Literature DB >> 27206070

Application of a Shape-Memory Alloy Concentrator in Displaced Patella Fractures: Technique and Long-Term Results.

Yuntong Zhang1, Panfeng Wang1, Yan Xia1, Panyu Zhou1, Yang Xie2, Shuogui Xu1, Chuncai Zhang1.   

Abstract

Operative treatment is usually recommended in displaced patella fractures. Several techniques have been advocated for internal fixation of patella fractures. Despite the relatively good clinical outcomes that have been demonstrated in many studies, postoperative morbidities such as fixation failure, nonunion, infection, and knee stiffness are not uncommon. We present a new alternative treatment technique for displaced patellar fractures. Between April 1995 and May 2005, we used the Nitinol Patella Concentrator (NTPC) to treat 156 consecutive patients with displaced patellar fractures. Injuries arose from vehicular accidents in 56 (35.9%) cases, direct falls onto the knee in 85 (54.5%) cases, and sports injuries in 15 (9.6%) cases. The mean patient age was 46.3 years (range, 25-77 years). Clinical assessments were made using the Böstman knee score and the MOS SF-36 questionnaire (Medical Outcomes Study 36-item short-form health survey), which were both recorded at the final follow-up visit. The mean follow-up was 7.3 years (range, 6-17 years). At the final follow-up, the Böstman knee scores were excellent in 88 cases (28-30), good in 55 (20-27), and unsatisfactory in 13 (<20). According to the MOS SF-36 evaluation, the average score was 84.5 (range, 62-91). Treatment of patellar fracture with the NTPC not only may serve as an effective and rigid fixation method in multifragmented displaced and inferior pole fractures, but also may provide continuous concentrative compression during the osseous healing process. Thus, use of the NTPC may help restore the functional integrity of the extensor mechanism and permit early rehabilitation with a lower incidence of postoperative complications. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27206070     DOI: 10.1055/s-0036-1584187

Source DB:  PubMed          Journal:  J Knee Surg        ISSN: 1538-8506            Impact factor:   2.757


  5 in total

1.  Application of an arched, Ni-Ti shape-memory connector in repairing distal tibiofibular syndesmosis ligament injury.

Authors:  Jinbo Zhao; Yuntong Zhang; Yan Xia; Xuhui Wang; Shuogui Xu; Yang Xie
Journal:  BMC Musculoskelet Disord       Date:  2022-05-19       Impact factor: 2.562

2.  Combination of mini locking plate and nitinol arched shape-memory connector for purely lateral malleolus fractures: technique and clinical results.

Authors:  Demeng Xia; Yuntong Zhang; Tianle Ou; Yang Wang; Zichen Hao; Panyu Zhou; Shuogui Xu
Journal:  Ann Transl Med       Date:  2020-12

3.  The clinical outcome of the reduction of the patellar inferior pole fracture with wire cerclage through a generated bone hole, in combination with patellar concentrator: a retrospective comparative study.

Authors:  Rong Chen; Hong Cao; Zhibo Sun; Liangbo Jiang; Xiangwei Li; Lin Zhao; Xinghui Liu
Journal:  J Orthop Surg Res       Date:  2022-02-21       Impact factor: 2.359

4.  Treatment of inferior pole fracture of the patella with tension-free external immobilization.

Authors:  Shaoquan Pu; Yanling Chen; Jinlong Liang; Yongqing Xu; Yonghui Zhao
Journal:  BMC Surg       Date:  2022-09-12       Impact factor: 2.030

5.  Clinical outcomes of Ti-Ni shape-memory patella concentrator combined with cannulated compression screws in the treatment of C2 and C3 patella fracture: a retrospective study of 54 cases.

Authors:  Chen Yao; Jie Sun; Jiancheng Wu; Zhenyu Zhou; Fan Liu; Ran Tao; Yafeng Zhang
Journal:  BMC Musculoskelet Disord       Date:  2020-07-31       Impact factor: 2.362

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.