| Literature DB >> 27211944 |
William Feng1, Michael Coady2.
Abstract
We report our experience with emergent treatment of ventricular rupture following a mitral valve replacement in a 90 year-old male. The repair was performed using a Tachosil patch (Baxter Health Care Corporation, Westlake Village, California), a fibrin sealant coated on an equine collagen sponge, and BioGlue (Cryolife, Kenneson, GA) and bovine pericardium (Edwards Lifesciences, Irvine, CA). Aside from early ventricular dysfunction requiring a low-dose dopamine infusion, this patient's recovery was uneventful. Follow-up echocardiograms demonstrated no gross anatomic abnormality at the repair site, and steady improvement in his ventricular function.Entities:
Mesh:
Substances:
Year: 2016 PMID: 27211944 DOI: 10.1016/j.athoracsur.2015.07.066