| Literature DB >> 27192179 |
Leena Korpinen1, Harri Kuisti2, Jarmo Elovaara2.
Abstract
The aim of the study was to analyze all values of electric currents from measured periods while performing tasks in forest clearing. The objective was also to choose and analyze measurement cases, where current measurements successfully lasted the entire work period (about 30 min). Two forestry workers volunteered to perform four forest clearing tasks under 400 kV power lines. The sampling frequency of the current measurements was 1 sample/s. The maximum values of the current densities were 1.0-1.2 mA/m(2) (calculated internal EFs 5.0-12.0 mV/m), and the average values were 0.2-0.4 mA/m(2) . The highest contact current was 167.4 μA. All measured values during forest clearing tasks were lower than basic restrictions (0.1 V/m and 0.8 V/m) of the International Commission on Non-Ionizing Radiation Protection. Bioelectromagnetics. 37:423-428, 2016.Entities:
Keywords: current density; forest clearing; forestry workers; power line; total contact current
Mesh:
Year: 2016 PMID: 27192179 PMCID: PMC5084735 DOI: 10.1002/bem.21980
Source DB: PubMed Journal: Bioelectromagnetics ISSN: 0197-8462 Impact factor: 2.010
Figure 1Photo of forest clearing task (A) in place I (first measurement day).
Figure 2Measured currents in the head and total contact currents during forest clearing task A.
Measured Maximum and Average Currents in Head, Measured Maximum and Average Values of Total Contact Currents, Calculated Average Current Densities in Neck, and Calculated Maximum Internal EF at Tasks A–D Under 400 kV Power Lines
| Current in head | Total contact current | Current density in neck | Internal electric field | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Task | n | Max (µA) | Ave (µA) | SD (µA) | n | Max (µA) | Ave (µA) | SD (µA) | Max (mA/m2) | Ave (mA/m2) | SD (mA/m2) | Max (mV/m) |
| A | 1272 | 9.2 | 3.2 | 1.6 | 1271 | 107.1 | 13.7 | 8.4 | 1.0 | 0.4 | 0.2 | 5.0–10.0 |
| B | 1804 | 12.4 | 3.3 | 2.5 | 1804 | 167.4 | 18.9 | 17.6 | 1.2 | 0.3 | 0.3 | 6.0–12.0 |
| C | 1890 | 9.7 | 2.5 | 1.9 | 1890 | 49.9 | 12.2 | 9.3 | 1.0 | 0.2 | 0.2 | 5.0–10.0 |
| D | 1849 | 11.0 | 2.0 | 1.4 | 1849 | 110.8 | 11.7 | 11.3 | 1.1 | 0.2 | 0.1 | 5.5–11.0 |
A: Forest clearing task in place I (first measurement day). B: Forest clearing task in place II using filter (second measurement day). C: Forest clearing task in place II using filter (third measurement day). D: Forest clearing task in place II using filter (third measurement day).
Figure 3Measured currents in the head and total contact currents during forest clearing task B.
Figure 4Measured currents in the head and total contact currents during forest clearing task C.
Figure 5Measured currents in the head and total contact currents during forest clearing task D.