Literature DB >> 27218705

Miniaturized Flow Stacked Immunoassay for Detecting Escherichia coli in a Single Step.

Evgeni Eltzov1, Robert S Marks1.   

Abstract

Commercially available systems that provide cost-effective, fast, simple, and portable solutions for health and environmental applications are few despite advancements in bioassays and biosensor research. We have developed a new system based on stacked membranes, each layer with a specific function. Samples were added onto the bottom-most layer, and as each layer becomes wet, the analyte pushes through to the next membrane layers. During migration, the analyte attaches with the corresponding antibody, itself conjugated with horseradish peroxidase (HRP) to produce a measurable signal. To prevent false positive results, blocking layer membranes are added to stop unbound antibodies from reaching the top membrane. Thus, only analyte/antibody-HRP complex will generate a signal. In order to prove this concept, Escherichia coli was used as the target analyte. After optimization, our immunoassay sensitivity was adjusted to 100 cells mL(-1). Different environmental water sources were also tested to demonstrate the sensitivity and specificity of our proposed stacked bioassay. Simplicity, low price, sensitivity, and modularity (capability to change to any target analyte) make this idea very promising for future commercialization.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27218705     DOI: 10.1021/acs.analchem.6b01034

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  7 in total

1.  Fast label-free identification of bacteria by synchronous fluorescence of amino acids.

Authors:  Yaniv Shlosberg; Yair Farber; Salah Hasson; Valery Bulatov; Israel Schechter
Journal:  Anal Bioanal Chem       Date:  2021-09-07       Impact factor: 4.142

Review 2.  Advanced biosensors for detection of pathogens related to livestock and poultry.

Authors:  Jasmina Vidic; Marisa Manzano; Chung-Ming Chang; Nicole Jaffrezic-Renault
Journal:  Vet Res       Date:  2017-02-21       Impact factor: 3.683

Review 3.  Point-of-Care-Testing in Acute Stroke Management: An Unmet Need Ripe for Technological Harvest.

Authors:  Dorin Harpaz; Evgeni Eltzov; Raymond C S Seet; Robert S Marks; Alfred I Y Tok
Journal:  Biosensors (Basel)       Date:  2017-08-03

4.  Enhanced Colorimetric Signal for Accurate Signal Detection in Paper-Based Biosensors.

Authors:  Dorin Harpaz; Evgeni Eltzov; Timothy S E Ng; Robert S Marks; Alfred I Y Tok
Journal:  Diagnostics (Basel)       Date:  2020-01-07

5.  Capture-Layer Lateral Flow Immunoassay: A New Platform Validated in the Detection and Quantification of Dengue NS1.

Authors:  Tim Axelrod; Evgeni Eltzov; Robert S Marks
Journal:  ACS Omega       Date:  2020-05-04

Review 6.  Point-of-Care Diagnostics for Farm Animal Diseases: From Biosensors to Integrated Lab-on-Chip Devices.

Authors:  Georgios Manessis; Athanasios I Gelasakis; Ioannis Bossis
Journal:  Biosensors (Basel)       Date:  2022-06-26

Review 7.  Electrochemical Immuno- and Aptamer-Based Assays for Bacteria: Pros and Cons over Traditional Detection Schemes.

Authors:  Rimsha Binte Jamal; Stepan Shipovskov; Elena E Ferapontova
Journal:  Sensors (Basel)       Date:  2020-09-28       Impact factor: 3.576

  7 in total