OBJECTIVES: To evaluate the clinical performance and survival of Enamic crowns placed in a prosthodontic dental practice.
METHODS: Thirty-five patients and 45 crowns were included in the study. At 1-year recall appointments, the restorations were examined for survival. At the 2-year recall appointment, all restorations were clinically evaluated by an independent evaluator for CDA clinical criteria. Kaplan-Meier method and a log-rank test were used to compare the survival of the restorations placed with resin and resin-modified glass ionomer (RMGI) cements.
RESULTS: Out of the 45 crowns that were followed, 2 were lost to follow-up by 1 year and 7 were lost to follow-up by 2 years. Severe complications were observed in 2 teeth by the 2-year follow-up and were recorded as failures due to recurrent decay, and an internal crack in the abutment tooth. There was no difference between the survival probability for crowns cemented with resin cement (96.8%) and with RMGI cements (92.9%) (p = 0.42), however, 1 out of the 14 crowns cemented with RMGI cement debonded. The crowns were evaluated according the CDA criteria with over 90% alfa scores for all categories aside from surface texture (86% alfa).
CONCLUSION: The estimated 2-year survival of Enamic crowns is >90%. CLINICAL SIGNIFICANCE: Based on the preliminary 2-year results achieved in a clinical practice, Enamic is a suitable material for full-coverage single-unit crowns. Further studies are necessary to evaluate the long term success. (J Esthet Restor Dent 28:231-237, 2016).
© 2016 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2016        PMID: 27219683     DOI: 10.1111/jerd.12206

Source DB:  PubMed          Journal:  J Esthet Restor Dent        ISSN: 1496-4155            Impact factor:   2.843


  4 in total

1.  Polymer-infiltrated ceramic CAD/CAM inlays and partial coverage restorations: 3-year results of a prospective clinical study over 5 years.

Authors:  F A Spitznagel; K J Scholz; J R Strub; K Vach; P C Gierthmuehlen
Journal:  Clin Oral Investig       Date:  2017-12-06       Impact factor: 3.573

2.  Potential complications of CAD/CAM-produced resin composite crowns on molars: A retrospective cohort study over four years.

Authors:  Miyu Inomata; Akio Harada; Shin Kasahara; Taro Kusama; Akane Ozaki; Yusuke Katsuda; Hiroshi Egusa
Journal:  PLoS One       Date:  2022-04-07       Impact factor: 3.240

Review 3.  Ceramic Materials and Technologies Applied to Digital Works in Implant-Supported Restorative Dentistry.

Authors:  Se-Wook Pyo; Dae-Joon Kim; Jung-Suk Han; In-Sung Luke Yeo
Journal:  Materials (Basel)       Date:  2020-04-22       Impact factor: 3.623

4.  Effect of universal adhesives on microtensile bond strength to hybrid ceramic.

Authors:  Mohamed M Awad; Lamees Albedaiwi; Ahmed Almahdy; Rawaiz Khan; Nick Silikas; Muhanad M Hatamleh; Fahad M Alkhtani; Ali Alrahlah
Journal:  BMC Oral Health       Date:  2019-08-06       Impact factor: 2.757

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.