Literature DB >> 2721053

The use of somatosensory evoked potential during revision or reoperation for total hip arthroplasty.

O A Nercessian1, E G Gonzalez, F E Stinchfield.   

Abstract

Somatosensory evoked potential (SSEP) was used to continuously monitor the sciatic nerve intraoperatively during revision or reoperation for total hip arthroplasty. Of 25 cases monitored, eight patients (32%) exhibited 12 instances of SSEP deterioration, indicating neurologic compromise. These neurologic problems were due to retraction in seven cases and limb positioning in five. No postoperative neurologic deficits were noted in this group. Two of 35 patients (5.7%) not monitored had postoperative neurologic deficits. SSEP monitoring is a useful method for minimizing the intraoperative risks of clinical neurologic deficits during revisions or difficult reoperations.

Entities:  

Mesh:

Year:  1989        PMID: 2721053

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  7 in total

1.  Intraoperative monitoring using somatosensory evoked potentials. A position statement by the American Society of Neurophysiological Monitoring.

Authors:  J Richard Toleikis
Journal:  J Clin Monit Comput       Date:  2005-06       Impact factor: 2.502

Review 2.  Nerve injuries associated with total hip arthroplasty.

Authors:  Rohit Hasija; John J Kelly; Neil V Shah; Jared M Newman; Jimmy J Chan; Jonathan Robinson; Aditya V Maheshwari
Journal:  J Clin Orthop Trauma       Date:  2017-10-28

3.  [Avoidance, diagnostics and therapy of nerve lesions after total hip arthroplasty].

Authors:  S Kirschner; J Goronzy; A Storch; K-P Günther; A Hartmann
Journal:  Orthopade       Date:  2011-06       Impact factor: 1.087

4.  The gluteal sling: an anatomical study.

Authors:  C Isik; N Apaydin; H I Acar; A Zahar; M Bozkurt
Journal:  Surg Radiol Anat       Date:  2013-11-09       Impact factor: 1.246

5.  Somatosensory evoked potentials are not a sensitive indicator of potential positioning injury in the prone patient.

Authors:  N A Lorenzini; K A Poterack
Journal:  J Clin Monit       Date:  1996-03

6.  Acute effects of hip and knee positions on motor-evoked potentials of the sciatic nerve in total hip arthroplasty.

Authors:  Kei Shiramizu; Masatoshi Naito; Yuichiro Akiyoshi; Tetsu Yamaguchi
Journal:  Int Orthop       Date:  2003-03-26       Impact factor: 3.075

7.  Leg lengthening of more than 5 cm is a risk factor for sciatic nerve injury after total hip arthroplasty for adult hip dislocation.

Authors:  Yoshitoshi Higuchi; Yukiharu Hasegawa; Naoki Ishiguro
Journal:  Nagoya J Med Sci       Date:  2015-08       Impact factor: 1.131

  7 in total