Temporary leadless pacing in a patient with severe device infection.

Alexander Kypta1, Hermann Blessberger2, Michael Lichtenauer3, Clemens Steinwender2.   

Abstract

A 64-year-old patient underwent implantation of a transcatheter pacing systems (TPS) for severe lead endocarditis. The patient experienced fever after a dental procedure. On the transoesophageal echocardiogram (TEE), vegetations were attached to the leads. Because the patient was pacemaker dependent, a temporary pacing lead had to be placed. After removal, however, he did not improve. A second TEE showed new vegetations. Ventricular fibrillation occurred spontaneously; so isoprenalin had to be stopped and a new lead was implanted. Vegetations appeared soon after the new temporary lead was placed. We used a TPS as a bridging device, followed by implantation of a resynchronisation system, and explantation of the TPS. After the Micra TPS was implanted, the patient recovered noticeably. All inflammation parameters were negative and an additional (18)F-fluorodeoxyglucose-positron emission tomography/CT imaging also proved to be negative. So a CRT-D device was then implanted, and the TCP was removed. 2016 BMJ Publishing Group Ltd.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27190123      PMCID: PMC4885475          DOI: 10.1136/bcr-2016-215724

Source DB:  PubMed          Journal:  BMJ Case Rep        ISSN: 1757-790X


  4 in total

1.  A Leadless Intracardiac Transcatheter Pacing System.

Authors:  Dwight Reynolds; Gabor Z Duray; Razali Omar; Kyoko Soejima; Petr Neuzil; Shu Zhang; Calambur Narasimhan; Clemens Steinwender; Josep Brugada; Michael Lloyd; Paul R Roberts; Venkata Sagi; John Hummel; Maria Grazia Bongiorni; Reinoud E Knops; Christopher R Ellis; Charles C Gornick; Matthew A Bernabei; Verla Laager; Kurt Stromberg; Eric R Williams; J Harrison Hudnall; Philippe Ritter
Journal:  N Engl J Med       Date:  2015-11-09       Impact factor: 91.245

2.  Percutaneous Implantation of an Entirely Intracardiac Leadless Pacemaker.

Authors:  Vivek Y Reddy; Derek V Exner; Daniel J Cantillon; Rahul Doshi; T Jared Bunch; Gery F Tomassoni; Paul A Friedman; N A Mark Estes; John Ip; Imran Niazi; Kenneth Plunkitt; Rajesh Banker; James Porterfield; James E Ip; Srinivas R Dukkipati
Journal:  N Engl J Med       Date:  2015-08-30       Impact factor: 91.245

Review 3.  Infected cardiac-implantable electronic devices: prevention, diagnosis, and treatment.

Authors:  Jens Cosedis Nielsen; Jens Christian Gerdes; Niraj Varma
Journal:  Eur Heart J       Date:  2015-03-05       Impact factor: 29.983

4.  Early performance of a miniaturized leadless cardiac pacemaker: the Micra Transcatheter Pacing Study.

Authors:  Philippe Ritter; Gabor Z Duray; Clemens Steinwender; Kyoko Soejima; Razali Omar; Lluís Mont; Lucas V A Boersma; Reinoud E Knops; Larry Chinitz; Shu Zhang; Calambur Narasimhan; John Hummel; Michael Lloyd; Timothy Alexander Simmers; Andrew Voigt; Verla Laager; Kurt Stromberg; Matthew D Bonner; Todd J Sheldon; Dwight Reynolds
Journal:  Eur Heart J       Date:  2015-06-04       Impact factor: 29.983

  4 in total
  2 in total

Review 1.  [Micra™ leadless pacemaker : Clinical experience and perspectives].

Authors:  Clemens Steinwender; Hermann Blessberger; Daniel Kiblböck; Karim Saleh; Jürgen Kammler
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2018-11-19

2.  Visualization and appearance of artifacts of leadless pacemaker systems in cardiac MRI : An experimental ex vivo study.

Authors:  Christoph Edlinger; Marcel Granitz; Vera Paar; Christian Jung; Alexander Pfeil; Sarah Eder; Bernhard Wernly; Jürgen Kammler; Klaus Hergan; Uta C Hoppe; Clemens Steinwender; Michael Lichtenauer; Alexander Kypta
Journal:  Wien Klin Wochenschr       Date:  2018-05-23       Impact factor: 1.704

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.