Literature DB >> 27211783

Biaxial tensile tests of the porcine ascending aorta.

Valérie Deplano1, Mourad Boufi2, Olivier Boiron3, Carine Guivier-Curien3, Yves Alimi4, Eric Bertrand3.   

Abstract

One of the aims of this work is to develop an original custom built biaxial set-up to assess mechanical behavior of soft tissues. Stretch controlled biaxial tensile tests are performed and stereoscopic digital image correlation (SDIC) is implemented to measure the 3D components of the generated displacements. Using this experimental device, the main goal is to investigate the mechanical behavior of porcine ascending aorta in the more general context of human ascending aorta pathologies. The results highlight that (i) SDIC arrangement allows accurate assessment of displacements and so stress strain curves, (ii) porcine ascending aorta has a nearly linear and anisotropic mechanical behavior until 30% of strain, (iii) porcine ascending aorta is stiffer in the circumferential direction than in the longitudinal one, (iv) the material coefficient representing the interaction between the two loading directions is thickness dependent, (v) taking into account the variability of the samples the stress values are independent of the stretch rate in the range of values from 10(-3) to 10(-1)s(-1) and finally, (vi) unlike other segments of the aorta, 4-month-old pigs ascending aorta is definitely not a relevant model to investigate the mechanical behavior of the human ascending aorta.
Copyright © 2016 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Biaxial tensile test; Porcine ascending aorta; Stereoscopic Digital Image Correlation; Stretch rate

Mesh:

Year:  2016        PMID: 27211783     DOI: 10.1016/j.jbiomech.2016.05.005

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  2 in total

1.  Biaxial testing system for characterization of mechanical and rupture properties of small samples.

Authors:  Andrea Corti; Tariq Shameen; Shivang Sharma; Annalisa De Paolis; Luis Cardoso
Journal:  HardwareX       Date:  2022-06-28

2.  Changes in aortic pulse wave velocity of four thoracic aortic stent grafts in an ex vivo porcine model.

Authors:  Hector W L de Beaufort; Margherita Coda; Michele Conti; Theodorus M J van Bakel; Foeke J H Nauta; Ettore Lanzarone; Frans L Moll; Joost A van Herwaarden; Ferdinando Auricchio; Santi Trimarchi
Journal:  PLoS One       Date:  2017-10-05       Impact factor: 3.240

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.