Separation of collagen-bound and porous bone-water longitudinal relaxation in mice using a segmented inversion recovery zero-echo-time sequence.

Magda Marcon1, Daniel Keller1,2, Moritz C Wurnig1, Markus Weiger3, David Kenkel1, Christian Eberhardt1, Daniel Eberli2, Andreas Boss1.   

Abstract

PURPOSE: Cortical bone mechanical properties are related to the collagen-bound water (CBW) and pore water (PW) components of cortical bone. The study evaluates the feasibility of zero-echo-time imaging in mice in vivo for longitudinal relaxation time (T1) measurements in cortical bone and separation of CBW and PW components.
METHODS: Zero-echo-time data were acquired at 4.7 Tesla in six mice with 14 different inversion times (0-2,600 ms). Region-of-interest analysis was performed at level of femur diaphysis. The T1 of cortical bone and of CBW (T1cbw) and PW (T1pw) as well as the CBW fraction (cbwf) was computed using a mono-exponential and a bi-exponential fitting approach, respectively. The sum of the squared residuals (Res) to the fit was provided for both approaches.
RESULTS: For the mono-exponential model, mean T1 ± standard deviation (SD) was 1,057 ± 160 ms. The bi-exponential approach provided a reliable separation of two different bone-water components, with a mean T1cbw of 213 ± 95 ms, T1pw of 2,152 ± 894 ms, and cbwf of 7.4 ± 2.7 %. Lower Res was obtained with bi-exponential approach (P < 0.001), and Res mean values ± SD were 0.016 ± 0.007 (bi-exponential) and 0.033 ± 0.016 (mono-exponential).
CONCLUSION: Zero-echo-time imaging allows for longitudinal relaxation measurements of cortical bone in vivo in mice models, with a reliable separation of PW and CBW components using a bi-exponential curve fitting approach. Magn Reson Med 77:1909-1915, 2017.
© 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  cortical bone; longitudinal relaxation; mice; zero-echo-time imaging

Mesh:

Substances:

Year:  2016        PMID: 27221236     DOI: 10.1002/mrm.26277

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  3 in total

1.  T1 measurement of bound water in cortical bone using 3D adiabatic inversion recovery ultrashort echo time (3D IR-UTE) Cones imaging.

Authors:  Tan Guo; Yajun Ma; Saeed Jerban; Hyungseok Jang; Wei Zhao; Eric Y Chang; Min Chen; Graeme M Bydder; Jiang Du
Journal:  Magn Reson Med       Date:  2019-12-20       Impact factor: 4.668

2.  Bone hydration: How we can evaluate it, what can it tell us, and is it an effective therapeutic target?

Authors:  Rachel K Surowiec; Matthew R Allen; Joseph M Wallace
Journal:  Bone Rep       Date:  2021-12-21

3.  Assessment of iron nanoparticle distribution in mouse models using ultrashort-echo-time MRI.

Authors:  Andreas Boss; Laura Heeb; Divya Vats; Fabian H L Starsich; Alice Balfourier; Inge K Herrmann; Anurag Gupta
Journal:  NMR Biomed       Date:  2022-02-01       Impact factor: 4.478

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.