Literature DB >> 27222824

Ultra-high-pressure liquid chromatography tandem mass spectrometry method for the determination of 9 organophosphate flame retardants in water samples.

María Lorenzo1, Julián Campo2, Yolanda Picó1.   

Abstract

Few methods are available for comprehensive organophosphate flame retardants (PFRs) detection in water and wastewater. Gas chromatography has been employed previously, but this approach is less selective, not amenable for use with deuterated standards and can suffer unfavorable fragmentation. Ultra-high-pressure liquid chromatography tandem mass spectrometry (UHPLC-QqQ-MS/MS) has become the most promising platform, already applied successfully for analysis of selected PFRs in some environmental matrices like water and wastewater. However, the presence of some interferences from the dissolvent, the equipment and the used materials should be taken into account. The procedure involves: •The first determination of PFRs by UHPLC-QqQ-MS/MS using a trap column to distinguish the interferences coming from the instrument and mobile phases.•The optimization of the LC separation to distinguish all target compounds and their interferences.•This method coupled to a solid-phase extraction (SPE) improve the detection and quantification of PFRs.

Entities:  

Keywords:  Analysis of organophosphate flame retardants in water by SPE and UHPLC–MS/MS using a trap column.; Interferences; LC–MS/MS; Organophosphate flame retardants; Trap column; Water; solid phase extraction

Year:  2016        PMID: 27222824      PMCID: PMC4865636          DOI: 10.1016/j.mex.2016.04.006

Source DB:  PubMed          Journal:  MethodsX        ISSN: 2215-0161


Method details

Interference analysis

Ultra-high-pressure liquid chromatography tandem mass spectrometry (UHPLC-QqQ-MS/MS) is likely the most promising platform for the determination of PFRs in water and wastewater matrices [1], [2], [3], [4], [5]. However, the presence of some interferences from the dissolvent, the equipment and the laboratory material can disturb their analytical determination. We made, up to our knowledge, the first determination of PFRs using a trap column to distinguish these interferences. Furthermore, we prove two different solvents, acetonitrile (ACN) and methanol (MeOH), observing the presence of analyte’s contamination in both cases. The system is applied to the determination of PFR in water. Fig. 1, Fig. 2 present chromatograms of a non-spiked river sample and the same sample spiked with the analytes.
Fig. 1

Chromatogram of a river sample.

Fig. 2

Chromatogram of the previous river sample spiked at 500 ng/mL.

Reagents and samples

Compounds: the nine PFRs and the four deuterated PFRs used as internal standard (IS) (Table 1) were purchased from LGC Standards (Germany).
Table 1

List of the compounds name, acronym and formula.

CompoundsAcronymFormulaCAS number
Tris(2-chloroethyl) phosphateTCEPC6H12Cl3O4P115-96-8
Tri-n-propylphosphateTPPC9H21O4P513-08-6
Tris(2-chloroisopropyl)phosphateTClPPC9H18Cl3O4P13674-84-5
Tris(1,3-dichloro-2-propyl)phosphateTDClPPC9H15Cl6O4P13674-87-8
Triphenyl phosphateTPhPC18H15O4P115-86-6
Cresyl diphenyl phosphateCDPC19H17O4P26444-49-5
Tris(2,3-dibromopropyl)phosphateTDBPPC9H15Br6O4P126-72-7
TricresylphosphateTMPPC21H21O4P1330-78-5
Tris-(2-ethylhexyl)phosphateTEHPC24H51O4P78-42-2
Triphenyl phosphate D15 (IS)M-TPHPC18D15O4P1173020-30-8
Tris(1,3-dichloro-2-propyl) phosphate D15 (IS)M-TDCIPPC9D15Cl6O4PNot available
Tris-(2-chloroethyl) phosphate D12 (IS)M-TCEPC6D12Cl3O4P115-96-8
Tris(2-chloroisopropyl) phosphate D18 (IS)M-TCIPPC9D18Cl3O4P13674-84-5
Solvents: methanol (MeOH), dichloromethane (DCM) and acetonitrile (ACN) were bought from VWR (Radnor, PA, USA) and formic acid from AMRESCO (Solon, OH, USA), all of them were of analytical quality. Ultra-pure water: prepared with Milli-Q SP Reagent Water System from Millipore (Bedford, MA, USA). Standard solutions: individual solutions (1 mg/mL) were prepared by dissolving the PFRs in MeOH. Mixed stock solutions containing 10000 ng/mL and 100 ng/mL of each of the nine PFRs were prepared by dilution of the stock solutions with MeOH. Stock and mixed standard solutions were stored in polypropylene tubes at 4 °C. Samples: water samples were obtained from the Turia River (May 2015) from the influent and the effluent of the wastewater treatment plant (WWTP) of Pinedo (March 2015), both near the city of Valencia (Spain). Influent wastewater samples were filtered under vacuum using the ADVANTEC® filters to remove the particulate matter. Analysis of spiked samples and blanks were made in triplicate.

Optimization of sample extraction

Put the Phenomenex Strata-X 33u Polymeric Reversed Phase (200 mg/6 mL) cartridges (Phenomenex, Torrance, Ca, USA) into a 12 port vacuum manifold Supelco Visiprep 57030-U de Sigma-Aldrich (St. Louis, MO, EEUU). Precondition the cartridge with 6 mL MeOH:DCM (1:1 v/v), 6 mL of MeOH and 6 mL of water, with 350 mba/h·PA vacuum. Pass the water samples through the cartridges under previous vacuum at a flow rate of 10 mL/min. Dry the cartridges under vacuum for 15 min. Elute the analytes on a 15 mL Falcon tube VWR (Radnor, PA, USA) with 10 mL of MeOH:DCM (50:50 v/v). Evaporate the extracts to dryness at 40 °C using a combined sample concentrator model SBHCONC/1 and a heating plate model SBH130D/3 both manufactured by Stuart (Stafford, UK). Redissolve the residue in 1 mL of methanol by agitation and ultrasonication for 1 min and pass the extract to 2 mL amber vials with 250 μL insert polypropylene 100/PK + Septum Sil/PTFE, both manufactured by Análisis Vínicos S.L. (Tomelloso, Spain).

Instrumentation

The analysis was performed using: UHPLC-QqQ-MS/MS system: 1260 Infinity ultra-high-performance liquid chromatograph combined with a 6410 triple quadrupole mass spectrometer (MS/MS) with electrospray ionization (ESI) of Agilent Technologies (Santa Clara, CA, USA). LC column: Kinetex C18 (50 × 2.1 mm, 1.7 μm) from Phenomenex (Torrance, CA, EEUU). Trap column: Zorbax Eclipse Plus C18 (30 × 4.6 mm, 3.5 μm) from Agilent Technologies (Santa Clara, CA, USA). Place this column between the pump and the auto sampler. Mobile phases: (A) water and (B) methanol, both containing 0.1% of formic acid. Gradient: 0 min (30% B), 0.5 min (30% B), 12 min (95% B), 18 min (98% B) and 25 min (98% B) and return to the initial conditions. An equilibration time of 15 min was applied to stabilize the column conditions. Flow rate: 0.2 mL/min and the sample volume injected was 5 μL. Analysis: performed in positive ionization mode. Data acquisition: carried out in selected reaction monitoring (SRM) to identify and quantify using two precursor-product ion transitions, retention times, and the ratio of intensities between the two product ions. Fragmentor and collision energies were optimized for each compound individually (Table 2).
Table 2

Dynamic MRM conditions for UHPLC-QqQ-MS/MS determination of PFRs.

AcronymAssociated ISPrecursor IonProduct ionFragmentorCollision Energy
TCEPM-TCEP2879910015
28522310010
TPPM-TPhP225.1140.9843
225.198.98415
TClPPM-TClPP329998015
3271758010
TDClPPM-TDClPP432.999.18015
430.999.18015
TPhPM-TPhP327.1214.911727
327.1151.911743
CDPM-TPhP341.1151.916743
341.190.916739
TDBPPM-TDClPP698.698.912025
696.698.912025
TMPPM-TPhP369.1165.619231
369.19119243
TEHPM-TPhP435.498.91137
435.4711135
M-TPHP34216012047
3428212047
M-TDCIPP44810212015
44610212015
M-TCEP2996710020
2976710020
M-TCIPP34710210020
34510210020

In italics, the compounds used as IS.

Validation of the method

The validation of the instrumental parameters (Table 3) was performed by determining recoveries, limit of detection (LOD), limit of quantification (LOQ) and linearity over the range to obtain suitable R2. The quantification was performed using the internal standard method. The mixture of the internal standards was added to water to a concentration of 200 ng/L to get a final concentration in the injected extract of 50 ng/mL. The reported parameters were calculated from distilled, river and wastewater samples spiked with standard solutions prepared in methanol at the appropriate concentrations, in a way that the volume of organic solvent added were never higher than 250 μL. The samples were processed with plastic materials as much as possible to avoid adsorption to glass. There were not river or wastewater samples free of PFRs. Then, to perform these experiments several non-spiked samples were analyzed and the peak area of those compounds were subtracted to that found in the spiked samples.
Table 3

Recoveries and R2 values for calibration curves (n = 7), LODs and LOQs (ng/mL) and intra and inter-day precision.

AcronymRecoveriesR2LOD (ng/ml)LOQ (ng/ml)Intra-day precisionInter-day precision
TCEP98%0.9940.030.37.56.6
TPP95%0.9900.252.55.819.6
TClPP102%0.9900.252.53.06.6
TDClPP96%0.9900.030.34.18.2
TPhP96%0.9980.114.218.9
CDP94%0.9940.112.619.9
TDBPP99%0.9980.252.511.417.5
TMPP101%0.9900.113.218.6
TEHP106%0.9920.252.55.920.0
The LOD was calculated as the mass of analyte required to produce a signal-to-noise (S/N) ratio of 3:1 and the LOQ of 10:1. S/N ratios were calculated using MassHunter Workstation Software (GL Sciences, Tokyo, Japan). LODs and LOQs were estimated from water samples spiked at 4 ng/L for river water and at 100 ng/L in wastewater. Values reported in Table 3 are LODs and LOQs in the injected extracts that would correspond to LODs ranging from 0.12 to 1 ng/L and LOQs from 1.2 to 10 ng/L in water samples. The results obtained for the LODs and LOQs show that the proposed method is sensitive enough for the determination of the PFRs in water samples. The precision studies were carried out from the evaluation of intra-day and inter-day variations of the areas ratio between the analyte and its IS using water extracts suitably stored. The intra-day precision of peak areas ratio (five replicates at 400 ng/L), expressed by means of the percentage of relative standard deviation (%RSD (n = 5)) were lower than 11.4% and the inter-day precision (five replicates) were less than 20%. Recoveries were calculated from samples spiked at 400 ng/L analyzed in quintuplicate. The calibration of the LC–MS/MS was conducted using seven different concentrations (from the LOQ to 300 ng/mL) of PFR standard solutions in methanol with 50 ng/mL of each deuterated compound used as IS. The use of IS prevent the matrix effects The robustness of the method was clearly ascertained during the optimization procedure, by establishing the consequences of the deliberate introduction of minor reasonable variations (mostly different water volume analyzed, sample flow-rates during the extraction step, cartridge drying times and eluent composition) and by the similar results obtained checking different types of water. The results obtained from the variations of ±20% in the different parameters were not significantly different from those achieved by the validated method. These results proved that the proposed method was robust. Each 10 samples, one instrumental and one procedural blank were analyzed to serve as quality control. Samples analyzed shown clearly two peaks, the first one corresponding to the TClPP found in the river water and the second to the instrumental background, indicating background contamination from the injection system and tubing of the LC–MS/MS can be successfully separated from the sample contamination. Table 4 shows the performance of the system in water samples (river, influent and effluent wastewater).
Table 4

Analysis of 250 mL of the river water and the influent and effluent wastewater samples (ng/ml).

AcronymRiver waterInfluent wastewaterEffluent wastewater
TCEP<LOQ19.00.8
TPP4.0<LOQ<LOQ
TClPP72.5448.9134.6
TDClPP<LOQ24.420.5
TPhP5.620.29.7
CDP<LOQ298.523.7
TDBPP<LOQ393.97.3
TMPP<LOQ17.02.2
TEHP12.59.799.9
  5 in total

1.  Development of an ultra-high-performance liquid chromatography-tandem mass spectrometry method for high throughput determination of organophosphorus flame retardants in environmental water.

Authors:  Xiao-wei Wang; Jing-fu Liu; Yong-guang Yin
Journal:  J Chromatogr A       Date:  2011-07-25       Impact factor: 4.759

2.  Quantitative determination of 13 organophosphorous flame retardants and plasticizers in a wastewater treatment system by high performance liquid chromatography tandem mass spectrometry.

Authors:  Million B Woudneh; Jonathan P Benskin; Guanghui Wang; Richard Grace; M Coreen Hamilton; John R Cosgrove
Journal:  J Chromatogr A       Date:  2015-04-22       Impact factor: 4.759

3.  Liquid chromatography-tandem mass spectrometry determination of nonionic organophosphorus flame retardants and plasticizers in wastewater samples.

Authors:  Rosario Rodil; José Benito Quintana; Thorsten Reemtsma
Journal:  Anal Chem       Date:  2005-05-15       Impact factor: 6.986

4.  Liquid chromatography/tandem mass spectrometry determination of organophosphorus flame retardants and plasticizers in drinking and surface waters.

Authors:  Alessandro Bacaloni; Chiara Cavaliere; Patrizia Foglia; Manuela Nazzari; Roberto Samperi; Aldo Laganà
Journal:  Rapid Commun Mass Spectrom       Date:  2007       Impact factor: 2.419

5.  Determination of selected organophosphate esters in the aquatic environment of Austria.

Authors:  Elena Martínez-Carballo; Carmen González-Barreiro; Andrea Sitka; Sigrid Scharf; Oliver Gans
Journal:  Sci Total Environ       Date:  2007-09-19       Impact factor: 7.963

  5 in total
  1 in total

Review 1.  Spatiotemporal Distribution and Analysis of Organophosphate Flame Retardants in the Environmental Systems: A Review.

Authors:  Sinozuko Hope Bika; Abiodun Olagoke Adeniji; Anthony Ifeanyi Okoh; Omobola Oluranti Okoh
Journal:  Molecules       Date:  2022-01-17       Impact factor: 4.411

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.