Literature DB >> 27219679

Comparison of two fabricated aptasensors based on modified carbon paste/oleic acid and magnetic bar carbon paste/Fe3O4@oleic acid nanoparticle electrodes for tetracycline detection.

Shahriar Jahanbani1, Ali Benvidi2.   

Abstract

In this research, we have improved two aptasensors based on a modified carbon paste electrode (CPE) with oleic acid (OA), and a magnetic bar carbon paste electrode (MBCPE) with Fe3O4 magnetic nanoparticles and oleic acid (OA). After the immobilization process of anti-TET at the electrode surfaces, the aptasensors were named CPE/OA/anti-TET and MBCPE/Fe3O4NPs/OA/anti-TET respectively. In this paper, the detection of tetracycline is compared using CPE/OA/anti-TET and MBCPE/Fe3O4NPs/OA/anti-TET aptasensors. These modified electrodes were characterized by infrared spectroscopy (IR), scanning electron microscopy (SEM), electrochemical impedance spectroscopy (EIS), UV-vis spectroscopy, and voltammetric methods. The linear range and the detection limit for TET with the CPE/OA/anti-TET aptasensor were found to be 1.0×10(-12)-1.0×10(-7)M and 3.0×10(-13)M respectively by EIS method. The linear range and the detection limit for TET with the CPE/OA/anti-TET aptasensor were found to be 1.0×10(-10)-1.0×10(-7)M with a limit of detection of 2.9×10(-11)M using differential pulse voltammetry (DPV) technique. The MBCPE/Fe3O4NPs/OA/anti-TET aptasensor was used for determination of TET, and a liner range of 1.0×10(-14)-1.0×10(-6)M with a detection limit of 3.8×10(-15)M was obtained by EIS method. Also, the linear range and detection limit of 1.0×10(-12)-1.0×10(-6)M and 3.1×10(-13)M respectively, were obtained for MBCPE/Fe3O4NPs/OA/anti-TET aptasensor using DPV. The proposed aptasensors were applied for determination of tetracycline in some real samples such as drug, milk, honey and blood serum samples.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Aptamer; Electrochemical impedance spectroscopy; Fe(3)O(4) magnetic nanoparticles; Immobilization; Magnetic bar carbon paste electrode; Tetracycline

Mesh:

Substances:

Year:  2016        PMID: 27219679     DOI: 10.1016/j.bios.2016.05.052

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  11 in total

1.  Development of an electrochemical biosensor for impedimetric detection of tetracycline in milk.

Authors:  Ayat Mohammad-Razdari; Mahdi Ghasemi-Varnamkhasti; Sajad Rostami; Zahra Izadi; Ali A Ensafi; Maryam Siadat
Journal:  J Food Sci Technol       Date:  2020-05-09       Impact factor: 2.701

2.  Electrochemically reduced graphene oxide/Cu-MOF/Pt nanoparticles composites as a high-performance sensing platform for sensitive detection of tetracycline.

Authors:  He Xu; Duo Zhang; Xueyu Weng; Dongfang Wang; Dongqing Cai
Journal:  Mikrochim Acta       Date:  2022-04-26       Impact factor: 5.833

Review 3.  Recent Advances and Perspectives on the Sources and Detection of Antibiotics in Aquatic Environments.

Authors:  Yanbo Zeng; Fengqin Chang; Qi Liu; Lizeng Duan; Donglin Li; Hucai Zhang
Journal:  J Anal Methods Chem       Date:  2022-05-25       Impact factor: 2.594

Review 4.  Magnetic Nanoparticles for Antibiotics Detection.

Authors:  Cecilia Cristea; Mihaela Tertis; Ramona Galatus
Journal:  Nanomaterials (Basel)       Date:  2017-05-24       Impact factor: 5.076

Review 5.  Aptamer-Based Biosensors for Antibiotic Detection: A Review.

Authors:  Asol Mehlhorn; Parvaneh Rahimi; Yvonne Joseph
Journal:  Biosensors (Basel)       Date:  2018-06-11

6.  Electrochemical detection of urinary microRNAs via sulfonamide-bound antisense hybridisation.

Authors:  Daniel A Smith; Lucy J Newbury; Guido Drago; Timothy Bowen; James E Redman
Journal:  Sens Actuators B Chem       Date:  2017-12       Impact factor: 7.460

7.  Indirect Competitive Determination of Tetracycline Residue in Honey Using an Ultrasensitive Gold-Nanoparticle-Linked Aptamer Assay.

Authors:  Yan-Mei Sheng; Jian Liang; Jing Xie
Journal:  Molecules       Date:  2020-05-04       Impact factor: 4.411

Review 8.  Recent advances and challenges in electrochemical biosensors for emerging and re-emerging infectious diseases.

Authors:  Shalini Menon; Manna Rachel Mathew; Sonia Sam; K Keerthi; K Girish Kumar
Journal:  J Electroanal Chem (Lausanne)       Date:  2020-08-25       Impact factor: 4.464

Review 9.  Magneto-Impedance Biosensor Sensitivity: Effect and Enhancement.

Authors:  Abkar Sayad; Efstratios Skafidas; Patrick Kwan
Journal:  Sensors (Basel)       Date:  2020-09-12       Impact factor: 3.576

Review 10.  The Application of Nanomaterials for the Electrochemical Detection of Antibiotics: A Review.

Authors:  Norah Salem Alsaiari; Khadijah Mohammedsaleh M Katubi; Fatimah Mohammed Alzahrani; Saifeldin M Siddeeg; Mohamed A Tahoon
Journal:  Micromachines (Basel)       Date:  2021-03-15       Impact factor: 2.891

View more