| Literature DB >> 27184488 |
Alexander Deyneko1, Fernanda Cordeiro1, Laurie Berlin1, Debby Ben-David1,2, Silvana Perna1, Yves Longtin3,4.
Abstract
BACKGROUND: The impact of sink location on hand washing compliance after contact with patients with Clostridium difficile infection (CDI) is poorly understood. The aim of this study is to determine the location of hand wash sinks available to healthcare workers (HCWs) after caring for patients with CDI and to assess the impact on hand washing compliance.Entities:
Keywords: Additional precautions; Clostridium difficile; Epidemiology; Hand hygiene; Handwashing; Sinks
Mesh:
Year: 2016 PMID: 27184488 PMCID: PMC4867524 DOI: 10.1186/s12879-016-1535-x
Source DB: PubMed Journal: BMC Infect Dis ISSN: 1471-2334 Impact factor: 3.090
Characteristics of rooms hosting patients with Clostridium difficile infections, Jewish General Hospital, Canada, April 2012- March 2013
| On the day of diagnosis | 24 h after diagnosis |
| |
|---|---|---|---|
|
|
| ||
| Room type (%) | |||
| Private | 25 (13.7 %) | 76 (45.2 %) | <0.001 |
| 2-bedded room | 114 (62.3 %) | 85 (50.6 %) | 0.04 |
| 3-4-bedded room | 44 (24.0 %) | 7 (4.2 %) | <0.001 |
| Location of the closest available sink for HCW handwash (%) | |||
| Nursing station | 92 (50.3 %) | 79 (47.0 %) | 0.61 |
| Hallway | 78 (42.6 %) | 83 (49.4 %) | 0.24 |
| Medication room | 9 (4.9 %) | 4 (2.4 %) | 0.26 |
| Clean utility room | 2 (1.1 %) | 2 (1.2 %) | 1.00 |
| Other | 2 (1.1 %) | 0 (0 %) | 0.49 |
| Median distance between patient room and closest sink (meters) (IQR) | 11.6 (6.7–18.9) | 12.5 (6.7–23.2) | 0.005 |
| Private room | 9.8 (4.0–22) | 16.2 (6.4–25.6) | 0.21 |
| 2 bedded room | 10.5 (6.3–18.9) | 10.4 (7.0–20.1) | 0.60 |
| 3-4 bedded room | 12.8 (8.2–20.7) | 18.9 (13.4–23.2) | 0.22 |
| Path from room to nearest sink (%) | |||
| Direct line from patient room | 60 (32.8 %) | 62 (36.9 %) | 0.49 |
| One 90° turn required to reach sink | 30 (16.4 %) | 22 (13.1 %) | 0.47 |
| Two or more 90° turns required to reach sink | 93 (50.8 %) | 84 (50.0 %) | 0.96 |
a24 h after diagnosis, 15 patients were excluded as they had been discharged (n = 13) or transferred to a non-study unit (n = 2)
Abbreviation: IQR interquartile range
Factors associated with performance of hand washing after exposure to Clostridium difficile, Jewish General Hospital, Canada, April 2012- March 2013
| Characteristics | Hand washing performed (%) | Hand washing not perfomed (%) |
|
|---|---|---|---|
| Type of healthcare worker | |||
| Nurse | 18/94 (19.1 %) | 76/94 (80.9 %) | ref |
| MD | 2/12 (16.7 %) | 10/12 (83.3 %) | 0.90 |
| Medical resident/student | 6/32 (18.8 %) | 26/32 (81.3 %) | 0.91 |
| Orderly | 3/36 (8.3 %) | 33/36 (91.7 %) | 0.95 |
| Meal service | 0/40 (0 %) | 40/40 (100 %) | 0.24 |
| Othera | 6/33 (18.2 %) | 27/33 (81.8 %) | 0.99 |
| Hand hygiene | |||
| Hand rubbing alone | 0/82 (0 %) | 82/82 (100 %) | n/a |
| Hand washing alone | 24/24 (100 %) | 0/24 (0 %) | n/a |
| Hand rubbing followed by hand washing | 11/11 (100 %) | 0/11 (0 %) | n/a |
| None performed | 0/130 (0 %) | 130/130 (100 %) | n/a |
| Glove use | |||
| Glove use while caring for patient | 35/211 (16.6 %) | 176/211 (83.4 %) | ref |
| No glove use while caring for patients | 0/36 (0 %) | 36/36 (100 %) | 0.02 |
| Glove removalb | |||
| Proper timing of glove removal after leaving patient zoneb | 35/160 (21.9 %) | 125/160 (78.1 %) | Ref |
| Improper timing of glove removal after leaving patient zoneb | 0/51 (0 %) | 51/51 (100 %) | <0.001 |
| Location of nearest available sink | |||
| Hallway | 19/70 (27.1 %) | 51/70 (72.9 %) | Ref |
| Nursing station | 9/129 (7.0 %) | 120/129 (93.0 %) | 0.23 |
| Medication room | 4/28 (14.3 %) | 24/28 (85.7 %) | 0.27 |
| Other | 3/20 (15.0 %) | 17/20 (85.0 %) | 0.95 |
| Median distance to sink (IQR) | 7.6 (4.3–12.5) | 14.9 (10.4–23.4) | <0.001 |
| Number of turns required to reach sink | |||
| None | 21/82 (25.6 %) | 61/82 (74.4 %) | Ref |
| One 90° turn | 8/49 (16.3 %) | 41/49 (83.7 %) | 0.22 |
| Two 90° turns | 6/71 (8.5 %) | 65/71 (91.5 %) | 0.008 |
| ≥ Three 90o turns | 0/45 (0 %) | 45/45 (100 %) | 0.006 |
| Visualization of sink from patient zone | |||
| Sink within direct sight from patient room | 21/82 (25.6 %) | 61/82 (74.4 %) | Ref |
| Sink not in direct sight from patient room | 14/165 (8.5 %) | 151/165 (91.5 %) | <0.001 |
Abbreviations: IQR interquartile range, n/a not applicable, Ref reference
aIncludes occupational therapist, physiotherapist, radiology technician, pharmacist
bOnly among 211 healthcare workers who wore gloves while in the room
Factors associated with hand washing following Clostridium difficile exposure by multivariate analysis, Jewish General Hospital, Canada, April 2012- March 2013
| Characteristic | Adjusted OR | 95 % CI |
|
|---|---|---|---|
| Proper timing of glove removal upon exiting patient zone | 14.87 | 1.93–114.43 | 0.01 |
| Distance between patient zone and sink | 0.90 | 0.84–0.97 | 0.008 |
| Number of 90° turns to reach the sink | 0.78 | 0.44–1.37 | 0.78 |
Analysis performed on 211 hand hygiene observations. Only observations during which healthcare workers wore gloves were included in the analysis. 36 observations (15 %) were excluded from the analysis due to missing data
Abbreviations: OR odds ratio, CI confidence interval