Literature DB >> 27203463

An immunochromatographic biosensor combined with a water-swellable polymer for automatic signal generation or amplification.

Kahee Kim1, Hyou-Arm Joung1, Gyeo-Re Han1, Min-Gon Kim2.   

Abstract

An immunochromatographic assay (ICA) strip is one of the most widely used platforms in the field of point-of-care biosensors for the detection of various analytes in a simple, fast, and inexpensive manner. Currently, several approaches for sequential reactions in ICA platforms have improved their usability, sensitivity, and versatility. In this study, a new, simple, and low-cost approach using automatic sequential-reaction ICA strip is described. The automatic switching of a reagent pad from separation to attachment to the test membrane was achieved using a water-swellable polymer. The reagent pad was dried with an enzyme substrate for signal generation or with signal-enhancing materials. The strip design and system operation were confirmed by the characterization of the raw materials and flow analysis. We demonstrated the operation of the proposed sensor by using various chemical reaction-based assays, including metal-ion amplification, enzyme-colorimetric reaction, and enzyme-catalyzed chemiluminescence. Furthermore, by employing C-reactive protein as a model, we successfully demonstrated that the new water-swellable polymer-based ICA sensor can be utilized to detect biologically relevant analytes in human serum.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Automatic sequential reaction; C-reactive protein; Chemiluminescence; Lateral flow immunoassay; Signal amplification; Water-swellable polymer

Mesh:

Substances:

Year:  2016        PMID: 27203463     DOI: 10.1016/j.bios.2016.04.096

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  5 in total

Review 1.  Lateral flow biosensors based on the use of micro- and nanomaterials: a review on recent developments.

Authors:  Yan Huang; Tailin Xu; Wenqian Wang; Yongqiang Wen; Kun Li; Lisheng Qian; Xueji Zhang; Guodong Liu
Journal:  Mikrochim Acta       Date:  2019-12-18       Impact factor: 5.833

2.  Modification of a nitrocellulose membrane with nanofibers for sensitivity enhancement in lateral flow test strips.

Authors:  Xue Wang; Chao-Hua Xue; Dong Yang; Shun-Tian Jia; Ya-Ru Ding; Lei Lei; Ke-Yi Gao; Tong-Tong Jia
Journal:  RSC Adv       Date:  2021-08-02       Impact factor: 4.036

3.  A Paper-Based Device for Performing Loop-Mediated Isothermal Amplification with Real-Time Simultaneous Detection of Multiple DNA Targets.

Authors:  Youngung Seok; Hyou-Arm Joung; Ju-Young Byun; Hyo-Sung Jeon; Su Jeong Shin; Sanghyo Kim; Young-Beom Shin; Hyung Soo Han; Min-Gon Kim
Journal:  Theranostics       Date:  2017-06-01       Impact factor: 11.556

4.  Highly Sensitive Chemiluminescence-Based Lateral Flow Immunoassay for Cardiac Troponin I Detection in Human Serum.

Authors:  Gyeo-Re Han; Min-Gon Kim
Journal:  Sensors (Basel)       Date:  2020-05-02       Impact factor: 3.576

Review 5.  Nanomaterials for IoT Sensing Platforms and Point-of-Care Applications in South Korea.

Authors:  Seung-Ho Choi; Joon-Seok Lee; Won-Jun Choi; Jae-Woo Seo; Seon-Jin Choi
Journal:  Sensors (Basel)       Date:  2022-01-13       Impact factor: 3.576

  5 in total