Literature DB >> 27216668

Disposable sensor for electrochemical determination of chloride ions.

Julia Bujes-Garrido1, M Julia Arcos-Martínez2.   

Abstract

This work describes the development of a new, simple and inexpensive method for the determination of chloride ions, by using voltammetric disposable sensors. The sensor includes three screen printed electrodes: a working, an auxiliary (both carbon based paste electrodes), and a pseudo-reference Ag/AgCl paste based electrode. Since the presence of chloride ions in the solution modifies the equilibrium potential of Ag/AgCl electrode, the concentration of this analyte has been determined through the systematic shift of the voltammetric peak potential of a control species such as potassium ferricyanide, potassium ferrocyanide or ferrocenemethanol. These control species can be used in solution or mixed into the carbon paste of the working screen printed electrode. In order to characterize the developed methods, reproducibility, repeatability and detection limit of the sensors were calculated in each case. Reproducibility values below 3% (n=5) were obtained. When ferrocenemethanol was used as control species, the lowest quantity of chloride ions detected was 10.0mM. A comprehensive study of interfering ions was also carried out. These sensors were successfully applied to determine the chloride content in sea water and in a commercial saline solution sample.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Chloride ion; Differential pulse voltammetry; Electrochemical sensor; Screen-printed electrode; Sea water

Year:  2016        PMID: 27216668     DOI: 10.1016/j.talanta.2016.04.038

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  4 in total

1.  Colorimetric sensing of chloride in sweat based on fluorescence wavelength shift via halide exchange of CsPbBr3 perovskite nanocrystals.

Authors:  Feiming Li; Yufeng Feng; Yipeng Huang; Qiuhong Yao; Guihua Huang; Yimeng Zhu; Xi Chen
Journal:  Mikrochim Acta       Date:  2021-01-02       Impact factor: 5.833

2.  Silver-manganese nanocomposite modified screen-printed carbon electrode in the fabrication of an electrochemical, disposable biosensor strip for cystic fibrosis.

Authors:  P Arun Kumar; Aarathi Pradeep; Bipin Kumar G Nair; T G Satheesh Babu; Punathil Vasu Suneesh
Journal:  Mikrochim Acta       Date:  2022-08-11       Impact factor: 6.408

3.  Ion-triggered calcium hydroxide microcapsules for enhanced corrosion resistance of steel bars.

Authors:  Zi Liang; Qian Wang; Biqin Dong; Bingyin Jiang; Feng Xing
Journal:  RSC Adv       Date:  2018-11-27       Impact factor: 3.361

Review 4.  Unlocking All-Solid Ion Selective Electrodes: Prospects in Crop Detection.

Authors:  Jiawei Zhai; Bin Luo; Aixue Li; Hongtu Dong; Xiaotong Jin; Xiaodong Wang
Journal:  Sensors (Basel)       Date:  2022-07-25       Impact factor: 3.847

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.