Literature DB >> 27193081

Percutaneous transcatheter aortic valve implantation for degenerated surgical bioprostheses: the first case series in Asia with one-year follow-up.

Paul Toon-Lim Chiam1,2, See-Hooi Ewe3, Jia-Lin Soon4, Kay-Woon Ho3, Yong-Koong Sin4,5, Swee-Yaw Tan3, Soo-Teik Lim3,5, Tian-Hai Koh3,5, Yeow-Leng Chua4,5.   

Abstract

INTRODUCTION: Percutaneous transcatheter aortic valve implantation (TAVI) has become an established therapy for inoperable and high-surgical-risk patients with severe aortic stenosis. Although TAVI in patients with degenerated surgical aortic bioprostheses (i.e. valve-in-valve TAVI) is increasingly reported in Western studies, such data is lacking in Asian patients. We describe the initial experience of valve-in-valve TAVI in Asia.
METHODS: Eight patients who underwent valve-in-valve TAVI due to degenerated aortic bioprostheses were enrolled. The mechanism of bioprosthetic valve failure was stenotic, regurgitation or mixed. All procedures were performed via transfemoral arterial access, using the self-expanding CoreValve prosthesis or balloon-expandable SAPIEN XT prosthesis.
RESULTS: The mean age of the patients was 71.6 ± 13.2 years and five were male. Mean duration to surgical bioprosthesis degeneration was 10.2 ± 4.1 years. Valve-in-valve TAVI was successfully performed in all patients. CoreValve and SAPIEN XT prostheses were used in six and two patients, respectively. There were no deaths, strokes or permanent pacemaker requirement at 30 days, with one noncardiac mortality at one year. All patients experienced New York Heart Association functional class improvement. Post-procedure mean pressure gradients were 20 ± 11 mmHg and 22 ± 8 mmHg at 30 days and one year, respectively. Residual aortic regurgitation (AR) of more than mild severity occurred in one patient at 30 days. At one year, only one patient had mild residual AR.
CONCLUSION: In our experience of valve-in-valve TAVI, procedural success was achieved in all patients without adverse events at 30 days. Good clinical and haemodynamic outcomes were sustained at one year.
Copyright © Singapore Medical Association.

Entities:  

Keywords:  aortic regurgitation; aortic stenosis; bioprosthesis; transcatheter aortic valve implantation; transcatheter aortic valve replacement

Mesh:

Year:  2016        PMID: 27193081      PMCID: PMC4958718          DOI: 10.11622/smedj.2016097

Source DB:  PubMed          Journal:  Singapore Med J        ISSN: 0037-5675            Impact factor:   1.858


  14 in total

Review 1.  Hemodynamic and clinical impact of prosthesis-patient mismatch in the aortic valve position and its prevention.

Authors:  P Pibarot; J G Dumesnil
Journal:  J Am Coll Cardiol       Date:  2000-10       Impact factor: 24.094

2.  Valve-in-valve transcatheter aortic valve implantation for degenerated bioprosthetic heart valves.

Authors:  Holger Eggebrecht; Ulrich Schäfer; Hendrik Treede; Peter Boekstegers; Jörg Babin-Ebell; Markus Ferrari; Helge Möllmann; Helmut Baumgartner; Thierry Carrel; Philipp Kahlert; Philipp Lange; Thomas Walther; Raimund Erbel; Rajendra H Mehta; Matthias Thielmann
Journal:  JACC Cardiovasc Interv       Date:  2011-11       Impact factor: 11.195

3.  Recommendations for evaluation of prosthetic valves with echocardiography and doppler ultrasound: a report From the American Society of Echocardiography's Guidelines and Standards Committee and the Task Force on Prosthetic Valves, developed in conjunction with the American College of Cardiology Cardiovascular Imaging Committee, Cardiac Imaging Committee of the American Heart Association, the European Association of Echocardiography, a registered branch of the European Society of Cardiology, the Japanese Society of Echocardiography and the Canadian Society of Echocardiography, endorsed by the American College of Cardiology Foundation, American Heart Association, European Association of Echocardiography, a registered branch of the European Society of Cardiology, the Japanese Society of Echocardiography, and Canadian Society of Echocardiography.

Authors:  William A Zoghbi; John B Chambers; Jean G Dumesnil; Elyse Foster; John S Gottdiener; Paul A Grayburn; Bijoy K Khandheria; Robert A Levine; Gerald Ross Marx; Fletcher A Miller; Satoshi Nakatani; Miguel A Quiñones; Harry Rakowski; L Leonardo Rodriguez; Madhav Swaminathan; Alan D Waggoner; Neil J Weissman; Miguel Zabalgoitia
Journal:  J Am Soc Echocardiogr       Date:  2009-09       Impact factor: 5.251

4.  Two-year outcomes after transcatheter or surgical aortic-valve replacement.

Authors:  Susheel K Kodali; Mathew R Williams; Craig R Smith; Lars G Svensson; John G Webb; Raj R Makkar; Gregory P Fontana; Todd M Dewey; Vinod H Thourani; Augusto D Pichard; Michael Fischbein; Wilson Y Szeto; Scott Lim; Kevin L Greason; Paul S Teirstein; S Chris Malaisrie; Pamela S Douglas; Rebecca T Hahn; Brian Whisenant; Alan Zajarias; Duolao Wang; Jodi J Akin; William N Anderson; Martin B Leon
Journal:  N Engl J Med       Date:  2012-03-26       Impact factor: 91.245

5.  Transcatheter aortic-valve replacement for inoperable severe aortic stenosis.

Authors:  Raj R Makkar; Gregory P Fontana; Hasan Jilaihawi; Samir Kapadia; Augusto D Pichard; Pamela S Douglas; Vinod H Thourani; Vasilis C Babaliaros; John G Webb; Howard C Herrmann; Joseph E Bavaria; Susheel Kodali; David L Brown; Bruce Bowers; Todd M Dewey; Lars G Svensson; Murat Tuzcu; Jeffrey W Moses; Matthew R Williams; Robert J Siegel; Jodi J Akin; William N Anderson; Stuart Pocock; Craig R Smith; Martin B Leon
Journal:  N Engl J Med       Date:  2012-03-26       Impact factor: 91.245

6.  Transcatheter aortic-valve replacement with a self-expanding prosthesis.

Authors:  David H Adams; Jeffrey J Popma; Michael J Reardon
Journal:  N Engl J Med       Date:  2014-09-04       Impact factor: 91.245

7.  Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document.

Authors:  A Pieter Kappetein; Stuart J Head; Philippe Généreux; Nicolo Piazza; Nicolas M van Mieghem; Eugene H Blackstone; Thomas G Brott; David J Cohen; Donald E Cutlip; Gerrit-Anne van Es; Rebecca T Hahn; Ajay J Kirtane; Mitchell W Krucoff; Susheel Kodali; Michael J Mack; Roxana Mehran; Josep Rodés-Cabau; Pascal Vranckx; John G Webb; Stephan Windecker; Patrick W Serruys; Martin B Leon
Journal:  Eur Heart J       Date:  2012-10       Impact factor: 29.983

8.  Long-term safety and effectiveness of mechanical versus biologic aortic valve prostheses in older patients: results from the Society of Thoracic Surgeons Adult Cardiac Surgery National Database.

Authors:  J Matthew Brennan; Fred H Edwards; Yue Zhao; Sean O'Brien; Michael E Booth; Rachel S Dokholyan; Pamela S Douglas; Eric D Peterson
Journal:  Circulation       Date:  2013-03-28       Impact factor: 29.690

9.  Transcatheter aortic valve replacement using a self-expanding bioprosthesis in patients with severe aortic stenosis at extreme risk for surgery.

Authors:  Jeffrey J Popma; David H Adams; Michael J Reardon; Steven J Yakubov; Neal S Kleiman; David Heimansohn; James Hermiller; G Chad Hughes; J Kevin Harrison; Joseph Coselli; Jose Diez; Ali Kafi; Theodore Schreiber; Thomas G Gleason; John Conte; Maurice Buchbinder; G Michael Deeb; Blasé Carabello; Patrick W Serruys; Sharla Chenoweth; Jae K Oh
Journal:  J Am Coll Cardiol       Date:  2014-03-19       Impact factor: 24.094

10.  Transcatheter aortic valve implantation in failed bioprosthetic surgical valves.

Authors:  Danny Dvir; John G Webb; Sabine Bleiziffer; Miralem Pasic; Ron Waksman; Susheel Kodali; Marco Barbanti; Azeem Latib; Ulrich Schaefer; Josep Rodés-Cabau; Hendrik Treede; Nicolo Piazza; David Hildick-Smith; Dominique Himbert; Thomas Walther; Christian Hengstenberg; Henrik Nissen; Raffi Bekeredjian; Patrizia Presbitero; Enrico Ferrari; Amit Segev; Arend de Weger; Stephan Windecker; Neil E Moat; Massimo Napodano; Manuel Wilbring; Alfredo G Cerillo; Stephen Brecker; Didier Tchetche; Thierry Lefèvre; Federico De Marco; Claudia Fiorina; Anna Sonia Petronio; Rui C Teles; Luca Testa; Jean-Claude Laborde; Martin B Leon; Ran Kornowski
Journal:  JAMA       Date:  2014-07       Impact factor: 56.272

View more
  6 in total

1.  Transfemoral transcatheter tricuspid valve replacement of a degenerated tricuspid bioprosthesis: Initial experience in Southeast Asia with three-year follow-up.

Authors:  Paul Tl Chiam; Yean Teng Lim; Choon Pin Lim; Poo Sing Wong; Yeow Leng Chua
Journal:  Singapore Med J       Date:  2020-11       Impact factor: 1.858

2.  Changes in the practice of cardiology: therapies at the forefront of science.

Authors:  Joshua Ping-Yun Loh; Kian-Keong Poh
Journal:  Singapore Med J       Date:  2016-07       Impact factor: 1.858

3.  Transcatheter aortic valve implantation: from revolution to evolution.

Authors:  Edgar Lik Wui Tay; Kian-Keong Poh; James Wei Luen Yip; William Kf Kong
Journal:  Singapore Med J       Date:  2016-07       Impact factor: 1.858

4.  Percutaneous transfemoral transcatheter mitral valve replacement of a degenerated mitral bioprosthesis: initial experience in Southeast Asia with nine-month follow-up.

Authors:  Paul Toon Lim Chiam; Yean Teng Lim; Choon Pin Lim; Cumaraswamy Sivathasan
Journal:  Singapore Med J       Date:  2020-03-09       Impact factor: 1.858

5.  Transcatheter aortic valve implantation in Asia.

Authors:  Jimmy Kim Fatt Hon; Edgar Tay
Journal:  Ann Cardiothorac Surg       Date:  2017-09

6.  Failed TAVI in TAVI Implantation: TAVI Dislocation Followed by Ensuing Surgical Graft Resection.

Authors:  Róbert Novotný; Jaroslav Hlubocký; Tomáš Kovárník; Petr Mitáš; Zuzana Hlubocka; Jan Rulíšek; Sevim Ismihan Gulmez; Shubjiwan Kaur Ghotra; Jaroslav Lindner
Journal:  Case Rep Cardiol       Date:  2017-04-30
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.