Literature DB >> 27225176

Threads for tear film collection and support in quantitative amino acid analysis.

Vitaly Avilov1, Qi Zeng1, Scott A Shippy2,3.   

Abstract

The collection of tears for chemical composition analysis is complicated by both the difficulty in sampling the tear film and the relatively low microliter volumes available for analysis. The experiments in this study are focused on the demonstration of a method for determining amino acids from tear samples. Phenol red thread was used to absorptively collect tear fluid for qualitative and quantitative analyses of amino acids in basal, reflex, and emotional tears. The thread is also used as a support for sample preparation followed by elution with a buffer. The phenol red indicator on the thread turns from yellow to red with 15-s tear absorption and allows accurate volume measurement from 100 nL to over 1 μL. Derivatization of amino acids was performed directly on the thread with primary amine reactive fluorescamine for fluorescence detection. Analyte elution was performed via centrifugation with the thread in a pipet tip suspended in a centrifuge tube. Collected tear eluate was analyzed via capillary electrophoresis with LED-induced fluorescence. Glycine, glutamate, and aspartate were baseline resolved and used for method characterization. Recoveries were at 50 % for a single derivation and elution step but average recoveries near 90 % were found with two-step processing. Glutamate and aspartate are shown to be stable stored on thread for 3 days. Basal, reflex, and emotional tears were analyzed from three subjects showing distinct amino acid profiles for each tear type. The demonstration of this method may facilitate the development of routine tear compositional analysis to assess ocular health. Graphical Abstract Schematic drawing of thread-based tear collection and quantitative analysis.

Entities:  

Keywords:  Amino acid; Capillary electrophoresis; Emotional tears; Phenol red thread; Reflex tears; Tear

Mesh:

Substances:

Year:  2016        PMID: 27225176     DOI: 10.1007/s00216-016-9624-7

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  2 in total

1.  An Extensive Study of Phenol Red Thread as a Novel Non-Invasive Tear Sampling Technique for Proteomics Studies: Comparison with Two Commonly Used Methods.

Authors:  Gábor Kecskeméti; Edit Tóth-Molnár; Tamás Janáky; Zoltán Szabó
Journal:  Int J Mol Sci       Date:  2022-08-03       Impact factor: 6.208

2.  Quantifying Sample Collection and Processing Impacts on Fiber-Based Tear Fluid Chemical Analysis.

Authors:  Anis Barmada; Scott A Shippy
Journal:  Transl Vis Sci Technol       Date:  2020-09-23       Impact factor: 3.283