Sonography for Complete Evaluation of Neonatal Intensive Care Unit Central Support Devices: A Pilot Study.

David Saul1, Samuel Ajayi2, David L Schutzman2, Mindy M Horrow3.   

Abstract

OBJECTIVES: Neonates in the neonatal intensive care unit often require considerable support with endotracheal tubes, umbilical arterial and venous catheters, and peripherally inserted central venous catheters. Support device evaluation with radiography exposes neonates to ionizing radiation. This study evaluated the effectiveness of sonographic localization for endotracheal tubes, umbilical arterial and venous catheters, and peripherally inserted central venous catheters.
METHODS: This blinded prospective Institutional Review Board-approved, Health Insurance Portability and Accountability Act-compliant study with informed consent compared sonography to radiography for endotracheal tube, umbilical arterial and venous catheter, and peripherally inserted central venous catheter localization. Participants were consecutively recruited NICU patients of any weight, gestation, and chronologic age who had an endotracheal tube, umbilical arterial catheter, umbilical venous catheter, or peripherally inserted central venous catheter placed or adjusted and had subsequent radiographic confirmation within 24 hours. Sonographic evaluation was obtained as soon as possible, without prior review of the radiograph, and results were compared.
RESULTS: Thirty sonographic studies were performed in 25 patients (14 male and 11 female), for a total of 50 lines and tubes: 18 umbilical venous catheters, 12 umbilical arterial catheters, 11 peripherally inserted central venous catheters, and 9 endotracheal tubes. Forty-nine support devices (98%) were visualized with sonography, all concordant with radiography. Forty-four were correctly positioned, and 6 were malpositioned. Sonography identified the location of umbilical venous catheters in all 18 cases (100%), umbilical arterial catheters in all 12 (100%), peripherally inserted central venous catheters in 10 (91%), and endotracheal tubes in 9 (100%).
CONCLUSIONS: The effectiveness of sonography was excellent for evaluation of umbilical arterial and venous catheters, endotracheal tubes, and peripherally inserted central venous catheters. These results support the goal of further point-of-care training and accreditation to use sonography as a primary modality for complete evaluation of NICU support devices.

Entities:  

Keywords:  central venous catheter; endotracheal tube; neonate; pediatric ultrasound; sonography

Mesh:

Year:  2016        PMID: 27229130     DOI: 10.7863/ultra.15.06104

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  5 in total

1.  Adverse events associated with umbilical catheters: a systematic review and meta-analysis.

Authors:  Kim Gibson; Rebecca Sharp; Amanda Ullman; Scott Morris; Tricia Kleidon; Adrian Esterman
Journal:  J Perinatol       Date:  2021-07-16       Impact factor: 2.521

2.  Introduction of point of care ultrasound into the neonatal intensive care unit.

Authors:  Adam S Bauer; Ryan Meinen; Kelly Devous; Awni Al-Subu; Eileen Cowan
Journal:  J Ultrasound       Date:  2020-01-01

3.  Diagnostic accuracy of ultrasound for localising peripherally inserted central catheter tips in infants in the neonatal intensive care unit: a systematic review and meta-analysis.

Authors:  Shauna C Doyle; Niamh M Bergin; Rena Young; Andrew England; Mark F McEntee
Journal:  Pediatr Radiol       Date:  2022-05-05

Review 4.  Sonographic Evaluation of the Endotracheal Tube Position in the Neonatal Population: A Comprehensive Review and Meta-Analysis.

Authors:  Sabrina Congedi; Federica Savio; Maria Auciello; Sabrina Salvadori; Daniel Nardo; Luca Bonadies
Journal:  Front Pediatr       Date:  2022-06-02       Impact factor: 3.569

5.  Incidence of umbilical vein catheter-associated thrombosis of the portal system: A systematic review and meta-analysis.

Authors:  Iliana Bersani; Fiammetta Piersigilli; Giulia Iacona; Immacolata Savarese; Francesca Campi; Andrea Dotta; Cinzia Auriti; Enrico Di Stasio; Matteo Garcovich
Journal:  World J Hepatol       Date:  2021-11-27
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.