Hyun Ah Jeong1, Jeonghee Shin1, Eunji Kim1, Eun Hee Lee1, Byung Min Choi1, Chang Sung Son1, Joo Won Lee1.
Abstract
PURPOSE: This study aimed to evaluate the correlation, according to postnatal age, between plasma B-type natriuretic peptide (BNP) levels and echocardiographic parameters for the assessment of patent ductus arteriosus (PDA) in preterm infants with respiratory distress.Entities:
Keywords: B-type natriuretic peptide; Echocardiography; Patent ductus arteriosus; Premature infant
Year: 2016 PMID: 27186229 PMCID: PMC4865642 DOI: 10.3345/kjp.2016.59.4.183
Source DB: PubMed Journal: Korean J Pediatr ISSN: 1738-1061
Patient characteristics (n=42)
| Variable | Value |
|---|---|
| Gestational age (wk) | 29.9±3.0 |
| Birth weight (g) | 1,503±606 |
| Male sex | 19 (45.2) |
| Use of antenatal steroid | 29 (69.0) |
| Cesarean section | 26 (61.9) |
| Apgar score | |
| At 1 min | 6 (5-7) |
| At 5 min | 8 (7-9) |
| RDS with surfactant therapy | 28 (66.7) |
| Treatment for PDA | |
| Ibuprofen | 23 (54.8) |
| Surgical ligation | 9 (21.4) |
| Respiratory support | 42 (100) |
| Invasive ventilation with endotracheal intubation | 30 (71.4) |
Values are presented as mean±standard deviation, number (%), or median (25th–75th percentile).
RDS, respiratory distress syndrome; PDA, patent ductus arteriosus.
Fig. 1Correlations between B-type natriuretic peptide (BNP) levels and echocardiographic parameters. (A) Correlation between BNP levels and the diameter of the ductus arteriosus (DA; r=0.368, P<0.001). (B) Correlation between BNP levels and the ratio of the patent ductus arteriosus (PDA) diameter to the infant's left pulmonary artery diameter (PDA/LPA ratio; r=0.426, P<0.001). (C) Correlation between BNP levels and the ratio of the left atrial diameter to the aortic diameter (LA/Ao ratio; r=0.412, P<0.001). (D) Correlation between BNP levels and the antegrade diastolic flow of the left pulmonary artery (DFLPA; r=0.418, P<0.001).
Fig. 2Correlations between B-type natriuretic peptide (BNP) levels and echocardiographic parameters according to age. (A) Correlation between BNP levels and the ductus arteriosus diameter according to age; a significant correlation was observed postnatal day 5 onward (r=0.478, P=0.018). (B) Correlation between BNP levels and the PDA/LPA ratio according to age; a significant correlation was observed postnatal day 3 onward (r=0.422, P=0.045). (C) Correlation between BNP levels and the LA/Ao ratio according to age; a significant correlation was observed postnatal day 2 onward (r=0.422, P=0.023). (D) Correlation between BNP levels and the DFLPA according to age; a significant correlation was observed postnatal day 3 onward (r=0.446, P=0.033). PDA/LPA ratio, the ratio of the patent ductus arteriosus diameter to the infant's left pulmonary artery diameter; LA/Ao ratio, the ratio of the left atrial diameter to the aortic diameter; DFLPA, diastolic flow of the left pulmonary artery; PNA, postnatal age.