Literature DB >> 27181645

Chelate titrations of Ca(2+) and Mg(2+) using microfluidic paper-based analytical devices.

Shingo Karita1, Takashi Kaneta2.   

Abstract

We developed microfluidic paper-based analytical devices (μPADs) for the chelate titrations of Ca(2+) and Mg(2+) in natural water. The μPAD consisted of ten reaction zones and ten detection zones connected through narrow channels to a sample zone located at the center. Buffer solutions with a pH of 10 or 13 were applied to all surfaces of the channels and zones. Different amounts of ethylenediaminetetraacetic acid (EDTA) were added to the reaction zones and a consistent amount of a metal indicator (Eriochrome Black T or Calcon) was added to the detection zones. The total concentrations of Ca(2+) and Mg(2+) (total hardness) in the water were measured using a μPAD containing a buffer solution with a pH of 10, whereas only Ca(2+) was titrated using a μPAD prepared with a potassium hydroxide solution with a pH of 13. The μPADs permitted the determination of Ca(2+) and Mg(2+) in mineral water, river water, and seawater samples within only a few minutes using only the naked eye-no need of instruments.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Calcium; Chelate titration; Hardness; Magnesium; Microfluidic paper-based analytical device; Natural water

Year:  2016        PMID: 27181645     DOI: 10.1016/j.aca.2016.04.019

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  5 in total

1.  Simultaneous Multiplexed Detection of Protein and Metal Ions by a Colorimetric Microfluidic Paper-based Analytical Device.

Authors:  Xiaolu Xiong; Junlin Zhang; Zhou Wang; Chenchen Liu; Wende Xiao; Junfeng Han; Qingfan Shi
Journal:  Biochip J       Date:  2020-10-27       Impact factor: 3.494

2.  Counting-based microfluidic paper-based devices capable of analyzing submicroliter sample volumes.

Authors:  Md Almostasim Mahmud; Eric J M Blondeel; Brendan D MacDonald
Journal:  Biomicrofluidics       Date:  2020-01-10       Impact factor: 2.800

3.  "Dip-and-read" paper-based analytical devices using distance-based detection with color screening.

Authors:  Kentaro Yamada; Daniel Citterio; Charles S Henry
Journal:  Lab Chip       Date:  2018-05-15       Impact factor: 6.799

4.  An Open Software Platform for the Automated Design of Paper-Based Microfluidic Devices.

Authors:  Nicholas S DeChiara; Daniel J Wilson; Charles R Mace
Journal:  Sci Rep       Date:  2017-11-24       Impact factor: 4.379

Review 5.  Recent Advances in Microfluidic Paper-Based Analytical Devices toward High-Throughput Screening.

Authors:  Siraprapa Boobphahom; Mai Nguyet Ly; Veasna Soum; Nayoon Pyun; Oh-Sun Kwon; Nadnudda Rodthongkum; Kwanwoo Shin
Journal:  Molecules       Date:  2020-06-28       Impact factor: 4.411

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.