Literature DB >> 27192461

Diagnostic Performance of Self-navigated Whole-Heart Contrast-enhanced Coronary 3-T MR Angiography.

Yi He1, Jianing Pang1, Qinyi Dai1, Zhanming Fan1, Jing An1, Debiao Li1.   

Abstract

Purpose To evaluate the diagnostic performance of self-navigated whole-heart coronary 3-T magnetic resonance (MR) angiography by using conventional invasive coronary angiography (ICA) as the reference gold standard. Materials and Methods This study was approved by the local ethics committee. Written informed consent was obtained from each patient before the study. Thirty-nine consecutive patients underwent coronary MR angiography and later underwent ICA. Coronary MR angiography was performed with a 3-T imager with contrast agent enhancement during free breathing with self-navigated affine motion correction reconstruction. Coronary segments with reference diameters larger than 1.5 mm were included in the comparison between coronary MR angiography and ICA. The coronary MR angiography images were evaluated by two experienced readers blinded to the ICA results to identify significant luminal narrowing (>50% diameter reduction in reference ICA). Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were performed to detect significant coronary artery stenosis. Results Coronary MR angiography examinations were successfully performed in all 39 patients. A total of 327 coronary segments had reference luminal diameter larger than 1.5 mm. Of these 327 coronary segments, 303 (92.7%) segments had a quality score greater than 1 at coronary MR angiography and were included in the analysis. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were 78.2%, 75.0%, 81.8%, 70.6%, and 76.9%, respectively, on a per-patient basis. Conclusion Contrast-enhanced self-navigated coronary 3-T MR angiography is a promising technique for the noninvasive detection of clinically significant coronary stenosis. © RSNA, 2016.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27192461     DOI: 10.1148/radiol.2016152514

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  9 in total

Review 1.  Update on the Role of Cardiac Magnetic Resonance Imaging in Congenital Heart Disease.

Authors:  Prabhakar Rajiah; Animesh Tandon; Gerald F Greil; Suhny Abbara
Journal:  Curr Treat Options Cardiovasc Med       Date:  2017-01

2.  Coronary artery assessment using self-navigated free-breathing radial whole-heart magnetic resonance angiography in patients with congenital heart disease.

Authors:  Moritz H Albrecht; Akos Varga-Szemes; U Joseph Schoepf; Georg Apfaltrer; Jiaqian Xu; Kwang-Nam Jin; Anthony M Hlavacek; Shahryar M Chowdhury; Pal Suranyi; Christian Tesche; Carlo N De Cecco; Davide Piccini; Matthias Stuber; Giulia Ginami; Thomas J Vogl; Arni Nutting
Journal:  Eur Radiol       Date:  2017-09-08       Impact factor: 5.315

3.  Improved respiratory self-navigation for 3D radial acquisitions through the use of a pencil-beam 2D-T2 -prep for free-breathing, whole-heart coronary MRA.

Authors:  Andrew J Coristine; Jerome Chaptinel; Giulia Ginami; Gabriele Bonanno; Simone Coppo; Ruud B van Heeswijk; Davide Piccini; Matthias Stuber
Journal:  Magn Reson Med       Date:  2017-05-31       Impact factor: 4.668

4.  Additive value of 3T cardiovascular magnetic resonance coronary angiography for detecting coronary artery disease.

Authors:  Lijun Zhang; Xiantao Song; Li Dong; Jianan Li; Ruiyu Dou; Zhanming Fan; Jing An; Debiao Li
Journal:  J Cardiovasc Magn Reson       Date:  2018-04-30       Impact factor: 5.364

5.  Can visual analogue scale be used in radiologic subjective image quality assessment?

Authors:  Kathrine Rydén Suther; Einar Hopp; Bjarne Smevik; Arnt Eltvedt Fiane; Harald Lauritz Lindberg; Stig Larsen; Charlotte de Lange
Journal:  Pediatr Radiol       Date:  2018-07-04

6.  Clinical comparison of sub-mm high-resolution non-contrast coronary CMR angiography against coronary CT angiography in patients with low-intermediate risk of coronary artery disease: a single center trial.

Authors:  Reza Hajhosseiny; Imran Rashid; Aurélien Bustin; Camila Munoz; Gastao Cruz; Muhummad Sohaib Nazir; Karine Grigoryan; Tevfik F Ismail; Rebecca Preston; Radhouene Neji; Karl Kunze; Reza Razavi; Amedeo Chiribiri; Pier Giorgio Masci; Ronak Rajani; Claudia Prieto; René M Botnar
Journal:  J Cardiovasc Magn Reson       Date:  2021-05-17       Impact factor: 5.364

7.  High relaxivity Gd3+-based organic nanoparticles for efficient magnetic resonance angiography.

Authors:  Zhuang Liu; Menglong Zhao; Han Wang; Zi Fu; Hongbo Gao; Weijun Peng; Dalong Ni; Wei Tang; Yajia Gu
Journal:  J Nanobiotechnology       Date:  2022-03-31       Impact factor: 10.435

8.  Diagnostic performance of image navigated coronary CMR angiography in patients with coronary artery disease.

Authors:  Markus Henningsson; Joy Shome; Konstantinos Bratis; Miguel Silva Vieira; Eike Nagel; Rene M Botnar
Journal:  J Cardiovasc Magn Reson       Date:  2017-09-11       Impact factor: 5.364

Review 9.  Hybrid cardiac imaging using PET/MRI: a joint position statement by the European Society of Cardiovascular Radiology (ESCR) and the European Association of Nuclear Medicine (EANM).

Authors:  Felix Nensa; Fabian Bamberg; Christoph Rischpler; Leon Menezes; Thorsten D Poeppel; Christian la Fougère; Dietrich Beitzke; Sazan Rasul; Christian Loewe; Konstantin Nikolaou; Jan Bucerius; Andreas Kjaer; Matthias Gutberlet; Niek H Prakken; Rozemarijn Vliegenthart; Riemer H J A Slart; Stephan G Nekolla; Martin L Lassen; Bernd J Pichler; Thomas Schlosser; Alexis Jacquier; Harald H Quick; Michael Schäfers; Marcus Hacker
Journal:  Eur Radiol       Date:  2018-05-02       Impact factor: 5.315

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.