs of nosocomial infections: an estimation from a cohort of patients in a French university hospital.

Authors:  C Defez; P Fabbro-Peray; M Cazaban; T Boudemaghe; A Sotto; J P Daurès
Journal:  J Hosp Infect       Date:  2008-01-16       Impact factor: 3.926

6.  Isolation of a novel coronavirus from a man with pneumonia in Saudi Arabia.

Authors:  Ali M Zaki; Sander van Boheemen; Theo M Bestebroer; Albert D M E Osterhaus; Ron A M Fouchier
Journal:  N Engl J Med       Date:  2012-10-17       Impact factor: 91.245

7.  Hospital outbreak of Middle East respiratory syndrome coronavirus.

Authors:  Abdullah Assiri; Allison McGeer; Trish M Perl; Connie S Price; Abdullah A Al Rabeeah; Derek A T Cummings; Zaki N Alabdullatif; Maher Assad; Abdulmohsen Almulhim; Hatem Makhdoom; Hossam Madani; Rafat Alhakeem; Jaffar A Al-Tawfiq; Matthew Cotten; Simon J Watson; Paul Kellam; Alimuddin I Zumla; Ziad A Memish
Journal:  N Engl J Med       Date:  2013-06-19       Impact factor: 91.245

8.  Analysis of the accuracy and robustness of the leap motion controller.

Authors:  Frank Weichert; Daniel Bachmann; Bartholomäus Rudak; Denis Fisseler
Journal:  Sensors (Basel)       Date:  2013-05-14       Impact factor: 3.576

9.  Contamination of X-ray cassettes with methicillin-resistant Staphylococcus aureus and methicillin-resistant Staphylococcus haemolyticus in a radiology department.

Authors:  Jae-Seok Kim; Han-Sung Kim; Ji-Young Park; Hyun-Sook Koo; Chul-Sun Choi; Wonkeun Song; Hyoun Chan Cho; Kyu Man Lee
Journal:  Ann Lab Med       Date:  2012-04-18       Impact factor: 3.464

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.