Literature DB >> 27218046

Outcome of Radial Head Arthroplasty in Comminuted Radial Head Fractures: Short and Midterm Results.

Arash Moghaddam1, Tim Friedrich Raven2, Eike Dremel3, Stefan Studier-Fischer3, Paul Alfred Grutzner3, Bahram Biglari3.   

Abstract

BACKGROUND: Comminuted radial head fractures are often associated with secondary injuries and elbow instability.
OBJECTIVES: The aim of this retrospective study was to evaluate how well the modular metallic radial head implant EVOLVE® prosthesis restores functional range of motion (ROM) and stability of the elbow in acute care. PATIENTS AND METHODS: Eighty-five patients with comminuted radial head fractures and associated injuries received treatment with an EVOLVE® prosthesis between May 2001 and November 2009. Seventy-five patients were available for follow-up. On average, patients were followed for 41.5 months (33.0: 4.0 - 93.0). Outcome assessment was done on the basis of pain, ROM, strength, radiographic findings, and functional rating scores such as Broberg and Morrey, the Mayo elbow performance index (MEPI), and disabilities of the arm, shoulder and hand (DASH). Our study is currently the largest analysis of clinical outcome of a modular radial head replacement in the literature.
RESULTS: Overall, there were 2 (2.7%) Mason II fractures, 21 (28%) Mason III fractures, and 52 (69.3%) Mason IV fractures. Arbeitsgemeinschaft fur osteosynthesefragen (AO) classification was also determined. Of the 85 patients in our study, 75 were available for follow-up. Follow-up averaged 41.5 months (range, 4 - 93 months). Average scores for the cohort were as follows: Morrey, 85.7 (median 90.2; range 44.4 - 100); MEPI, 83.3 (85.0; 40.0 - 100); and DASH 26.1 points (22.5; 0.0 - 75.8). Mean flexion/extension in the affected joint was 125.7°/16.5°/0° in comparison to the noninjured side 138.5°/0°/1.2°. Mean pronation/supination was 70.5°/0°/67.1° in comparison to the noninjured side 83.6°/0°/84.3°. Handgrip strength of the injured compared to the non-injured arm was 78.8%. The following complications were also documented: 58 patients had periprosthetic radioluceny shown to be neither clinically significant nor relevant according to evaluated scores; 26 patients had moderate or severe periarticular ossification, and scored substantially worse according to MEPI and Morrey. Four patients required revisional surgery due to loosening of the prosthesis and chronic pain. In addition, one patient required a neurolysis of the ulnaris nerve, one developed a neobursa, and one had extensive swelling and blistering. The time interval between injury and treatment appeared to have an effect on results. Thirty-five patients were treated within the first 5 days after accident and showed better results than the 40 patients who were treated after 5 days.
CONCLUSIONS: Comminuted radial head fractures with elbow instability can be treated well with a modular radial head prosthesis, which restores stability in acute treatment. The modular radial head arthroplasty used in this study showed promising findings in short to midterm results.

Entities:  

Keywords:  Arthroplasty; Elbow Instability; Fracture; Prosthesis; Radial Head

Year:  2016        PMID: 27218046      PMCID: PMC4869438          DOI: 10.5812/traumamon.20201

Source DB:  PubMed          Journal:  Trauma Mon        ISSN: 2251-7472


1. Background

The incidence of radial head fractures constitutes about 2% to 5 % of all adult fractures (1, 2) and they are responsible for one third of all elbow injuries (3-5). When radial head fractures occur in combination with damage to the collateral ligaments of the elbow, damage to these structures results in gross instability to the elbow joint (6, 7), causing the radial head to become the primary stabilizer (8). Managing the radial head is important in restoring stability to the elbow joint and enabling early mobilization. In general, injuries to the radial head are treated accordingly: Mason I injuries are treated conservatively; Mason II injuries conservatively or if displaced with open reduction and internal fixation (ORIF) (9-11); and Mason III fractures with ORIF or radial head prosthesis (12). The resection of the radial head has received ever more criticism (9, 10) and is now only recommended for isolated fractures with no ligament injury (13-17). In any case, it is important that the joint is functionally stable following surgery (18) and early mobilization is possible to prevent elbow stiffening. A controversy exists regarding the treatment of Mason III and IV radial head fractures with some authors recommending ORIF and others the radial head prosthesis (19-26). Authors have expressed some concern over the use of radial head prostheses because of associated complications such as loss of motion, neuropathy of the ulnar nerve or posterior interosseous nerve, radiolucency, and periprosthetic osteolysis (27). In addition, there is concern that younger patients will suffer long-term consequences, which have not yet been adequately documented (23). Nevertheless, the radial head prosthesis has in many ways become increasingly more established as the treatment of choice for comminuted fractures, which often have associated ligament injuries further compromising stability (28). The first generation of radial head prostheses including Swanson’s silicon and the Vitallium prostheses had less than satisfactory results due to implant dislocations and breaks with up to 50% of implantations resulting in an aseptic prosthetic slip (2, 8, 29, 30). In addition, silicon from the implant has been associated with osteoporosis and synovitis (31). Further developments in radial head prostheses have lead to improved biomechanical properties. Modular metallic implants appear to have more free movement and there is reduced strain on the implant, which could decrease implant loosening and wear (32). In this study, we used the EVOLVE® prosthesis, which is a modular metallic system with two variable components, the head and stem joined to one another intraoperatively. Its polished surface replaces the rotating function of the radial head (8, 30) though does not appear to quite achieve complete restoration of the radial head’s function (32). Of the few modular models on the market, the EVOLVE® implant (Wright Medical Technology Inc., Arlington, Tennessee, USA) used in this study was shown to have superior valgus stability in cadaver elbows (32). It has remained the standard prosthesis for radial head fractures in our center for over 10 years, showing in our first examination good results despite periprosthetic lucency in some patients (33).

2. Objectives

This study aimed to evaluate the clinical outcomes of patients who received this implant, measured using functional rating scores according to Broberg and Morrey, the Mayo elbow performance index (MEPI), and the DASH-questionnaire. Our study is currently the largest analysis in the literature of clinical outcome of a modular metallic prosthesis for the treatment of radial head fractures.

3. Patients and Methods

3.1. Patient Characteristics

Between 2001 and 2009, 85 patients with a comminuted fracture of the radial head and associated injuries (Table 1) were treated with the EVOLVE® prosthesis. Seventy-five patients (88.2%) were available for follow-up. The average patient age was 55.9 years (mean: 55; minimum: 26 - maximum: 85), and the ratio of males to females was 35:40 (M:F). The dominant handed side was involved in 38 cases.
Table 1.

Distribution of Accompanying Injuries in Absolute and Percental Data

Accompanying InjuriesNo. (%)
Fracture of Proc.coronoideus a 38 (59.4)
Regan-Morrey type I11
Regan-Morrey type II8
Regan-Morrey type III19
Avulsion of Lig.coll.radiale 18 (28.1)
Avulsion of Lig.coll.ulnare 13 (20.3)
Capsular avulsion 9 (14.1)
Fracture of the olecranon 5 (7.8)
Fracture of the shaft of ulna 4 (6.3)
Open lesion (Tscherne I°) 5 (7.8)
Open lesion (Tscherne II°) 2 (3.1)
Fracture of capitellum humeri 1 (1.6)
Monteggia lesion 2 (3.1)
Essex-Lopresti lesion 1 (1.6)
Fracture of the scaphoid 1 (1.6)
Fracture of the thumb 1 (1.6)
Total 64 (100)

aIn 59.4% we had a fracture of Proc.coronoideus.

aIn 59.4% we had a fracture of Proc.coronoideus. Fractures were classified according to the Mason classification system modified by Johnston (34) and the AO classification (35). Demographic data such as age, occupation, mechanism of injury, localization of injury, and presence of an additional injury were recorded. Associated injuries were also recorded. There was failed internal fixation of the radial head in 7 cases (16 - 154 days), resection or partial resection of the radial head in 5 cases, persistent pain after conservative treatment in 3 cases and swelling of the elbow following late operative care in other cases.

3.2. Surgery

The placement of a radial head prosthesis was determined intraoperatively on the basis of elbow instability. Indications included a comminuted fracture of the radial head with one or more of the following: elbow dislocation, injury to the collateral ligaments, injury to the interosseous membrane (e.g. Essex Lopresti), and an olecranon fracture. Surgical treatment was performed eight days after injury on average. Thirty-five patients (46.7%) were treated within the first five days after injury, and 40 patients (53.3%) at later time points (mean 30.0; 6 - 265 days). Delayed treatment was mostly because patients came from external hospitals several days after injury. All additional injuries to the collateral ligaments or the ventral capsule were treated. Coronoid fractures were also treated in 84.2%.

3.3. Postoperative Care

Physical therapy involving passive and active assisted movement began on the first postoperative day. Patients with collateral ligament injury were instructed to avoid all varus and valgus stress for six weeks. A dorsal cast was also used to temporarily reduce elbow extension if a coronoid fracture was present. We also used motion limited hinged external fixation in three patients. All patients, unless otherwise indicated, received 75 mg of a NSAID (Voltaren®; Novarits, Basel, Switzerland) per os for 4 weeks as prophylaxis against heterotrophic ossification.

3.4. Follow-up

The average follow-up time was 41.5 months (median 33.0; minimum 4 - maximum 93). Patients were asked to complete standardized questionnaires about their daily activities and capabilities, focusing on strength, coordination, and functionality of the injured extremity. Perceived pain and overall satisfaction of medical care were also assessed. The Morrey score (3), MEPI, and DASH (36) were used to analyze results. Strength was measured for elbow flexion, extension, pronation, and supination with Primus RS™ (BTE Technologies Inc., Hanover, USA). Handgrip strength was measured with the help of a Jamar® Dynamometer.

3.5. Radiographic Assessment

The elbow was X-rayed in the anterior-posterior, lateral, and Greenspan radial head views (37) (Figure 1A and B, Figure 2A and B). If wrist injury was suspected, additional posterior-anterior wrist stress views were done bilaterally. Radiographs were interpreted by two trauma surgeons. Assessment criteria were the following: correct articulation of the joint components, position of the implant, humeroulnar arthrosis, prosthesis luxation, periprosthetic lucency (Figure 3) and heterotrophic ossification. Periarticular ossification was classified according to Brooker (38).
Figure 1.

A, Anterior-Posterior (A.p.) Radiograph of the Left Elbow at Trauma Date; B, Lateral Radiograph of the Left Elbow at Trauma Date

Figure 2.

A, Anterior-Posterior (A.P.) Radiograph of the Left Elbow 19 Months After Trauma; B, Lateral Radiograph of the Elbow 19 Months After Trauma With Minor Radiolucency Lines Around the Stem

Figure 3.

Distribution of Mean Morrey Score (pts.), Depending on Degree of Deossification Around the Stem (mm)

3.6. Statistics

Statistical analysis was done with Excel 2007 (Microsoft©), PASW 18 Statistics and AMOS 18 (SPSS© IBM).

3.7. Ethical Considerations

The Ethics Committee of the Landesärztekammer Rheinland-Pfalz approved this study (Number 837.322.07(5857)).

4. Results

4.1. Clinical Results

Of the 85 patients in our study, 75 were available for follow-up. Follow-up averaged 41.5 months (mean: 33; range, 4 - 93 months). Average scores for the cohort were as follows: Morrey, 85.7 (median 90.2; range 44.4 - 100); MEPI, 83.3 (85.0; 40.0 - 100); and DASH 26.1 points (22.5; 0.0 - 75.8). In regards to elbow range of motion (ROM), mean flexion/extension (neutral zero method) in the affected joint was 125.7°/16.5°/0° in comparison to the noninjured side 138.5°/0°/1.2°. Mean pronation/supination was 70.5°/0°/67.1° in comparison to the noninjured side, which was 83.6°/0°/84.3° (Figure 4A and B) (Table 2).
Figure 4.

A, Demonstration of ROM (Range of Motion) 24 Months After Radial Head Arthroplasty of the Left Elbow. Maximum Extension of the Elbow Joint; B, Demonstration of ROM (Range of Motion). Maximum Flexion of the Elbow Joint

Table 2.

Clinical Results Average (Median; Minimum - Maximum)

Injured ExtremityNon-injured Extremity
Elbow flexion 125.7° (130°; 90 - 150°)138.5° (140°; 120 - 150°)
Etension deficit 16.5° (15°; 0 bis 50°)−1.2° (0°; −10 - 30°)
Supination 67.1° (80°; −45 - 90°)84.3° (85°; 60 - 90°)
Pronation 70.5° (80°; 0 - 90°)83.6° (80°; 70 - 90°)
Cubitus valgus 7.7° (10°; 0 - 20°)6.9° (5°; 0 - 20°)
Handgrip strength 25.1 kg (24; 4 - 50 kg)32.4 kg (32; 10 - 56 kg)
wrist flexion 67.4° (70°; 7 - 90°)71.6° (70°; 20 - 90°)
Wrist extension 66.1° (70°; 30 - 90°)69.8° (70°; 40 - 90°)
Radial abduction 8.2° (5°; 0 - 30°)8.3° (5°; 5 - 30°)
Ulnar abduction 30.4° (30°; 10 - 50°)31.7° (30°; 15 - 50°)
Overall, there were 2 (2.7%) Mason II fractures, 21 (28%) Mason III fractures, and 52 (69.3%) Mason IV fractures. According to the AO classification, there was 1 type-21A3-fracture (1.3%), 44 type-21B2-fractures (58.7%), 2 type-21C1-fractures (2.7%), 13 type-21C2-fractures (17.3%), and 15 type-21C3-fracures (20%).

4.2. Initial Versus Delayed Treatment

Fifty-seven patients were initially treated with the radial head prosthesis; 18 patients were treated after initial osteosynthesis or resection. The 57 patients treated initially with a prosthesis showed: mean flexion/extension (neutral zero method) in the affected joint of 127.6°/15.4°/0°; and a mean pronation/supination of 72.9°/0°/70.2°. The patients had an average of 89.3 points on the Morrey score (median 92.0; range 57.2 - 100). According to the MEPI, patients had on average 88.0 points (95.0; 50.0 - 100).The DASH Score showed an average of 22.3 points (18.3; 0.0 - 75.8) (Table 3).
Table 3.

Clinical Results Initial or Later Treatment with Radial Head (RH) Prosthesis Average (Median; Minimum - Maximum)

Initial TreatmentLater Treatment
Elbow flexion 127.6° (130°; 90 - 150°)119.7° (122.5°; 90 - 140°)
Extension deficit 15.4° (10°; 0 bis 50°)20.0° (22.5°; 0° - 45°)
Supination 70.2° (80°; −45 - 90°)57.5° (60°; −30 - 90°)
Pronation 72.9° (80°; 0 - 90°)62.8° (65°; 10 - 90°)
Morrey score 89.3 (92; 57.2 - 100)75.1 (77.9; 44,4 - 99,4°)
MEPI 88.0 (95; 50 - 100)70.6 (67.5; 40 - 100)
DASH 22.3 (18.3; 0 - 75,8)37,7° (37.5°; 0 - 74,2°)

Abbreviations: MEPI, Mayo elbow performance index; DASH, disabilities of arm, shoulder and hand.

Abbreviations: MEPI, Mayo elbow performance index; DASH, disabilities of arm, shoulder and hand. The other 18 patients showed a mean flexion/extension (neutral zero method) in the affected joint of 119.7°/20.0°/0° and the mean pronation /supination was 62.9°/0°/57.5°. The patients had an average of 75.1 points according to the Morrey score (median 77.9; range of 44.4 - 99.4). Patients had an average of 70.6 points on the MEPI (67.5; 40.0 - 100). The DASH score showed an average of 37.7 points (37.5; 0.0 - 74.2) (Table 3).

4.3. Stable Versus Unstable Injuries

There appeared to be differences in Morrey, MEPI, and DASH between stable and unstable cases. Fifty-two patients with a Mason IV fracture and one patient with a Essex-Lopresti injury were evaluated as unstable and showed an average DASH of 25.85 (22.5; 0.0 - 75.83), a Mayo score of 83.30 (85.0; 40.0 - 100.0), and a Morrey score of 85.05 (88.4; 44.4 - 100.0). The patient with the an Essex-Lopresti injury showed a DASH score of 25.83 points, a Mayo score of 95 points, and a Morrey score of 90.70 points by itself. Two patients with a Mason II injury and 20 patients with a Mason III injury were evaluated as stable and showed a DASH score of 26.59 (21.67; 0.0 - 73.33), a Mayo score of 83.41 (85.0; 50.0 - 100.0), and a Morrey score of 87.12 (91.3; 63.0 - 100.0).

4.4. Wrist Flexibility, Elbow Strength, Handgrip Strength, Arm Diameter, and Cubitus Valgus

Wrist flexibility was mostly the same on the injured as on the non-injured side with some deviation; 8 patients showed mild instability in the elbow to valgus stress (lateral deviation < 5°); 3 patients showed mild instability on the contralateral side. One patient showed moderate instability (5° < lateral deviation < 10°). Mean strength of elbow flexion, extension, pronation, and supination was as follows in the injured arm compared to non-injured extremity: 71.5% for flexion, 79.1% for extension, 79.9% for pronation, and 80.0% for supination. Handgrip strength of the injured compared to the non-injured arm was 78.8%. The ratio of the arm diameter of the injured to non-injured arm was on average without pathological findings. Cubitus valgus on the affected side measured 7.7° and on the non-affected side 6.9°.

4.5. Occupational Rehabilitation

At the time of accident, 52 patients (69.3%) were employed. Time off work due to injury was on average 138 days (93, 5 - 546 days). Four patients had not yet returned to their jobs at the time of examination, 29 patients (55.8%) returned to their employment without disability, and 20 patients (38.5%) returned to work with restricted capabilities. Five patients (7.7%) needed to change their workplace. Of the 16 patients with physically strenuous employment, 3 required training for alternative employment, 5 patients could go back to work with light modifications at their working place, and 8 patients returned to work with no restrictions.

4.6. Radiological Finding

Radiographs of 73 patients in follow-up examinations revealed that in all but one case, radial head implants articulated congruently. In the one exception, prosthetic displacement was observed, but there appeared to be not associated pain nor highly impaired ROM. Fifty-eight patients (80.6%) had radiolucency lines around the stem of the prosthesis with an average width of 1 mm (Figure 3). Periarticular ossification was classified according to Brooker et al. (38). Twenty patients (27.4%) showed no periprosthetic ossification, 27 patients (52.1%) showed minimal to considerable ossification, 15 patients showed moderate, and 11 patients (15.1%) showed extensive periprosthetic ossification. Severe humeroulnar arthrosis was diagnosed in 3 patients (4.1%); 23 patients (31.5%) had considerable humeroulnar arthrosis; 21 patients (28.8%) slight; and 26 patients (35.6%) had none.

4.7. Subjective Patient Ratings

Seventy-six percent of patients reported the absence of pain or only slight pain; 24.0% reported regular and/or constant pain; 77.3% of patients reported a reduction in strength. Fifty-five patients (73.3%) rated the operative results as good or very good; 14 patients (18.7%) were satisfied with the results; and 6 (8.0%) were dissatisfied. Thirty-three patients reported no restrictions at all in their daily activities; 38 reported resting the affected extremity on a daily basis; and four reported serious restrictions in daily activities.

4.8. Complications

Eleven patients showed extensive periprosthetic ossification. In 3 cases, prosthetic revision was necessary. In one case, a new identical prosthesis was implanted because of disconnection of the head stem interface. In two cases, revisional surgery was necessary because of persistent pain and radiologic findings of loosening of the prosthesis. One of these patients required complete removal of the implant because of persisting pain. In 1 case, the implant was displaced according to radiographs performed during the study. Revisional surgery was offered to the patient; however, the patient refused due to lack of pain and good ROM. Overall, 4 cases required the removal of the radial head prosthesis. One case was already mentioned above; one case experienced a loosening after falling down on the same arm five months after the first operation; the other two cases showed periprosthetic lucency with persistent pain. No deep infection of the prosthesis or joint was noted. In addition, one patient required a neurolysis of the ulnaris nerve, one developed a neobursa, and one had extensive swelling and blistering.

5. Discussion

To our knowledge, our study is the largest analysis of clinical outcome of a modular radial head replacement in the literature. Our results show that the EVOLVE® prosthesis can restore joint integrity in fractures associated with elbow injuries and clinical outcome is better if implanted directly after injury. As in similar studies, the inclusion of a comparison group was impossible. This was because almost all patients in our center with comminuted fractures were treated with an EVOLVE® prosthesis; nevertheless, our results confirm those of previous studies and contribute greatly to current research on prosthetic devices or operative methods for radial head fractures. The older generation of radial head prosthetic devices including the silicone implants and early “mono-block” models did not fulfill the biomechanical requirements of the elbow joint, and therefore did not become established as a standard treatment option (39-41). Because osteosynthesis was not an option for treating comminuted fractures due to its failure to adequately restore stability to the elbow (2, 4, 5, 11, 42), radial head resection without a replacement arthroplasty of any sort remained the standard operative technique for comminuted fractures for many years (4, 42-44). However, resection involves a loss of stability which carries with it associated complications such as the proximal displacement of the radius and premature humeroulnar osteoarthritis (4, 11, 43-47). The newer radial head prosthetic devices, such as the EVOLVE® prosthesis in this study, were developed to improve upon previous models by maximizing radiocapetallar congruency and contact forces and allow for early mobilization (48). Indeed, our functional and radiological results for the modular prosthesis showed a good surgical outcome using a modular metallic prosthesis. Average scores for our cohort were as follows: Morrey, 85.7 (median 90.2; range 44.4 - 100); MEPI, 83.3 (85.0; 40.0 - 100); and DASH 26.1 points (22.5; 0.0 - 75.8). This is despite having an especially high number of associated injuries; we diagnosed additional injuries to the elbow in 85.3% of case, which is significantly higher than the 30% - 68% reported in the literature (49, 50). The combination of these injuries with radial head resection without an implant would probably have led to instability of the elbow and late complications (3, 6, 32, 42). Other authors have also described good results in line with our findings. Grewal et al. (8) investigated the use of a modular metallic prosthesis in the treatment of 26 patients with a radial head fracture of the arm. This was the first study documenting short-term results. They reported an average MEPI of 82 and DASH of 24.4 (8), which is very close to our findings. Only two patients in the Grewal et al. (8) study were reported as having poor results based on MEPI. Both had a terrible-triad injury. Other authors have also documented poor results for terrible triad injuries (8, 21, 41, 51, 52). Though we recorded no results for patients with a terrible triad, one patient in our study had an Essex-Lopresti injury and results were surprisingly good; the Morrey score was 90.7, and MEPI was 95.0. In the largest investigation of a bipolar prosthesis, Zunkiewicz et al. reported a slightly higher MEPI of 92.1 and a lower DASH of 13.8 (48). Authors reported good results with a bipolar prosthesis with a telescoping stem despite a patient pool with many associated injuries. Measurements of elbow flexion/extension and pronation/supination in our patient pool were similar to those reported by Zunkiewicz et al. (48) Our mean flexion/extension (neutral zero method) of the affected joint was 125.7°/16.5°/0° compared to an flexion/extension arc of 126° in an earlier study. Mean pronation/supination was 70.5°/0°/67.1° compared to 69°/0°/74°. In addition, similar to our study, they found that results were better in patients with initial vs. later reconstructive treatment. Concerning radiological findings, Grewal et al. observed substantially less heterotopic ossification in their cohort with only six of 26 patients showing radiological signs and only one patient showing severe ossification (8). Our data showed that 27 patients had minimal to considerable ossification, 15 patients moderate, and 11 patients showed extensive ossification. A significant decline in the Morrey score (P = 0.036) was correlated with an increase in heterotopic ossification. A correlation between periprosthetic radiolucency and outcome was not determined in our study and has not been observed by other authors (8, 49, 53, 54). In fact, 58 patients (80.6%) were noted to have a line of deossification around the prosthesis stem in our cohort and patients showing periprosthetic deossification measuring 0.5 - 1 mm had slightly better results than those having no deossification around the stem (Figure 3). Perhaps one explanation for the extensive periprosthetic radiolucency in this study is that the polished surface of the material is not suitable for growth of bone into the prosthesis. Causes of periprosthetic radiolucency, however, are yet to be identified and we assume that these radiological findings are signs of evasive movement of the radial head prosthesis in the proximal radius to prevent transfer of high pressure levels to the capitulum humeri as stated by Harrington et al. (55). Perhaps an explanation for the good results in our study is that the modular metallic prosthesis functions as an exact fit with the humeroulnar joint, so that neither understuffing nor overstuffing occurs. Understuffing can lead to excessive laxity and overstuffing can cause reposition difficulties such as hyperpressure on the capitulum humeri with a range of tolerance of ± 2 mm (56). In our study we measured the radial head intraoperatively and varied the prosthesis height accordingly. Radiographs confirmed joint congruencies and overstuffing was avoided. The implantation of a modular prosthesis in combination with ligament reconstruction and early postoperative rehabilitation allows one to avoid the biomechanical disadvantages associated with radial head excision. In conducting this study, we came to the conclusion that the current classification of fractures based on Mason and AO is neither helpful in determining proper treatment nor in judging prognosis for high grade radial head fractures. This is because the role of ligament injury of the elbow is not taken into account. Another classification system is needed. We also believe that long-term results for assessing the relevance of deossification around the stem found in some patients are needed. Overall, we found that comminuted radial head fractures with elbow instability can be treated well with a modular metallic radial head prosthesis, which restores stability and integrity of the joint. The primary therapy with the prosthesis outclasses the secondary treatment.
  52 in total

1.  [Comminuted radial head fractures. Initial experiences with a Judet radial head prosthesis].

Authors:  F Holmenschlager; J P Halm; S Piatek; S Schubert; S Winckler
Journal:  Unfallchirurg       Date:  2002-04       Impact factor: 1.000

2.  [Prosthesis after comminuted radial head fractures : midterm results].

Authors:  A Moghaddam; A Lennert; S Studier-Fischer; A Wentzensen; G Zimmermann
Journal:  Unfallchirurg       Date:  2008-12       Impact factor: 1.000

Review 3.  Radial head fracture: open reduction-internal fixation or prosthetic replacement.

Authors:  David Ring
Journal:  J Shoulder Elbow Surg       Date:  2011-03       Impact factor: 3.019

Review 4.  Radial head fractures: effectiveness of conservative treatment versus surgical intervention. A systematic review.

Authors:  P A A Struijs; G Smit; E Ph Steller
Journal:  Arch Orthop Trauma Surg       Date:  2006-10-26       Impact factor: 3.067

5.  Silastic prosthetic replacement for the radial head.

Authors:  B F Morrey; L Askew; E Y Chao
Journal:  J Bone Joint Surg Am       Date:  1981-03       Impact factor: 5.284

Review 6.  [Surgical differential therapy of fracture of the radius head].

Authors:  A Betz
Journal:  Orthopade       Date:  1988-06       Impact factor: 1.087

7.  Function after early radial head resection for fracture: a retrospective evaluation of 15 patients followed for 3-18 years.

Authors:  M Ikeda; Y Oka
Journal:  Acta Orthop Scand       Date:  2000-04

8.  [Replacement of the comminuted radial head fracture by a bipolar radial head prosthesis].

Authors:  M C Müller; C Burger; D C Wirtz; O Weber
Journal:  Oper Orthop Traumatol       Date:  2011-02       Impact factor: 1.154

9.  Treatment of radial head and neck fractures: in favor of anatomical reconstruction.

Authors:  K J Burkhart; K Wegmann; J Dargel; C Ries; L P Mueller
Journal:  Eur J Trauma Emerg Surg       Date:  2012-09-13       Impact factor: 3.693

10.  Radial head arthroplasty with an uncemented modular metallic radial head prosthesis: short- and mid-term results.

Authors:  M Muhm; R de Castro; H Winkler
Journal:  Eur J Trauma Emerg Surg       Date:  2010-09-23       Impact factor: 3.693

View more
  9 in total

1.  The Radial Floating Cup radial head prosthesis to treat radial head fractures: functional and radiographic results after more than 12 years of mean follow-up.

Authors:  Baptiste Montbarbon; Hoel Letissier; Frédéric Dubrana; Dominique Le Nen; Rémi Di Francia
Journal:  Arch Orthop Trauma Surg       Date:  2020-07-25       Impact factor: 3.067

Review 2.  Radial head fractures.

Authors:  R P van Riet; Mpj van den Bekerom; A Van Tongel; C Spross; R Barco; A C Watts
Journal:  Shoulder Elbow       Date:  2019-09-25

3.  Clinical long-term results of radial head arthroplasty in comminuted radial head fractures.

Authors:  T F Raven; A Moghaddam; S Studier-Fischer; P A Grützner; B Biglari
Journal:  Musculoskelet Surg       Date:  2022-03-30

4.  Evaluation of MoPyC-prosthesis implantation and the use of angular stable plates in the treatment of comminuted radial head fractures.

Authors:  T F Raven; M Schönewald; J Doll; L Banken; G Schmidmaier; A Moghaddam
Journal:  J Orthop       Date:  2019-03-25

5.  Evaluation of MoPyC-prosthesis implantation and the use of angular stable plates in the treatment of comminuted radial head fractures.

Authors:  T F Raven; M Schönewald; J Doll; L Banken; G Schmidmaier; A Moghaddam
Journal:  J Orthop       Date:  2019-03-21

Review 6.  Midterm outcomes of 146 EVOLVE Proline modular radial head prostheses: a systematic review.

Authors:  Pierre Laumonerie; Maroun Raad; Meagan E Tibbo; Panagiotis Kerezoudis; Nicolas Bonnevialle; Pierre Mansat
Journal:  Shoulder Elbow       Date:  2019-05-19

Review 7.  Why does radial head arthroplasty fail today? A systematic review of recent literature.

Authors:  Jetske Viveen; Izaak F Kodde; Andras Heijink; Koen L M Koenraadt; Michel P J van den Bekerom; Denise Eygendaal
Journal:  EFORT Open Rev       Date:  2020-01-28

8.  Radiographic Predictors for Short-term Functional Outcome after Radial Head Arthroplasty in Patients with Persistent Symptoms after Treatment for Radial Head.

Authors:  Femke M A P Claessen; Rens Bexkens; I F Kodde; Job N Doornberg; Michel P J V D Bekerom; Denise Eygendaal
Journal:  Arch Bone Jt Surg       Date:  2020-01

9.  Functional outcomes evaluation after radial head arthoplasty in DR. Syaiful Anwar General Hospital: Case series.

Authors:  Agung Riyanto Budi Santoso; Thomas Erwin Christian Junus Huwae; Dedde Aditya Rachman; Marvin Anthony Putera
Journal:  Int J Surg Case Rep       Date:  2020-05-08
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.