Literature DB >> 27209004

Studies of DNA Aptamer OliGreen and PicoGreen Fluorescence Interactions in Buffer and Serum.

John G Bruno1, Jeffrey C Sivils2.   

Abstract

Spectrofluorometric and emission peak titration and timed studies of OliGreen (OG) and PicoGreen (PG) were conducted in Tris EDTA (TE) buffer, pooled rat and fetal bovine serum with two different aptamers of 72 and 192 bases in length to determine if OG or PG were suitable for aptamer pharmacokinetic (PK) studies in sera. Results indicated that OG and PG detected the single-stranded (ss) and double-stranded (ds) stem-loop structures of the two aptamers quite well in TE with reliable standard curves having exponential character (or several linear detection regions) up to 1 μg/ml of aptamer DNA with detection limits of ~1 ng/ml. The intensity of OG and PG staining appeared to correlate with the number and percentage of ss and ds bases in each aptamer. OG and PG fluorescence in pooled rat serum or fetal bovine serum (FBS) did not titer as a function of DNA aptamer concentration from 1 μg/ml to 1 ng/ml. This lack of OG or PG aptamer assays in serum is contrary to most published reports of OG or PG assays for ss antisense oligonucleotides, ds PCR amplicons or other types of DNA in serum or plasma. Further studies suggested that the lack of OG and PG assay titration in serum might not be entirely due to aptamer degradation from nucleases in serum since the fluorescence signals in serum appeared relatively stable over time from 30 min to 4 hours. A hypothesis is presented which attributes the inability of OG or PG to assay aptamers in serum to a combination of high blue-green autofluorescence in serum with possible serum nuclease degradation of aptamers over time and the changing aptamer to serum protein ratio coupled to nonspecific binding of serum proteins to aptamers thereby possibly changing aptamer conformations as a function of aptamer concentration during titration experiments.

Entities:  

Keywords:  Aptamer; Double-stranded; Electrophoresis; OliGreen; PicoGreen; Serum; Single-stranded

Mesh:

Substances:

Year:  2016        PMID: 27209004      PMCID: PMC4958561          DOI: 10.1007/s10895-016-1840-1

Source DB:  PubMed          Journal:  J Fluoresc        ISSN: 1053-0509            Impact factor:   2.217


  26 in total

1.  Quantitative determination of short single-stranded oligonucleotides from blood plasma using capillary electrophoresis with laser-induced fluorescence.

Authors:  L Reyderman; S Stavchansky
Journal:  Anal Chem       Date:  1997-08-15       Impact factor: 6.986

2.  A methodology for quantitation and characterization of oligonucleotides in albumin microspheres.

Authors:  Mohammad N Uddin; Duc P Do; S Balakrishna Pai; Sanjay Gayakwad; Carl W Oettinger; Martin J D'Souza
Journal:  Analyst       Date:  2009-04-17       Impact factor: 4.616

3.  Sensitive fluorescence assay of anthrax protective antigen with two new DNA aptamers and their binding properties.

Authors:  Byul Nim Oh; Sungeun Lee; Hye-Yeon Park; Jin-Ook Baeg; Moon-Young Yoon; Jinheung Kim
Journal:  Analyst       Date:  2011-07-11       Impact factor: 4.616

4.  PicoGreen quantitation of DNA: effective evaluation of samples pre- or post-PCR.

Authors:  S J Ahn; J Costa; J R Emanuel
Journal:  Nucleic Acids Res       Date:  1996-07-01       Impact factor: 16.971

5.  Characterization of PicoGreen reagent and development of a fluorescence-based solution assay for double-stranded DNA quantitation.

Authors:  V L Singer; L J Jones; S T Yue; R P Haugland
Journal:  Anal Biochem       Date:  1997-07-01       Impact factor: 3.365

6.  Highly sensitive fluorescent detection of small molecules, ions, and proteins using a universal label-free aptasensor.

Authors:  Zhenzhen Lv; Jinchuan Liu; Yu Zhou; Zheng Guan; Shuming Yang; Cheng Li; Ailiang Chen
Journal:  Chem Commun (Camb)       Date:  2013-05-13       Impact factor: 6.222

7.  Quantitative analysis of cell-free DNA in the plasma of gastric cancer patients.

Authors:  Jong-Lyul Park; Hyun Ja Kim; Bo Youl Choi; Han-Chul Lee; Hay-Ran Jang; Kyu Sang Song; Seung-Moo Noh; Seon-Young Kim; Dong Soo Han; Yong Sung Kim
Journal:  Oncol Lett       Date:  2012-02-03       Impact factor: 2.967

8.  Serum inverts and improves the fluorescence response of an aptamer beacon to various vitamin D analytes.

Authors:  John G Bruno; Maria P Carrillo; Taylor Phillips; Allison Edge
Journal:  Luminescence       Date:  2011-06-28       Impact factor: 2.464

9.  Pharmacokinetics and biodistribution of novel aptamer compositions.

Authors:  Judith M Healy; Scott D Lewis; Markus Kurz; Ryan M Boomer; Kristin M Thompson; Charles Wilson; Thomas G McCauley
Journal:  Pharm Res       Date:  2004-12       Impact factor: 4.200

10.  A simple and sensitive approach for ochratoxin A detection using a label-free fluorescent aptasensor.

Authors:  Zhenzhen Lv; Ailiang Chen; Jinchuan Liu; Zheng Guan; Yu Zhou; Siyuan Xu; Shuming Yang; Cheng Li
Journal:  PLoS One       Date:  2014-01-21       Impact factor: 3.240

View more
  2 in total

Review 1.  Recent Progress and Opportunities for Nucleic Acid Aptamers.

Authors:  Jonghoe Byun
Journal:  Life (Basel)       Date:  2021-02-28

2.  Self-assembly and label-free fluorescent aptasensor based on deoxyribonucleic acid intercalated dyes for detecting lactoferrin in milk powder.

Authors:  Jiahui Liu; Tengfei Li; Hongwei Qin; Linsen Li; Mengmeng Yan; Chao Zhu; Feng Qu; A M Abd El-Aty
Journal:  Front Nutr       Date:  2022-09-15
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.