Literature DB >> 27173827

Characterization of three-dimensional anisotropic heart valve tissue mechanical properties using inverse finite element analysis.

Mostafa Abbasi1, Mohammed S Barakat1, Koohyar Vahidkhah1, Ali N Azadani2.   

Abstract

Computational modeling has an important role in design and assessment of medical devices. In computational simulations, considering accurate constitutive models is of the utmost importance to capture mechanical response of soft tissue and biomedical materials under physiological loading conditions. Lack of comprehensive three-dimensional constitutive models for soft tissue limits the effectiveness of computational modeling in research and development of medical devices. The aim of this study was to use inverse finite element (FE) analysis to determine three-dimensional mechanical properties of bovine pericardial leaflets of a surgical bioprosthesis under dynamic loading condition. Using inverse parameter estimation, 3D anisotropic Fung model parameters were estimated for the leaflets. The FE simulations were validated using experimental in-vitro measurements, and the impact of different constitutive material models was investigated on leaflet stress distribution. The results of this study showed that the anisotropic Fung model accurately simulated the leaflet deformation and coaptation during valve opening and closing. During systole, the peak stress reached to 3.17MPa at the leaflet boundary while during diastole high stress regions were primarily observed in the commissures with the peak stress of 1.17MPa. In addition, the Rayleigh damping coefficient that was introduced to FE simulations to simulate viscous damping effects of surrounding fluid was determined.
Copyright © 2016 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Fung constitutive model; Heart valves; Inverse finite element simulation; Medical device; Stress; Three-dimensional anisotropic mechanical properties; Viscous damping coefficient

Mesh:

Year:  2016        PMID: 27173827     DOI: 10.1016/j.jmbbm.2016.04.031

Source DB:  PubMed          Journal:  J Mech Behav Biomed Mater        ISSN: 1878-0180


  4 in total

1.  An improved parameter estimation and comparison for soft tissue constitutive models containing an exponential function.

Authors:  Ankush Aggarwal
Journal:  Biomech Model Mechanobiol       Date:  2017-03-01

2.  Microstructural deformation observed by Mueller polarimetry during traction assay on myocardium samples.

Authors:  Nicole Tueni; Jérémy Vizet; Martin Genet; Angelo Pierangelo; Jean-Marc Allain
Journal:  Sci Rep       Date:  2020-11-25       Impact factor: 4.379

Review 3.  Experimental and computational models for tissue-engineered heart valves: a narrative review.

Authors:  Ge Yan; Yuqi Liu; Minghui Xie; Jiawei Shi; Weihua Qiao; Nianguo Dong
Journal:  Biomater Transl       Date:  2021-12-28

4.  An investigation of the anisotropic mechanical properties and anatomical structure of porcine atrioventricular heart valves.

Authors:  Samuel Jett; Devin Laurence; Robert Kunkel; Anju R Babu; Katherine Kramer; Ryan Baumwart; Rheal Towner; Yi Wu; Chung-Hao Lee
Journal:  J Mech Behav Biomed Mater       Date:  2018-07-18
  4 in total