Radiation dose reduction in cardiovascular CT angiography with iterative reconstruction (AIDR 3D) in a swine model: a model of paediatric cardiac imaging.

Pengfei Zhao1, Yang Hou1, Qin Liu1, Yue Ma1, Qiyong Guo2.   

Abstract

AIM: To investigate the potential dose reduction in cardiovascular computed tomography angiography (CTA) in a swine model using 320-detector volume CT with adaptive iterative dose reduction in three dimensions (AIDR 3D) reconstruction to maintain a comparable image quality (IQ) to that reconstructed by a conventional filtered back projection (FBP) algorithm. METHODS AND MATERIALS: Twenty-four mini-pigs underwent cardiovascular CTA four times at 80 KVp and different tube currents. An automatic exposure control (AEC) system was used and the noise index (NI) was predetermined at a standard deviation (SD) of 20 (Method A, routine dose), and 25, 30, 35 (Methods B-D) to reduce the dose gradually. Method A was reconstructed with FBP. Methods B-D were reconstructed using AIDR 3D (strong). Two radiologists graded IQ by reviewing both cardiac and vascular structures using a five-point scale. Quantitative IQ parameters of image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were measured and compared. A receiver-operating characteristic (ROC) analysis was performed to select a radiation reduction threshold and maintain comparable IQ (score ≥4).
RESULTS: Method B and C had significantly lower image noise (p<0.0001), higher CNR and SNR than Method A (p<0.0001). Compared with Method A (noise: 52.7±8.3; SNR: 11.7±2.8; and CNR: 9.9±2.7), Method C had comparable subjective IQ and higher objective IQ (noise: 38.9±6.1; SNR: 16.3±3.5; and CNR: 13.5±3.3). The results of the ROC curve showed that Method C (SD30) was the optimal dose threshold to maintain a comparable subjective IQ (AUC: 0.85, 95% confidence interval [CI]: 0.80-0.90). The effective dose (ED) of Method C was reduced by 49%, compared to that of Method A (0.33±0.08 mSv versus 0.65±0.15 mSv).
CONCLUSION: AIDR 3D at a strong level combined with an AEC system can potentially reduce the ED by 49% and maintain an IQ comparable to that achieved using a routine-dose and FBP reconstruction in mini-pig cardiovascular CTA.
Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2016        PMID: 27180082     DOI: 10.1016/j.crad.2016.04.016

Source DB:  PubMed          Journal:  Clin Radiol        ISSN: 0009-9260            Impact factor:   2.350


  3 in total

1.  Potential increase in radiation-induced DNA double-strand breaks with higher doses of iodine contrast during coronary CT angiography.

Authors:  Toon Van Cauteren; Kaoru Tanaka; Dries Belsack; Gert Van Gompel; Veerle Kersemans; Kristin Jochmans; Steven Droogmans; Johan de Mey; Nico Buls
Journal:  Med Phys       Date:  2021-10-13       Impact factor: 4.506

2.  Deep learning reconstruction versus iterative reconstruction for cardiac CT angiography in a stroke imaging protocol: reduced radiation dose and improved image quality.

Authors:  Angélique Bernard; Pierre-Olivier Comby; Brivaël Lemogne; Karim Haioun; Frédéric Ricolfi; Olivier Chevallier; Romaric Loffroy
Journal:  Quant Imaging Med Surg       Date:  2021-01

3.  Application value of iterative reconstruction with CTA to intractable headache patients.

Authors:  Yanfeng Xu; Shujing Yu; Li Zhang; Jing Zheng; Yuefeng Chen; Yanxu Che
Journal:  Exp Ther Med       Date:  2018-05-29       Impact factor: 2.447

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.