Literature DB >> 2720867

Haemodynamic effects of atropine during halothane or isoflurane anaesthesia in infants and small children.

D J Murray1, R B Forbes, J B Dillman, L T Mahoney, D L Dull.   

Abstract

In this study, two-dimensional and pulsed Doppler echocardiography were used to measure cardiovascular changes before and after IV atropine in 31 infants and small children during halothane (n = 15) or isoflurane (n = 16) anaesthesia. Prior to induction of anaesthesia heart rate (HR), mean blood pressure (MBP), and two-dimensional echocardiographic dimensions of the left ventricle and pulmonary artery blood flow velocity were measured by pulsed Doppler echocardiography. Cardiovascular measurements were repeated while anaesthesia was maintained at 1.5 MAC halothane (n = 15) or isoflurane (n = 16). Atropine 0.02 mg.kg-1 IV was then administered and two minutes later, a third set of cardiovascular data was obtained. Heart rate decreased during halothane anaesthesia but did not change significantly during isoflurane anaesthesia. Mean blood pressure, cardiac output (CO) and stroke volume (SV) decreased similarly during 1.5 MAC halothane or isoflurane anaesthesia. Ejection fraction (EF) decreased and left ventricular end-diastolic volume (LVEDV) increased significantly in both groups, but decreases in EF (32 +/- 5 per cent vs 18 +/- 5 per cent) and increases in LVEDV (18 +/- 7 per cent vs 7 +/- 5 per cent) were significantly greater during halothane than during isoflurane anaesthesia. Following atropine, HR increased more in the patients maintained with halothane (31 +/- 6 per cent), than during isoflurane anaesthesia (18 +/- 5 per cent). Atropine increased CO in both groups of patients, but SV and EF remained unchanged. When compared with awake values, HR increased similarly and significantly (18 +/- 4 per cent) following atropine in both groups, and CO returned to control levels.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2720867     DOI: 10.1007/BF03010768

Source DB:  PubMed          Journal:  Can J Anaesth        ISSN: 0832-610X            Impact factor:   5.063


  22 in total

1.  The relationship between age and halothane requirement in man.

Authors:  G A Gregory; E I Eger; E S Munson
Journal:  Anesthesiology       Date:  1969-05       Impact factor: 7.892

Review 2.  Advances in noninvasive cardiovascular imaging: implications for the anesthesiologist.

Authors:  M K Cahalan; L Litt; E H Botvinick; N B Schiller
Journal:  Anesthesiology       Date:  1987-03       Impact factor: 7.892

3.  Echocardiographic evaluation of cardiac performance.

Authors:  T G DiSessa; W F Friedman
Journal:  Cardiol Clin       Date:  1983-08       Impact factor: 2.213

4.  Ventricular function in children during halothane anesthesia: an echocardiographic evaluation.

Authors:  P G Barash; S Glanz; J D Katz; K Taunt; N S Talner
Journal:  Anesthesiology       Date:  1978-08       Impact factor: 7.892

5.  Cardiovascular depression during halothane anesthesia in infants: study of three induction techniques.

Authors:  R H Friesen; J L Lichtor
Journal:  Anesth Analg       Date:  1982-01       Impact factor: 5.108

6.  Nitrous oxide: cardiovascular effects in infants and small children during halothane and isoflurane anesthesia.

Authors:  D Murray; R Forbes; K Murphy; L Mahoney
Journal:  Anesth Analg       Date:  1988-11       Impact factor: 5.108

7.  Hemodynamic effects of isoflurane in the newborn piglet: comparison with halothane.

Authors:  R A Schieber; A Namnoum; A Sugden; G K Shiu; R A Orr; D R Cook
Journal:  Anesth Analg       Date:  1986-06       Impact factor: 5.108

8.  The hemodynamic and cardiovascular effects of isoflurane and halothane anesthesia in children.

Authors:  W J Wolf; M B Neal; M D Peterson
Journal:  Anesthesiology       Date:  1986-03       Impact factor: 7.892

9.  The newborn transitional circulation: a two-dimensional Doppler echocardiographic study.

Authors:  L T Mahoney; K G Coryell; R M Lauer
Journal:  J Am Coll Cardiol       Date:  1985-09       Impact factor: 24.094

10.  Accuracy of expiratory carbon dioxide measurements using the coaxial and circle breathing circuits in small subjects.

Authors:  R A Schieber; A Namnoum; A Sugden; A L Saville; R A Orr
Journal:  J Clin Monit       Date:  1985-07
View more
  1 in total

1.  Hemodynamic responses during induction of anesthesia with halothane-nitrous oxide in children with or without atropine premedication.

Authors:  S Kawana; A Namiki; Y Morita; H Watanabe; H Tsuchida
Journal:  J Anesth       Date:  1992-01       Impact factor: 2.078

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.