Literature DB >> 2720981

Unreliable visual estimation of the incidence and amount of turbidity, hemolysis, and icterus in serum from hospitalized patients.

M R Glick1, K W Ryder, S J Glick, J R Woods.   

Abstract

We examined the frequency of occurrence for turbidity, hemolysis, or icterus in 2599 serum samples submitted for chemistry testing in an acute-care general hospital. Each specimen was compared visually with full-color photographs of adulterated serum, and designated as either "0" (containing no interferent), or trace, 1+, 2+, 3+, 4+, or 5+. Visible interferents (1+ or greater) were thought to be present in 838 (31%) of the specimens (icterus, 525; hemolysis, 244; lipemia, 69). To assess the accuracy of such visual grading, we determined the concentration of triglycerides, hemoglobin, or bilirubin in the specimens considered to be contaminated. There was little agreement between the actual concentration of each interferent and the assigned grade of turbidity, hemolysis, or icterus, confirming the unreliability of human visual estimation of these potentially interfering substances.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2720981

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  5 in total

1.  Removing Lipemia in Serum/Plasma Samples: A Multicenter Study.

Authors:  María José Castro-Castro; Beatriz Candás-Estébanez; Margarita Esteban-Salán; Pilar Calmarza; Teresa Arrobas-Velilla; Carlos Romero-Román; Miguel Pocoví-Mieras; José Ángel Aguilar-Doreste
Journal:  Ann Lab Med       Date:  2018-11       Impact factor: 3.464

Review 2.  Hemolyzed Specimens: Major Challenge for Identifying and Rejecting Specimens in Clinical Laboratories.

Authors:  Wan Norlina Wan Azman; Julia Omar; Tan Say Koon; Tuan Salwani Tuan Ismail
Journal:  Oman Med J       Date:  2019-03

3.  Lipemia Interferences in Biochemical Tests, Investigating the Efficacy of Different Removal Methods in comparison with Ultracentrifugation as the Gold Standard.

Authors:  Neda Soleimani; Sahand Mohammadzadeh; Fateme Asadian
Journal:  J Anal Methods Chem       Date:  2020-02-12       Impact factor: 2.193

Review 4.  Lipemia: causes, interference mechanisms, detection and management.

Authors:  Nora Nikolac
Journal:  Biochem Med (Zagreb)       Date:  2014-02-15       Impact factor: 2.313

5.  The incidence rate and influence factors of hemolysis, lipemia, icterus in fasting serum biochemistry specimens.

Authors:  Gang Tian; Yu Wu; Xinrui Jin; Zhangrui Zeng; Xiujuan Gu; Tao Li; Xiu Chen; Guangrong Li; Jinbo Liu
Journal:  PLoS One       Date:  2022-01-19       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.