Literature DB >> 2717386

Cervical orthoses.

A Beavis1.   

Abstract

A biomechanical study is presented to compare the effectiveness of three types of off-the-shelf cervical orthoses and one custom-fit collar in restricting cervical spine motion. A group of 10 normal subjects was studied. The measurements of flexion and extension, lateral side flexion and axial rotation were recorded using various measurement techniques. Interface pressures at the chin and occiput were also measured, along with the warming effect of the collars. The results indicated that all the collars restricted neck movements, for example, the Plastazote collar by 50% of flexion and extension, and that there was no significant difference between off-the-shelf Plastazote and custom-fit collars in restricting movement. Significantly high interface pressures were recorded at the chin, with the subjects wearing the hard and Plastazote orthoses. The warming effect of the soft collar was equal to that of a wool scarf. The study was aimed at improving prescription and although the subjective observations were not validated, the subjects concluded that the custom-fit collars were more comfortable; an important point with such a high rejection rate.

Entities:  

Mesh:

Year:  1989        PMID: 2717386     DOI: 10.3109/03093648909079403

Source DB:  PubMed          Journal:  Prosthet Orthot Int        ISSN: 0309-3646            Impact factor:   1.895


  4 in total

1.  Analysis of a customized cervical collar to improve neck posture during smartphone usage: a comparative study in healthy subjects.

Authors:  Yuh-Ruey Kuo; Jing-Jing Fang; Chi-Tse Wu; Ruey-Mo Lin; Pei-Fang Su; Cheng-Li Lin
Journal:  Eur Spine J       Date:  2019-06-05       Impact factor: 3.134

2.  The Effect of the Cervical Orthosis on Swallowing Physiology and Cervical Spine Motion During Swallowing.

Authors:  Kojiro Mekata; Tomoyuki Takigawa; Jun Matsubayashi; Kazukiyo Toda; Yasuhiro Hasegawa; Yasuo Ito
Journal:  Dysphagia       Date:  2015-11-25       Impact factor: 3.438

Review 3.  The measurement of tissue interface pressures and changes in jugular venous parameters associated with cervical immobilisation devices: a systematic review.

Authors:  Alison Sparke; Sarah Voss; Jonathan Benger
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2013-12-03       Impact factor: 2.953

4.  Effectiveness of orthoses for treatment in patients with spinal pain.

Authors:  Yoo Jin Choo; Min Cheol Chang
Journal:  Yeungnam Univ J Med       Date:  2020-03-24