Girish H Vasanad1, S M Antin2, R C Akkimaradi1, Prasad Policepatil3, Girish Naikawadi1.   

Abstract

INTRODUCTION: Lower tibial extra-articular fractures of lower tibial extra-articular bone, treated with Minimally Invasive Percutaneous plate osteosynthesis (MIPPO) may have certain advantages, though the modiality is technically demanding. AIM: To assess the results of distal tibial fractures treated with minimally invasive plate osteosynthesis utilizing precontoured dital medial tibial locking plates without fibular fracture fixation.
MATERIAL AND METHODS: The study was conducted during the period from june 2009 to june 2011. A series of 30 patients (22 men and 8 women) with concurrent distal tibia and fibula fractures who underwent minimally plate osteosynthesis utilizing precontoured distal tibial medial locking plates without fibular fracture fixation have been reviewed after surgery. 14 fractures were type A1, 6 type A2, and 4 type A3. Open Grade II fracture were 4 and Open Grade IIIA fracture is2.
RESULTS: The mean follow-up duration was 2 years. The mean time to bone union was 20 weeks. No patient had shortening, hardware breakdown, or deep-seated infection. Out of 30 patients, 24 had excellent results, 6 had good results. Four patients had palpable screws, two patient had blisters which subsidized with conservative treatment. This minimally invasive technique for treatment of distal tibial fractures proved to be a feasible and worthwhile method of stabilization.
CONCLUSION: It appears from our study that fibula fixation is not required in non-syndesmotic distal metaphyseal extra articular fractures when fixed by locking plate using minimal invasive techniques.

Entities:  

Keywords:  Distal tibial fractures; Fibular fixation; Minimally invasive technique

Year:  2016        PMID: 27190908      PMCID: PMC4866206          DOI: 10.7860/JCDR/2016/7249.7833

Source DB:  PubMed          Journal:  J Clin Diagn Res        ISSN: 0973-709X


  24 in total

1.  Some applications of the functional anatomy of the ankle joint.

Authors:  J R CLOSE
Journal:  J Bone Joint Surg Am       Date:  1956-07       Impact factor: 5.284

2.  Dynamic fibular function: a new concept.

Authors:  P E Scranton; J G McMaster; E Kelly
Journal:  Clin Orthop Relat Res       Date:  1976 Jul-Aug       Impact factor: 4.176

3.  Fractures of the lower end of the tibia into the ankle joint: results 9 years after open reduction and internal fixation.

Authors:  T Rüedi
Journal:  Injury       Date:  1973-11       Impact factor: 2.586

4.  The weight-bearing function of the fibula. A strain gauge study.

Authors:  K L Lambert
Journal:  J Bone Joint Surg Am       Date:  1971-04       Impact factor: 5.284

5.  Complicated open fractures of the distal tibia treated by secondary interlocking nailing.

Authors:  C C Wu; C H Shih
Journal:  J Trauma       Date:  1993-06

6.  The role of the interosseous membrane on tibiofibular weightbearing.

Authors:  J S Skraba; A S Greenwald
Journal:  Foot Ankle       Date:  1984 May-Jun

7.  External fixation of tibial plafond fractures: is routine plating of the fibula necessary?

Authors:  T M Williams; J L Marsh; J V Nepola; T A DeCoster; S R Hurwitz; S B Bonar
Journal:  J Orthop Trauma       Date:  1998-01       Impact factor: 2.512

8.  The operative treatment of intra-articular fractures of the lower end of the tibia.

Authors:  T P Rüedi; M Allgöwer
Journal:  Clin Orthop Relat Res       Date:  1979 Jan-Feb       Impact factor: 4.176

9.  Distal metaphyseal fractures of the tibia with minimal involvement of the ankle. Classification and treatment by locked intramedullary nailing.

Authors:  C M Robinson; G J McLauchlan; I P McLean; C M Court-Brown
Journal:  J Bone Joint Surg Br       Date:  1995-09

10.  Open reduction and internal fixation of tibial plafond fractures. Variables contributing to poor results and complications.

Authors:  S M Teeny; D A Wiss
Journal:  Clin Orthop Relat Res       Date:  1993-07       Impact factor: 4.176

View more
  2 in total

1.  External fixator combined with three different fixation methods of fibula for treatment of extra-articular open fractures of distal tibia and fibula: a retrospective study.

Authors:  Dong-Dong Sun; Dan Lv; Kun Zhou; Jian Chen; Li-Lan Gao; Ming-Lin Sun
Journal:  BMC Musculoskelet Disord       Date:  2021-01-04       Impact factor: 2.362

2.  Effect of Different Reduction Intramedullary Nails on Spiral Fracture of Middle and Lower Tibia.

Authors:  Yongxin Shi; Fuqin Li; Weiguo Liang; Jinshi Liu
Journal:  Contrast Media Mol Imaging       Date:  2022-03-28       Impact factor: 3.161