Literature DB >> 2717753

Intracranial circulation: pulse-sequence considerations in three-dimensional (volume) MR angiography.

P M Ruggieri1, G A Laub, T J Masaryk, M T Modic.   

Abstract

The technique and feasibility of magnetic resonance (MR) angiography of intracranial vessels were studied in 35 healthy volunteers. Variations in image orientation, repetition time (TR), and flip angle were evaluated to determine their effects on flow-related enhancement. Gradient modifications--including echo time (TE), motion compensation, bandwidth, and field of view--were also studied in an effort to reduce motion-induced phase shifts. Results indicated that a FISP (fast imaging with steady precession) sequence with a TR of 50 msec, TE of 15 msec, velocity compensation in the read and section-select directions, acceleration compensation in the read direction, anisotropic volume, and a 1.25-mm partition thickness produced three-dimensional angiographic MR images that were accurate and reproducible in the depiction of the major intracranial vessels. Difficulties with field of view, persistent signal void secondary to higher-order motion, and spatial resolution remain major problems requiring additional study.

Mesh:

Year:  1989        PMID: 2717753     DOI: 10.1148/radiology.171.3.2717753

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  21 in total

Review 1.  Brain imaging.

Authors:  R I Grossman
Journal:  AJNR Am J Neuroradiol       Date:  2000-01       Impact factor: 3.825

2.  Basic principles of magnetic resonance angiography.

Authors:  R R Edelman
Journal:  Cardiovasc Intervent Radiol       Date:  1992 Jan-Feb       Impact factor: 2.740

3.  Selective magnetic resonance angiography of the head.

Authors:  H P Mattle; K U Wentz
Journal:  Cardiovasc Intervent Radiol       Date:  1992 Jan-Feb       Impact factor: 2.740

4.  Instrumentation for magnetic resonance angiography.

Authors:  D Saloner; C M Anderson
Journal:  Cardiovasc Intervent Radiol       Date:  1992 Jan-Feb       Impact factor: 2.740

5.  Usefulness of two-dimensional time-of-flight MR angiography combined with surface anatomy scanning for convexity lesions.

Authors:  B Pant; M Sumida; K Kurisu; K Arita; F Ikawa; K Migita; M Kutsuna; T Uozumi
Journal:  Neurosurg Rev       Date:  1997       Impact factor: 3.042

6.  Magnetic resonance angiographic and clinical features of extracranial vertebral artery dissection.

Authors:  A Auer; S Felber; C Schmidauer; P Waldenberger; F Aichner
Journal:  J Neurol Neurosurg Psychiatry       Date:  1998-04       Impact factor: 10.154

7.  Aneurysms of the anterior communicating artery treated with Guglielmi detachable coils: follow-up with contrast-enhanced MR angiography.

Authors:  Xavier Leclerc; Jean-François Navez; Jean-Yves Gauvrit; Jean-Paul Lejeune; Jean-Pierre Pruvo
Journal:  AJNR Am J Neuroradiol       Date:  2002-08       Impact factor: 3.825

8.  MR imaging and angiography in tuberculous meningitis.

Authors:  R K Gupta; S Gupta; D Singh; B Sharma; A Kohli; R B Gujral
Journal:  Neuroradiology       Date:  1994       Impact factor: 2.804

9.  Magnetic resonance imaging and angiography in hemifacial spasm.

Authors:  S Felber; G Birbamer; F Aichner; W Poewe; A Kampfl
Journal:  Neuroradiology       Date:  1992       Impact factor: 2.804

10.  Intracranial magnetic resonance angiography.

Authors:  P M Ruggieri; T J Masaryk; J S Ross; M T Modic
Journal:  Cardiovasc Intervent Radiol       Date:  1992 Jan-Feb       Impact factor: 2.740

View more