Dual-Energy CT Characteristics of Parathyroid Adenomas on 25-and 55-Second 4D-CT Acquisitions: Preliminary Experience.

Reza Forghani1, Michael Roskies, Xiaoyang Liu, Xianming Tan, Alex Mlynarek, Richard J Payne, Jaykumar R Nair, Michael P Hier, Mark Levental.   

Abstract

OBJECTIVE: The objective of this study was to compare the dual-energy computed tomography (CT) characteristics of parathyroid adenomas (PAs), thyroid tissue, and lymph nodes (LNs) and assess whether the spectral information can improve distinction of these tissues.
METHODS: Dual-energy CT scans from 20 patients with pathologically proven PAs were retrospectively evaluated, identifying 19 eligible PAs and region of interest analysis used for spectral characterization.
RESULTS: There was a significant difference in multiple spectral parameters between PAs, LNs, and the thyroid gland (P < 0.05-0.0001). The greatest difference in spectral characteristics of PAs compared with that of LNs was on the 25-second acquisition, whereas the 55-second acquisition was better for distinguishing PAs from the thyroid gland.
CONCLUSIONS: Four-dimensional CT acquired in dual-energy CT mode has the potential to further enhance diagnostic accuracy for PA identification on individual phases of the perfusion study.

Entities:  

Mesh:

Year:  2016        PMID: 27224226     DOI: 10.1097/RCT.0000000000000442

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  5 in total

1.  Spectral multi-energy CT texture analysis with machine learning for tissue classification: an investigation using classification of benign parotid tumours as a testing paradigm.

Authors:  Eiman Al Ajmi; Behzad Forghani; Caroline Reinhold; Maryam Bayat; Reza Forghani
Journal:  Eur Radiol       Date:  2018-01-02       Impact factor: 5.315

2.  Dual-energy computed tomography of the neck-optimizing tube current settings and radiation dose using a 3D-printed patient phantom.

Authors:  Torsten Diekhoff; Michael Scheel; Wiebke Kress; Bernd Hamm; Paul Jahnke
Journal:  Quant Imaging Med Surg       Date:  2021-04

3.  Detection of parathyroid adenomas with multiphase 4DCT: towards a true four-dimensional technique.

Authors:  Steven Raeymaeckers; Yannick De Brucker; Tim Vanderhasselt; Nico Buls; Johan De Mey
Journal:  BMC Med Imaging       Date:  2021-04-07       Impact factor: 1.930

Review 4.  4DCT Scanning Technique for Primary Hyperparathyroidism: A Scoping Review.

Authors:  Steven Raeymaeckers; Maurizio Tosi; Johan De Mey
Journal:  Radiol Res Pract       Date:  2021-05-21

Review 5.  Dual-Energy CT in Head and Neck Imaging.

Authors:  Elise D Roele; Veronique C M L Timmer; Lauretta A A Vaassen; Anna M J L van Kroonenburgh; A A Postma
Journal:  Curr Radiol Rep       Date:  2017-03-29