Literature DB >> 27224562

Parameters Associated with Marginal Bone Loss around Implant after Prosthetic Loading.

Clarissa D Koller1, Tatiana Pereira-Cenci1, Noéli Boscato1.   

Abstract

This study evaluated retrospectively the association among occlusal, periodontal and implant-prosthetic parameters and marginal bone loss (MBL) around implants and survival rate at 5.7 ±3.2 years of follow-up after prosthetic loading. Eighty-two patients received 164 external hexagon implants. After the standard healing period (3 to 6 months), the implants were restored with single-tooth or up to three splinted crowns. All patients were followed according to a strict maintenance program with regular recalls and clinically evaluated by a calibrated examiner. The MBL measurements taken from standardized radiographs made at permanent crown placement (baseline) and after the last evaluation were calculated considering occlusal, periodontal and implant-prosthetic parameters. Veneer fractures and abutment loosening were not considered failure. Two implants failed during the follow-up period, resulting in a survival rate of 98.8%. Cox regression analyses showed MBL associated with non-working side contacts (p=0.047), inadequate anterior guidance (p=0.001), lateral group guidance involving teeth and implants (p=0.015), periimplant plaque index (p=0.035), prosthetic design (p=0.030) and retention (p=0.006). Inadequate occlusal pattern guide, presence of visible plaque, and cemented and splinted implant-supported restoration were associated with greater MBL around the implant.

Entities:  

Mesh:

Year:  2016        PMID: 27224562     DOI: 10.1590/0103-6440201600874

Source DB:  PubMed          Journal:  Braz Dent J        ISSN: 0103-6440


  8 in total

1.  Stresses induced by one piece and two piece dental implants in All-on-4® implant supported prosthesis under simulated lateral occlusal loading: non linear finite element analysis study.

Authors:  Ahmed Mostafa Abdelfattah Mohamed; Mohamed Gamal Askar; Mahmoud El-Moutassim Bellah El Homossany
Journal:  BMC Oral Health       Date:  2022-05-22       Impact factor: 3.747

2.  Guided bone regeneration simultaneous with implant placement using bovine-derived xenograft with and without liquid platelet-rich fibrin: a randomized controlled clinical trial.

Authors:  Gözde Işık; Meltem Özden Yüce; Nazan Koçak-Topbaş; Tayfun Günbay
Journal:  Clin Oral Investig       Date:  2021-05-28       Impact factor: 3.573

3.  A comparison of peri-implant strain generated by different types of implant supported prostheses.

Authors:  Ipsha Rani; Jayakar Shetty; Vahini Reddy
Journal:  J Indian Prosthodont Soc       Date:  2017 Apr-Jun

4.  Comparison of stress in implant-supported monolithic zirconia fixed partial dentures between canine guidance and group function occlusal patterns: A finite element analysis.

Authors:  Mahmood Robati Anaraki; Ali Torab; Taymaz Mounesi Rad
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2019-08-14

5.  Fractures of implant fixtures: a retroscccpective clinical study.

Authors:  Han-Chang Yu; Young-Kyun Kim
Journal:  Maxillofac Plast Reconstr Surg       Date:  2020-04-25

6.  Marginal Bone Loss around Implant-Retaining Overdentures versus Implant-Supported Fixed Prostheses 12-Month Follow-Up: A Retrospective Study.

Authors:  Odontuya Dorj; Chin-Kai Lin; Eisner Salamanca; Yu-Hwa Pan; Yi-Fan Wu; Yung-Szu Hsu; Jerry C-Y Lin; Hsi-Kuei Lin; Wei-Jen Chang
Journal:  Int J Environ Res Public Health       Date:  2022-02-03       Impact factor: 3.390

7.  Long-Term Fatigue and Its Probability of Failure Applied to Dental Implants.

Authors:  María Prados-Privado; Juan Carlos Prados-Frutos; Sérgio Alexandre Gehrke; Mariano Sánchez Siles; José Luis Calvo Guirado; José Antonio Bea
Journal:  Biomed Res Int       Date:  2016-07-19       Impact factor: 3.411

8.  Marginal bone loss around cement and screw-retained fixed implant prosthesis.

Authors:  Muhammad-Hasan Hameed; Farhan-Raza Khan; Robia Ghafoor; Syed-Iqbal Azam
Journal:  J Clin Exp Dent       Date:  2018-10-01
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.